Untethered robots miniaturized to the length scale of millimeter and below attract growing attention for the prospect of transforming many aspects of health care and bioengineering. As the robot size goes down to the order of a single cell, previously inaccessible body sites would become available for high-resolution in situ and in vivo manipulations. This unprecedented direct access would enable an extensive range of minimally invasive medical operations. Here, we provide a comprehensive review of the current advances in biomedical untethered mobile milli/microrobots. We put a special emphasis on the potential impacts of biomedical microrobots in the near future. Finally, we discuss the existing challenges and emerging concepts associated with designing such a miniaturized robot for operation inside a biological environment for biomedical applications.
7 October 2015 in IEEE/ASME Transactions on Mechatronics
This paper introduces a new 5-D localization method for an untethered meso-scale magnetic robot, which is manipulated by a computer-controlled electromagnetic system. The developed magnetic localization setup is a 2D array (8 × 8) of mono-axial Hall-effect sensors, which measure the perpendicular magnetic fields at their given positions. We introduce two steps for localizing a magnetic robot more accurately. First, the dipole-modeled magnetic field of the electromagnet is subtracted from the measured data in order to determine the robot's magnetic field. Second, the subtracted magnetic field is twice differentiated in the perpendicular direction of the array, so that the effect of the electromagnetic field in the localization process is minimized. Five variables regarding the position and orientation of the robot are determined by minimizing the error between the measured magnetic field and the modeled magnetic field in an optimization method. The resulting position error is 2.1 ± 0.8 mm and angular error is 6.7 ± 4.3° within the applicable range (5 cm) of magnetic field sensors at 200 Hz. The proposed localization method would be used for the position feedback control of untethered magnetic devices or robots for medical applications in the future.
In this paper, we propose a compliant and tetherless magnetic capsule endoscopic robot. The proposed capsule robot has two key features. First, it has one extra degree of freedom axial contraction capability to perform additional tasks such as a drug releasing, a drug injection, or a biopsy. Also, design features of the magnetically deformed capsule robot are introduced. Its characteristic deformation curve, which was measured using an indentation setup, presents not only the deformation behavior of the magnetic capsule robot but also considerations in the capsule design process. Next, by implementing a magnetically actuated rolling locomotion scheme, the capsule can be controlled externally using a permanent magnet. The proposed magnetic capsule robot is anchored on a tissue wall by the magnetic attraction and rotated by a magnetic torque. This behavior allows a stable locomotion of the magnetic capsule robot and its orientation is controllable during locomotion. To verify the feasibility of proposed locomotion method and the compliant capsule's shape deformation, the magnetic capsule robot was actuated in a synthetic stomach model. The experimental results show that locomotion behavior of the capsule is stable and a successful tracking performance of the proposed magnetic actuation method; average distance gap between the capsule and the external magnet was only 20% of the capsule's body length. Such a soft and tetherless capsule robot can potentially enable minimally invasive diagnostic and treatment applications for stomach diseases.
11 May 2020 in IEEE/ASME Transactions on Mechatronics
We develop two end-effectors for robot-assisted microsurgery with the aim of implementing compact and lightweight devices that can drive hand-operated commercial surgical instruments such as forceps and scissors. To achieve this objective, we mainly consider the type of actuator and the driving mechanism that influence not only the working performance but also the structural features of devices. As a suitable actuator, we employ shape memory alloy actuators because of their operational benefits such as high energy density and configurational simplicity. The two drivers are designed with the geometric models and then fabricated as functional prototypes for performance evaluation. Further, we investigate the practical applicability and usability of the devices based on the robot-assisted microsurgery on animal subjects. In the in-vivo experiment, we perform the epineurium windowing microsurgery. In this surgery, which is performed as a prerequisite of the process for conducting the visualization of peripheral nerve fibers with a confocal laser endo-microscope, we can precisely peel off the outer membrane of the peripheral nerve (approximately 1 mm in diameter) by using a tele-operated surgical robot equipped with the proposed end-effectors. The result of peripheral nerve fiber visualization demonstrates that the proposed devices can be suitably utilized for epineurium windowing microsurgery.
24 January 2020 in IEEE Robotics and Automation Letters
We develop a surgical forceps-driver and a haptic feedback master device that could be applied to a tele-operated microsurgical robotic system for peripheral nerve surgery. Considering that the neurological damage could occur to the peripheral nerve when an excessive force is applied to the nerve tissue, we aim to implement the forceps-driver with precision gripping-force control and the master device capable of providing haptic feedback. For this aim, a high-precision tiny force sensor is fabricated and embedded into the forceps-driver for gripping-force measurement. And, we develop a novel master device handled by surgeonapos;s thumb and forefinger. As a kind of a variable stiffness module, it functions to generate the forceps-drive operation command according to a surgeonapos;s pinching motion and to display haptic feedback by varying the stiffness based on the gripping-force measured from the slave device. Thus, the surgeon can tele-operate the forceps-driver intuitively as well as feel the gripped-object by proprioceptive haptic feedback. In the performance evaluation experiments for the master-slave system, the gripping-force measurement capacity of the forceps-driver and the stiffness variation range of the master device are investigated as about 4 N with a resolution of 0.03 N and about 3.6 N/mm with a resolution of 0.025 N/mm, respectively.
1 April 2014 in International Journal of Control, Automation, and Systems