Nabarun Saha

Dr. Nabarun Saha

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
NSNabarun Saha
Nabarun Saha
Giuseppe BrunettiGiuseppe Brunetti
Giuseppe Brunetti
AKArun Kumar
Arun Kumar
MAMario Nicola Armenise
Mario Nicola Armenise
Caterina CiminelliCaterina Ciminelli
Caterina Ciminelli
The measurement of small changes in the refractive index (RI) leads to a comprehensive analysis of different biochemical substances, paving the way to non-invasive and cost-effective medical diagnosis. In recent times, the liquid biopsy for cancer detection via extracellular vesicles (EV) in the bodily fluid is becoming very popular thanks to less invasiveness and stability. In this context, here we propose a highly sensitive RI sensor based on a compact high-index-coated polymer waveguide Bragg grating with a metal under cladding. Owing to the combined effect of a metal under cladding and a high-index coating, a significant enhancement in the RI sensitivity as well as the dynamic range has been observed. The proposed sensor has been analyzed by combining finite element method (FEM) and coupled-mode theory (CMT) approaches, demonstrating a sensitivity of 408–861 nm/RIU over a broad dynamic range of 1.32–1.44, and a strong evanescent field within a 150 nm proximity to the waveguide surface compliant with EV size. The aforementioned performance makes the proposed device suitable for performing real-time and on-chip diagnoses of cancer in the early stage.

10 July 2023 in IEEE Journal of Photovoltaics
Verified
Journal Article
Open access
NSNabarun Saha
Nabarun Saha
Giuseppe BrunettiGiuseppe Brunetti
Giuseppe Brunetti
MAMario Nicola Armenise
Mario Nicola Armenise
Aldo Di CarloAldo Di Carlo
Aldo Di Carlo
Caterina CiminelliCaterina Ciminelli
Caterina Ciminelli
Perovskite-based solar cells have observed tremendous growth in the last decade aiming at developing renewable energy sources. The enhancement of the power conversion efficiency (PCE), sustainability, and easing of the fabrication are the main driving forces of the ongoing research activity. In this context, graphene is particularly promising since it not only provides better charge collection but also helps to improve the sustainability and low-temperature fabrication of the perovskite cell. Here, a homojunction MaPbI 3 perovskite solar cell with graphene-TiO 2 nano-composite as the electron transport layer (ETL) has been numerically investigated. The effect of doping concentration on the p and n-doped section in the homojunction-MaPbI 3 has been studied, showing that 10 17 and 10 16 cm −3 doping on the p and n section of MaPbI 3 , respectively, provide the best band alignment with the ETL layer. The optimum thickness ratio of two doped sections (p:n) is found to be 60:40 in %. Moreover, the presence of graphene in the TiO 2 layer improves PCE thanks to enhanced fill factor and saturated current density. A combined effect of all these results in a PCE of 22.71% with a 100 nm thick ETL layer having an optimum graphene concentration of around 1%.

10 March 2023 in IEEE Photonics Journal
Verified
Journal Article
Open access
NSNabarun Saha
Nabarun Saha
Giuseppe BrunettiGiuseppe Brunetti
Giuseppe Brunetti
MAMario Nicola Armenise
Mario Nicola Armenise
Caterina CiminelliCaterina Ciminelli
Caterina Ciminelli
Accurate probing, monitoring, and controlling the pH level is critical in different fields. In the last two decades, optical fiber/waveguide-based pH sensors have been widely investigated with the aim of further enhancement of sensitivity and miniaturization. Here, we propose a novel and cost-effective pH sensor based on polymer waveguide Bragg grating, addressing main aspects like sensitivity enhancement, miniaturization, narrow band response, and stable performance. The large evanescent field due to metal under cladding and high index coating combined with excellent penetration depth match with pH-sensitive polymer coating of poly-acrylic acid/poly-allylamine hydrochloride (PAA/PAH) in an aqueous medium, ensures a sensitivity of 10.4 nm/pH for a pH range of 4 to 7, two orders higher than all reported Bragg grating pH sensors to our knowledge. A narrow band (∼1 nm) response has been ensured by low propagation loss of the TE mode. Further, the variations in sensitivity and peak reflectivity are within 3% for a ±10% inaccuracy in various structural parameters, reflecting excellent fabrication tolerances. The proposed sensor is an important development, especially for the perishable food industry in which a high sensitivity in a pH range of 4 to 7 is highly desirable to accurately determine the freshness of foods.

