Acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI) is a frequent complication associated with adverse outcomes and mortality. Various scores have been developed to predict this complication in the coronary setting. However, none have ever been tested in a large TAVI population. This study aimed to evaluate the power of four different scores in predicting AKI after TAVI. Overall, 1535 consecutive TAVI patients from the observational multicentric "Magna Graecia" TAVI registry were included in the analysis. Of the study population, 235 (15.31%) developed AKI early. The Mehran, William Beaumont Hospital, CR4EATME3AD3, and ACEF scores were calculated retrospectively. The patients who developed TAVI-related AKI had significantly higher absolute values of all risk scores than those who did not. The receiver-operating characteristic analysis also showed a significant correlation between these four scores and AKI, but without a significant difference among all of them (p value = 0.176). Nevertheless, based on their area under the curve values (≤0.604 for all), none had adequate diagnostic accuracy in predicting TAVI-related AKI. Importantly, multivariate analysis identified myocardial revascularization close to the TAVI procedure and implantation of self-expanding prostheses, as well as atrial fibrillation, low-osmolar contrast media administration, corrected contrast medium volume, and any transfusion (p value < 0.05 for all) as independent risk factors for AKI. Although high values of current AKI risk scores are significantly associated with the development of this complication, these are not sufficiently accurate. Further studies are needed so that a TAVI-dedicated AKI risk score may be created.
30 September 2018 in Catheterization and Cardiovascular Interventions
Background: Surgical mortality risk scores, even if not properly designed and rarely tested in the transcatheter aortic valve implantation (TAVI) setting, still guide the heart team in managing significant aortic stenosis. Methods: After splitting 1763 consecutive patients retrospectively based on their mortality risk thresholds, the composite endpoint early safety (ES) was adjudicated according to Valve Academic Research Consortium (VARC)-2 and -3 consensus documents. Results: ES incidence was higher if VARC-2 rather than VARC-3 defined. Despite only patients showing VARC-2 ES had significantly lower absolute values of all three main risk scores, these last still failed to foresee both VARC-2 and -3 ES in intermediate-risk patients. The receiver operating characteristic analysis also showed a significant correlation, but with poor diagnostic accuracy, among the three scores and only VARC-2 ES; moreover, the absence of VARC-2 ES and low-osmolar contrast media administration were identified as independent predictors of 1-year mortality and absence of VARC-3 ES, respectively. Finally, even a single complication included in the ES definition could significantly affect 1-year mortality. Conclusion: Currently, the most used mortality risk scores do not have adequate diagnostic accuracy in predicting ES after TAVI. The absence of VARC-2, instead of VARC-3, ES is an independent predictor of 1-year mortality.