Beiyu Wang

Dr. Beiyu Wang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
CHCheng-Yi Huang
Cheng-Yi Huang
YMYang Meng
Yang Meng
BWBeiyu Wang
Beiyu Wang
JYJie Yu
Jie Yu
CDChen Ding
Chen Ding
HLHao Liu
Hao Liu
Objectives: To investigate the effect of the difference in C2–7 angle on dysphagia after anterior cervical discectomy and fusion (ACDF) with the Zero-P Implant System. Methods: A retrospective analysis of 181 patients who underwent ACDF with the Zero-P Implant System and had at least one year of follow-up from January 2011 to November 2018 was performed. All patients were divided into a non-dysphagia group and a dysphagia group to explore the effect of the difference between postoperative and preoperative C2–7 angle (dC2–7A) on postoperative dysphagia. At the same time, other possible related factors including the difference between postoperative and preoperative O-C2 angle (dO-C2A), sex, age, body mass index (BMI), intraoperative time, estimated blood loss, diabetes mellitus, hypertension, smoking, alcohol consumption, prevertebral soft-tissue swelling (PSTS), the highest segment involved in the surgery and the levels of surgery segments were analyzed. Results: In total, the non-dysphagia group comprised 139 patients and the dysphagia group comprised 42 patients. The single-factor analysis showed that smoking, PSTS and dC2–7A were significantly different between the two groups (P < 0.05). Spearman’s correlation coefficient showed no significant correlation between the degree of dysphagia and dC2–7A (P > 0.05). The results of the multiple-factor analysis with an ordinal logistic regression model showed that smoking, PSTS and dC2–7A were significantly associated with the incidence of dysphagia (P < 0.05). Conclusions: The postoperative C2–7 angle has an important effect on the occurrence of dysphagia in patients undergoing Zero-P implant system interbody fusion surgery.

29 August 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
HAHaimiti Abudouaini
Haimiti Abudouaini
TWTingkui Wu
Tingkui Wu
YMYang Meng
Yang Meng
CDChen Ding
Chen Ding
HLHao Liu
Hao Liu
BWBeiyu Wang
Beiyu Wang
Introduction: Anterior cervical discectomy and fusion (ACDF) is a most frequently used surgical procedure for treating cervical radiculopathy and myelopathy. However, there is concern about the high adjacent segment degeneration (ASD) rate after ACDF surgery. We creatively designed an elastically deformable cervical implant to reduce the postoperative stress concentration. In this study, we aimed to investigate the biomechanical performance of this novel cervical implant and compare it with the commonly used cervical devices.Methods: Biomechanical test was conducted on twelve fresh-frozen human cadaveric cervical spines (C2–C7) and randomly divided into four groups according to implant types: intact group, Zero-P VA fusion (ACDF) group, the novel cervical implant group and Pretic-I artificial cervical disc (ACDR) group. An optical tracking system was used to evaluate the segmental range of motion (ROM) of the C4/C5, C5/C6, and C6/C7 segments and micro pressure sensor was used to record the maximum facet joint pressure (FJP), maximum intradiscal pressure (IDP) at the C4-5 and C6-7 segments.Results: There were no significant differences in the ROM of adjacent segments between the groups. Compared with the intact group, the ACDR group essentially retained the ROM of the operated segment. The novel cervical implant decrease some ROM of the operated segment, but it was still significantly higher than in the fusion group; The maximum FJP and IDP at the adjacent segments in the ACDF group were significantly higher than those values in the other groups, and there were no differences in the other groups.Conclusion: While the newly developed elastically deformable cervical implant does not completely maintain ROM like the artificial cervical disc, it surpasses the fusion device with regards to biomechanical attributes. After further refinement, this novel implant may be suitable for patients who are prone to severe adjacent segment degeneration after fusion surgery but no indication for artificial cervical disc surgery.

3 February 2022 in Clinical Neurology and Neurosurgery
Verified
Journal Article
Closed access
HAHaimiti Abudouaini
Haimiti Abudouaini
HLHao Liu
Hao Liu
PHPing Huang
Ping Huang
BWBeiyu Wang
Beiyu Wang
TWTingkui Wu
Tingkui Wu
HCHua Chen
Hua Chen