Acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI) is a frequent complication associated with adverse outcomes and mortality. Various scores have been developed to predict this complication in the coronary setting. However, none have ever been tested in a large TAVI population. This study aimed to evaluate the power of four different scores in predicting AKI after TAVI. Overall, 1535 consecutive TAVI patients from the observational multicentric "Magna Graecia" TAVI registry were included in the analysis. Of the study population, 235 (15.31%) developed AKI early. The Mehran, William Beaumont Hospital, CR4EATME3AD3, and ACEF scores were calculated retrospectively. The patients who developed TAVI-related AKI had significantly higher absolute values of all risk scores than those who did not. The receiver-operating characteristic analysis also showed a significant correlation between these four scores and AKI, but without a significant difference among all of them (p value = 0.176). Nevertheless, based on their area under the curve values (≤0.604 for all), none had adequate diagnostic accuracy in predicting TAVI-related AKI. Importantly, multivariate analysis identified myocardial revascularization close to the TAVI procedure and implantation of self-expanding prostheses, as well as atrial fibrillation, low-osmolar contrast media administration, corrected contrast medium volume, and any transfusion (p value < 0.05 for all) as independent risk factors for AKI. Although high values of current AKI risk scores are significantly associated with the development of this complication, these are not sufficiently accurate. Further studies are needed so that a TAVI-dedicated AKI risk score may be created.
6 December 2022 in Journal of the American Heart Association
Background: Long‐term outcomes of ST‐segment–elevation myocardial infarction in patients with diabetes have been barely investigated. The objective of this analysis from the EXAMINATION‐EXTEND (10‐Years Follow‐Up of the EXAMINATION trial) trial was to compare 10‐year outcomes of patients with ST‐segment–elevation myocardial infarction with and without diabetes. Methods and Results: Of the study population, 258 patients had diabetes and 1240 did not. The primary end point was patient‐oriented composite end point of all‐cause death, any myocardial infarction, or any revascularization. Secondary end points were the individual components of the primary combined end point, cardiac death, target vessel myocardial infarction, target lesion revascularization, and stent thrombosis. All end points were adjusted for potential confounders. At 10 years, patients with diabetes showed a higher incidence of patient‐oriented composite end point compared with those without (46.5% versus 33.0%; adjusted hazard ratio [HR], 1.31 [95% CI, 1.05–1.61]; P =0.016) mainly driven by a higher incidence of any revascularization (24.4% versus 16.6%; adjusted HR, 1.61 [95% CI, 1.19–2.17]; P =0.002). Specifically, patients with diabetes had a higher incidence of any revascularization during the first 5 years of follow‐up (20.2% versus 12.8%; adjusted HR, 1.57 [95% CI, 1.13–2.19]; P =0.007) compared with those without diabetes. No statistically significant differences were found with respect to the other end points. Conclusions: Patients with ST‐segment–elevation myocardial infarction who had diabetes had worse clinical outcome at 10 years compared with those without diabetes, mainly driven by a higher incidence of any revascularizations in the first 5 years. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04462315.
Background: The COVID-19 pandemic increased the complexity of the clinical management and pharmacological treatment of patients presenting with an Acute Coronary Syndrome (ACS). Aim: to explore the incidence and prognostic impact of in-hospital bleeding in patients presenting with ACS before and during the COVID-19 pandemic. Methods: We evaluated in-hospital Thrombolysis In Myocardial Infarction (TIMI) major and minor bleeding among 2851 patients with ACS from 17 Italian centers during the first wave of the COVID-19 pandemic (i.e., March–April 2020) and in the same period in the previous two years. Results: The incidence of in-hospital TIMI major and minor bleeding was similar before and during the COVID-19 pandemic. TIMI major or minor bleeding was associated with a significant threefold increase in all-cause mortality, with a similar prognostic impact before and during the COVID-19 pandemic. Conclusions: the incidence and clinical impact of in-hospital bleeding in ACS patients was similar before and during the COVID-19 pandemic. We confirmed a significant and sizable negative prognostic impact of in-hospital bleeding in ACS patients.
Background: Transcatheter aortic valve replacement (TAVR) is an almost totally cine-fluoroscopic guided procedure. The amount of radiation used during the procedure is strictly related to the fluoroscopy time (FT), that has already been demonstrated to be associated with outcomes and complexity of coronary procedures. The aim of our study is to demonstrate the relationship between FT and the short-term outcomes after TAVR defined by to the Valve Academic Research Consortium (VARC)-2 and -3 consensus documents. Methods: After splitting 1797 consecutive patients into tertiles of FT, the composite endpoint early safety (ES) was adjudicated according to VARC-2 and VARC-3 definitions, whereas the composite endpoints device success (DS) and technical success (TS) according to VARC-3 criteria. Results: The absence of all these outcomes (VARC-2 ES amd VARC-3 TS, DS, and ES) was significantly associated with longer FT: this association was independent from both intraprocedural complications and other intraprocedural factors linked to longer FT, and still persisted after propensity score matching analysis. Notwithstanding, after receiver operating characteristic analysis, FT had adequate diagnostic accuracy in identifying the absence of only VARC-3 TS and VARC-2 ES. Conclusion: Longer FT is related with periprocedural and short-term outcomes after the procedure, especially in those that are more challenging. A FT duration of more than 30 min has an adequate accuracy in identifying VARC-3 technical failure (TS and DS) and absence of VARC-2 ES, selecting patients who are likely to take advantage from more careful in-hospital follow-up.
Objective Transcatheter aortic valve replacement (TAVR) is a cine-fluoroscopic guided procedure. The amount of radiation used during the procedure is strictly related with fluoroscopy time (FT) that has been demonstrated to be associated with outcomes and complexity of procedure in percutaneous coronary interventions. The aim of our study is to demonstrate the relationship between FT and short-term outcomes after TAVR. Methods After splitting 1797 consecutive patients according to tertiles of FT, the composite endpoint early safety (ES) was adjudicated according to Valve Academic Research Consortium (VARC)-2 and -3 consensus documents and the composite endpoints of device success (DS) and technical success (TS) according to VARC-3 criteria. Results The absence of all outcomes (TS, DS, and ES according to VARC-3 and ES according to VARC-2) was significantly associated with higher FT and this association persisted after propensity score matching analysis. Notwithstanding, after receiver operating characteristic analysis, only the FT cut-offs identified for VARC-3 TS and VARC-2 ES had adequate diagnostic accuracy in identifying the absence of these endpoints. Conclusions Longer FT is related with peri-procedural and short-term outcomes after the procedure, especially in those that are more complex. A FT duration of more than 30 minutes has an adequate accuracy in identifying VARC-3 technical failure and absence of VARC-2 ES. What is already known on this topic FT is related with complexity and outcomes in PCI. No data is available about FT and TAVR. What this study adds FT >30 minutes has an adequate accuracy in identifying VARC-3 technical failure and absence of VARC-2 ES. How this study might affect research, practice or policy FT that lasts more than 30 minutes in TAVR is linked independently to short-term adverse outcomes after TAVR. A strict follow-up is needed in this procedural setting as FT is a new independent predictor of adverse outcome after TAVR.
21 February 2022 in JACC: Cardiovascular Interventions