Both density and surface tension were systematically investigated over a wide temperature and compositional range for the liquid Al–V alloy system. The thermophysical properties were measured in an electromagnetic levitation device. A linear decrease in surface tension and density with increasing temperature was observed for every alloy composition investigated. Additionally, a decrease in density and surface tension was observed for increasing aluminum content among the different probed samples. This decrease is, a strong deviation from an ideal mixing behavior which was experienced for both properties. Different models, including variants of the well-established Butler model, were employed to better describe the compositional dependence of density and surface tension in the liquid Al–V system. The advantages and disadvantages were discussed for each model describing the measured thermophysical property data. Strong similarities were observed when comparing the mixing behavior and segregation effects of the investigated Al–V system with already established works for the liquid Al–Ti system. The results suggest that both vanadium and titanium show similar mixing behavior when alloyed with aluminum.
The thermophysical properties of molten Fe–Cu alloys, including density, surface tension, and viscosity, were measured using the electrostatic levitation furnace aboard the International Space Station (ISS-ELF) under microgravity conditions, which provided an environment that facilitated accurate measurements. The densities of the molten Fe–25at%Cu and Fe–50at%Cu alloys decreased linearly with increasing temperature, and higher copper compositions resulted in increased density. The surface tension of the molten alloys exhibited a unique up-convex temperature dependence curve that initially increased and then decreased as the temperature increased. Viscosity measurements indicated that the viscosity of the molten Fe–Cu alloys decreased with increasing temperature, following a quadratic curve, and that an increase in the copper composition resulted in lower viscosity.
1 January 2023 in High Temperature Materials and Processes
Round-robin measurement of surface tension of high-temperature liquid platinum was conducted free of any contamination from the supporting materials and oxygen adsorption, using an electrostatic levitator (ESL), two electromagnetic levitator (EML), and an aerodynamic levitator (ADL). The measured temperature dependences of the surface tension using ESL and two EMLs were in good agreement and were expressed as σ = 1,798 ± 74.3 − ( 0.12 ± 0.0445 ) × ( T − 2,041 ) \sigma =\mathrm{1,798}\pm 74.3-(0.12\pm 0.0445)\times (T-\mathrm{2,041}) [10 –3 N·m –1 ] (1,900–2,600 K). However, the surface tension values measured with ADL were slightly lower than those exceeding the uncertainty of the measurement plots at high temperatures.
To accurately measure the surface tension of liquid titanium free of contamination from chemical reaction with the supporting materials and dissolution of atmospheric oxygen, the measurement was performed by using electromagnetic levitation (EML) and electrostatic levitation (ESL) in consideration of the influence of oxygen partial pressure of the measurement atmosphere, . When liquid titanium was maintained at 2000 K under Ar–He gas with of 10 Pa flowing at 2 L·min−1 using EML, the surface tension decreased with time due to the dissolution of atmospheric oxygen into the sample. When the of the gas was decreased to 10−2 Pa, the oxygen content and the surface tension were confirmed to not vary, even after 120 min. Even though further decreased to 10−11 Pa under Ar–He–H2 gas, the surface tension slightly increased with time due to gas phase equilibrium between H2 and H2O that allowed for a continuous dissolution of atmospheric oxygen into the liquid titanium. The surface tension of liquid titanium measured by ESL, which prevents contamination of the sample from supporting materials and the high 10−5 Pa vacuum inhibits the dissolution of oxygen, showed almost the same value as that measured under Ar–He gas at of 10−2 Pa by EML. From the measurement results of EML and ESL, the surface tension of the 99.98 mass % pure liquid titanium, free from any contaminations from chemical reactions, with the supporting material and dissolved oxygen was expressed as (10−3 N·m−1).
The densities of CaO–SiO2–FeO melts were measured under microgravity conditions using the Electrostatic Levitation Furnace aboard the International Space Station (ISS-ELF). The nominal FeO contents were 20, 60, and 80 mass% (CS20F, CS60F, and CS80F, respectively), with CaO and SiO2 comprising the balance in a 1:1 mass ratio. Density was calculated from the sample mass and the droplet volume determined using shadow images recorded during cooling. For all compositions, the density decreased approximately linearly with increasing temperature. At a given temperature, the density increased with increasing FeO-equivalent content. The maximum relative expanded uncertainty in the density was 3.46 %, with a coverage factor of k = 2. After the experiments, the recovered samples were analyzed using scanning electron microscopy–energy-dispersive X-ray spectroscopy. Molar volumes were calculated from the measured densities using compositions derived from the measured Ca, Si, and Fe contents, and they were compared with literature data and an additive reference at approximately 1400 °C. The molar volume decreased from CS20F to CS60F and changed only slightly between CS60F and CS80F. The molar volumes of CS20F and CS60F were close to the additive reference, whereas that of CS80F showed a clear positive deviation.