Qi Lu

Dr. Qi Lu

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
QLQi Lu
Qi Lu
BRBeibei Ren
Beibei Ren
SPSiva Parameswaran
Siva Parameswaran
This paper presents an uncertainty and disturbance estimator (UDE)-based global trajectory tracking control strategy for a quadrotor. The main contribution of this paper is the fusion of the UDE technique with the unit quaternion to achieve the robust global full degrees of freedom trajectory tracking control with experimental demonstrations. The novelty of this paper lies in the development of the UDE-based global tracking technique to the overall system (attitude and position) with a quaternion-based nonlinear reference model. The UDE-based attitude and position controllers are derived from the unit quaternion-based quadrotor dynamics with a cascade control structure to deal with underactuation, model uncertainties and external disturbances. The attitude controllers which are developed with the backstepping techniques avoid the rotation matrix calculation and the unwinding problem. The position controllers are derived using the thrust-vectoring approach. A nonlinear unit quaternion-based reference model is developed to achieve the time-scale separation for the cascade control loops. The stability analysis of the closed-loop system is conducted with Lyapunov method. Extensive flight experiments are conducted to demonstrate the global singularity-free tracking property and the superior robustness of the proposed controller.

12 January 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
YWYafeng Wang
Yafeng Wang
QLQi Lu
Qi Lu
BRBeibei Ren
Beibei Ren
The camera-equipped quadrotor is a preferable choice for wind turbine blade (WTB) crack inspection applications with the benefits of high portability and low cost. Unfortunately, the high speed of the quadrotor might cause image motion blur which leads to a crack detection failure. Recent works cope with this by adopting the advanced camera systems or image deblurring techniques, which, however, usually require additional hardware or extra computational load. In this paper, the crack detection failure problem caused by image motion blur is handled by means of quadrotor motion control. First, the desired speed range that can avoid the detection failure caused by the image motion blur is experimentally obtained. Then, a speed regulation controller is developed to regulate the quadrotor flying speed within the obtained range. Experimental studies for crack inspection of a WTB using a camera-equipped quadrotor under wind condition are carried out to validate the effectiveness of the proposed strategy. Compared to the traditional approach without image motion blur avoidance, with the same inspection assignment and wind condition, the proposed method can obtain better quality images with 4.08 higher peak signal-to-noise ratio (PSNR) and 0.1 higher structural similarity index (SSIM) on average, where PSNR and SSIM are two typical image quality assessment metrics. As a result, the crack detection failure problem is avoided and a successful WTB crack inspection is achieved.

29 June 2023 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
Verified
Journal Article
Closed access
XLXiangyun Li
Xiangyun Li
QLQi Lu
Qi Lu
JCJiali Chen
Jiali Chen
NJNing Jiang
Ning Jiang
KLKang Li
Kang Li
For the safe and smooth robot-assisted healthcare task execution, real-time motion tracking controls and compliant physical human–robot interactions are concurrently important control objectives. In this work, the uncertainty and disturbance estimator (UDE)-based robust region tracking controller for a robot manipulator is developed. The regional feedback error is derived from the potential function to drive the robot manipulator end-effector converging into the target region, where the safe and compliant physical human–robot interaction can be achieved. Utilizing the back-stepping control approach, the regional feedback error is seamlessly integrated into the UDE-based control framework, where the UDE is employed to estimate and compensate model uncertainties such that only the minimum model information is needed for implementation. The Lyapunov method is used to analyze the stability of the closed-loop control system. Extensive experimental studies including trajectory tracking, human–robot interaction and benchmark comparison are carried out for controller effectiveness validation.

20 September 2022 in Journal of Mechanical Design
Verified
Journal Article
Closed access
PDF file
XLXiangyun Li
Xiangyun Li
HLHao Lv
Hao Lv
PZPing Zhao
Ping Zhao
QLQi Lu
Qi Lu

5 June 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
JXJiakai Xu
Jiakai Xu
HZHaopeng Zhou
Haopeng Zhou
QLQi Lu
Qi Lu
XLXiangyun Li
Xiangyun Li
KLKang Li
Kang Li
Medical ultrasound is an essential noninvasive diagnostic tool across various disciplines, yet its dependence on skilled practitioners presents significant challenges to achieving efficient autonomous imaging. This article presents an autonomous robotic ultrasound scanning method enhanced with multimodal sensing and distance probSparse self-attention (DPSA). By integrating ultrasound images, dual-view cameras, tactile feedback, and robotic action sequences, the system achieves comprehensive environmental perception. The 6-D pose decision-making task for the robot is formulated as a deep reinforcement learning (DRL) problem, and a hybrid reward function is designed to conform to professional sonographers. The proposed DPSA mechanism is designed to capture critical information from the current multimodal sensory data by allocating greater attention to important time steps. In addition, this work employs the discrete soft actor–critic (DSAC) algorithm, prioritized experience replay (PER), and a pretrained ResNet-18 model, significantly reducing training time. Evaluation in real-world environments using soft, movable, and unmarked kidney phantoms demonstrates that our approach outperforms existing baseline models in terms of scanning success rate, accuracy, and training efficiency, while maintaining robust stability under interference conditions.

1 April 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XLXiangyun Li
Xiangyun Li
QLQi Lu
Qi Lu
ZHZhiheng Huang
Zhiheng Huang
KLKang Li
Kang Li
The six degrees-of-freedom (DoFs) nonsingular pose tracking is the prerequisite for the smooth task executions in many robot-assisted medical scenarios, such as laparoscopic surgery and sonography. This work develops a robust position/orientation tracking controller for a robot manipulator based on unit dual quaternion algebra. First, the dual quaternion-based robot manipulator dynamics are derived to accomplish the computationally minimalistic nonsingular end-effector motion representation. Then, an uncertainty and disturbance estimator-based controller is developed to estimate and compensate the system lumped uncertainty, which includes parameter uncertainty, external force/torque disturbance, and motor nonlinearity. The remote center of motion (RCM) constraints are formulated into the dual quaternion space to achieve the singularity free tool manipulation. The boundedness of the pose tracking error is analyzed via the Lyapunov function. Experiments of RCM operation with a seven DoFs Franka Emika robot manipulator are conducted for the performance validation, where the position root mean squared errors (RMSEs) are less than 0.002 m and the orientation RMSEs are less than 0.15°.