24 February 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KDKrishnendu Dandapat
Krishnendu Dandapat
NSNabarun Saha
Nabarun Saha
RDRanjeet Dwivedi
Ranjeet Dwivedi
STSaurabh Mani Tripathi
Saurabh Mani Tripathi
AKArun Kumar
Arun Kumar
To the best of our knowledge, we are the first to report the existence of two dispersion turning points (DTP) in an optimized planar waveguide long-period grating (LPG) sensor for the lowest order cladding mode. Using numerical simulation, we investigate the potential of the sensor structure for bulk refractive index (RI) and surface sensing, with the goal of predicting its possible application as an integrated photonic biosensor. The proposed sensor exhibits an exceptionally high RI sensitivity ~7500 nm/refractive index unit (RIU) (~10000 nm/RIU) near lower (higher) DTP. The surface sensitivity, which is incredibly high in this form of structure, is found to be 6.5 nm/nm (7 nm/nm) near lower (higher) DTP for the RI relevant for biosensing. Utilizing the sensing characteristics of both the DTP, we propose a dual-slot biosensor by cascading two LPGs having different grating periods. The proposed biosensor shows two independent dual-resonance phenomena and is, therefore, capable of simultaneous detection of dual analytes. Utilizing the proposed dual-slot biosensor, we present simulation results for specific detection of Hepatitis B antigen and DNA hybridization simultaneously. The proposed biosensor will reduce the sensor cost as well as detection time since a single source and detector are required to sense two different analytes at once.

5 February 2018 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
NSNabarun Saha
Nabarun Saha
AKArun Kumar
Arun Kumar
A novel structure with long-period grating in a metal clad ridge waveguide (MCRW) as a highly sensitive ambient refractive index (ARI) sensor is proposed suitable for biosensing applications. We have exploited the coupling between the fundamental mode and a higher order mode via the long period grating written in the photosensitive core of the MCRW. Utilizing quasitransverse electric (TE) modes of the MCRW structure, it is shown that ARI sensitivity of ~100 μm/refractive index unit (RIU) can be achieved by using dual resonance near dispersion turn around point. This ultrahigh sensitivity can be attributed to the metal under-cladding which enhances the evanescent field in the ambient medium more prominently for the higher order modes as compared to the fundamental mode. It is shown that device compactness is also increased significantly due to the metal undercladding. Further, the propagation lengths of quasi-TE modes in the proposed structure are about 35 to 185 times higher than that of quasi-transverse magnetic modes due to which, no in-line polarizer is required in the proposed device.

7 August 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
NSNabarun Saha
Nabarun Saha
AKArun Kumar
Arun Kumar
In this paper we are proposing a novel and highly sensitive refractive index sensor based on cladding mode transition in a high index coated ridge waveguide with long period grating written in its core, operating near the dispersion turning point. We have theoretically examined the phenomena of cladding mode transition in the ridge waveguide and optimized the thickness of the high index layer to obtain high refractive index sensitivity. Considering the optimized thickness and the coupling between the core mode and a suitable cladding mode, it is shown that (a) the refractive index sensitivity more than 100 μm/RIU at bio-sensing refractive index 1.33 and (b) a surface sensitivity as high as 36 nm/nm for a thin bio-layer with aqueous solution as the ambient medium can be obtained near the dispersion turning point. In addition, the refractive index sensitivity is found to vary only by 3 μm/RIU for a ±100 nm variation in the width of the ridge waveguide. The proposed device should be a promising development in the field of optical biosensors.