This paper presents an uncertainty and disturbance estimator (UDE)-based global trajectory tracking control strategy for a quadrotor. The main contribution of this paper is the fusion of the UDE technique with the unit quaternion to achieve the robust global full degrees of freedom trajectory tracking control with experimental demonstrations. The novelty of this paper lies in the development of the UDE-based global tracking technique to the overall system (attitude and position) with a quaternion-based nonlinear reference model. The UDE-based attitude and position controllers are derived from the unit quaternion-based quadrotor dynamics with a cascade control structure to deal with underactuation, model uncertainties and external disturbances. The attitude controllers which are developed with the backstepping techniques avoid the rotation matrix calculation and the unwinding problem. The position controllers are derived using the thrust-vectoring approach. A nonlinear unit quaternion-based reference model is developed to achieve the time-scale separation for the cascade control loops. The stability analysis of the closed-loop system is conducted with Lyapunov method. Extensive flight experiments are conducted to demonstrate the global singularity-free tracking property and the superior robustness of the proposed controller.
17 August 2017 in IEEE Transactions on Industrial Electronics
In this paper, a new control structure is proposed for grid-tied photovoltaic (PV) systems where the dc bus voltage is regulated by the dc/dc converter controller, whereas the maximum power point tracking (MPPT) function and the power flow control are embedded into the dc/ac converter controller. A PV voltage-regulation is designed to build the linkage between MPPT function and power flow control. In this way, the dc/dc converter controller and the dc/ac converter controller are decoupled, which naturally provides the dc bus voltage protection. In particular, an uncertainty and disturbance estimator (UDE)-based current-mode controller (CMC) is proposed for accurate voltage regulation of the dc/dc converter. And a bounded-voltage power flow control strategy is proposed for the dc/ac converter to improve the existing UDE-based robust power flow control for ac voltage protection. The effectiveness of the proposed method is experimentally validated in a lab-environment grid-tied PV system platform with the fault ride-through capabilities. In addition, simulation studies are also provided to demonstrate the need of the PV voltage-regulation between MPPT and power flow control, and the advantages of the bounded-voltage design in the power flow control.
20 November 2017 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
A fundamental requirement in robot control is the capability to improve the robot-environment interaction performance. Motivated by the fact that humans are able to adapt limb impedance to stably interact with various environments with skillful dexterity, this paper investigates the variable impedance control for robots, subject to uncertainties from plant model or environment. The proposed variable impedance control assists the robot to perform given interaction tasks with its unknown environment and improves the overall robot-environment system performance. The stiffness, damping, and inertia can be changed during interaction tasks, which results in configuration-dependent impedance dynamics. The uncertainty and disturbance estimator (UDE) is used to approximate the plant model with only partial information known. The prominent feature of the UDE-based control is that only the bandwidth information of the unknown plant model is needed for the control design. A stability condition for selecting the stiffness, damping, and inertia in the impedance model is provided to guarantee the stability of the control system. Extensive simulation studies are carried out to illustrate the effectiveness of the proposed method.
29 June 2016 in IEEE Transactions on Industrial Electronics
In this paper, an uncertainty and disturbance estimator (UDE)-based robust power flow control is developed for grid-connected inverters to achieve accurate power delivery to the grid. The model of power delivering with both frequency dynamics and voltage dynamics is derived at first. The UDE method is introduced into the controller design to deal with model uncertainties (e.g., output impedance and power angle), coupling effects, and external disturbances (e.g., the fluctuation of the dc-link voltage, the variation of output impedance/line impedance, and the variations of both frequency and amplitude in the grid voltage). Also, this controller does not need a voltage regulator or a current regulator and is easy for the implementation and parameter tuning through the design of the desired tracking error dynamics and the UDE filters. Experimental results are provided to show the effectiveness of the proposed method for different disturbance rejection scenarios, the low-voltage fault-ride through capability, and the weak grid operation capability. The good robustness of the UDE-based control is also demonstrated through the comparison with two other controllers: the proportional-integral controller and the active disturbance rejection controller.
29 January 2020 in IEEE Transactions on Industrial Electronics
The uncertainty and disturbance estimator (UDE)-based controller has emerged as an effective robust control method to handle systems with uncertainties and disturbances. However, similar to other controllers including an integral action, the UDE-based controller faces the integral windup issue when the system has input constraints. In this paper, a bounded UDE-based controller is proposed to deal with systems subject to uncertainties, disturbances and input constraint. An additional time-varying variable is introduced into the design of the error dynamics to naturally avoid integral windup. The boundedness design guarantees that both the final controller output and the additional time-varying variable dynamically move on an ellipse so that the controller output always satisfies the input constraint. The proposed bounded UDE-based controller inherits the robustness of the conventional UDE-based control method, and has a clear structure, with guidelines provided for parameter selections. Both theoretical analysis and experimental results are provided to validate the proposed design.
9 December 2020 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
This article presents a control strategy to improve the energy efficiency of a quadrotor for field inspections. A power consumption analytical model for a quadrotor is constructed, which indicates that the power consumption of a quadrotor is correlated with the roll and pitch angles. Based on that, a cascaded bounded control framework is developed to regulate the roll and pitch angles within the predefined energy-efficient ranges, while a successful inspection trajectory tracking can be achieved simultaneously. Experimental studies are carried out to prove the effectiveness of the proposed method through a mock-up scenario of wind farm inspection. Compared to the conventional cascaded control framework, the proposed energy saving control strategy is capable of saving 5% energy for the same inspection assignment under wind disturbance.