Michael L. McIntyre

Dr. Michael L. McIntyre

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2021 in IEEE Access
Verified
Journal Article
Open access
HGHuangjie Gong
Huangjie Gong
VRVandana Rallabandi
Vandana Rallabandi
MMMichael L. McIntyre
Michael L. McIntyre
Eklas HossainEklas Hossain
Eklas Hossain
Dan M. IonelDan M. Ionel
Dan M. Ionel
Domestic load profiles in the residential sectors are being modified with the adoption of smart home management systems and solar generation. In addition, houses with rooftop PV behave like local generators, contributing to the growth of the penetration of PV energy. Hence, the demand for power is declining day by day. However, the increasing PV penetration causes technical challenges for the power system, such as the “duck curve”. This can be addressed through home energy management (HEM) techniques including peak shaving, load shifting with smart home devices. In this regard, electric water heaters (EWH), with high thermal mass and being ubiquitous, are attractive and low-cost energy storage systems. In this article, a case study for one of the largest rural field smart energy technology demonstrators involving business, industries, and more than 5,000 residences, located in Glasgow, KY, US, is presented. Furthermore, a HEM system, which aims to minimize the total energy usage and peak demand by regulating the heating, ventilation, and air-conditioning (HVAC) systems, water heaters, and batteries, thereby benefiting both the utility and the consumer is proposed. This work also demonstrates the ability of EWH to provide ancillary services while maintaining customer comfort. The minimum participation rates for EWH and batteries are calculated and compared with respect to different peak reduction targets. Long term load prediction by considering different fractions of smart homes for the utility is also provided.

21 June 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JLJoseph Latham
Joseph Latham
MMMichael L. McIntyre
Michael L. McIntyre
MMMohammad Mohebbi
Mohammad Mohebbi
Linear compressors are becoming more widely utilized in refrigeration for their high efficiency in comparison with traditional rotary devices. The nature of the free piston in a linear compressor requires additional control which necessitates knowledge of the mechanical dynamics of the system. Sensorless control of the system is preferred for cost effectiveness. To this end, a pair of nonlinear observers have been developed to observe signals within the system dynamics and reduce the need for costly sensors. The first utilizes a current and voltage measurements to arrive at an observed velocity. The second utilizes a velocity measurement to arrive at observations of piston acceleration as well as a lumped uncertainty term in the mechanical dynamics. A stability analysis is presented to prove boundedness and convergence for these nonlinear observers with experimental results providing further validation. As these observers rely on accurate knowledge of the model parameters, to this end, an estimator has been designed to estimate the electrical parameters of the system. Experimental results validate this method as well.

9 June 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
MAMoath Alqatamin
Moath Alqatamin
JLJoseph Latham
Joseph Latham
ZSZachary T. Smith
Zachary T. Smith
BGBrandon Grainger
Brandon Grainger
MMMichael L. McIntyre
Michael L. McIntyre
Three-phase inverters for grid-connected applications typically require some form of grid voltage phase detection in order to properly synchronize to the grid and control real and reactive power. This phase detection is usually based upon some type of grid voltage sensing. However, in the present work a method is proposed whereby the phase angle of the grid can be accurately identified solely via the grid current feedback. In the proposed current control scheme, the only measurement is the output inverter current and no phase locked loop (PLL) exists within the scheme. This phase observer is incorporated into a current controller which can manage the injected power to the grid. The design of this combined observer/controller system is motivated and validated via a Lyapunov stability analysis. The performance of the proposed control scheme has been compared with the conventional PI PLL-based control scheme which needs both a grid voltage and current sensor. Experimental results utilizing a Controller+ Hardware-in-the-Loop test bed have been presented in order to validate the proposed observer/controller scheme under normal operation, weak grid, distorted grid and faulty grid conditions. To summarize, this scheme archives current control for a grid connected inverter using only current feedback. In comparison, traditional methods require voltage and current feedback along with a PLL to synchronize with the grid creating a cascaded closed loop control system.

31 December 2013 in Energy Systems
Verified
Journal Article
Closed access
PDF file
NJNicholas Jewell
Nicholas Jewell
LBLihui Bai
Lihui Bai
JNJohn Naber
John Naber
MMMichael L. McIntyre
Michael L. McIntyre

2 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
MAMoath Alqatamin
Moath Alqatamin
MMMichael L. McIntyre
Michael L. McIntyre
Three-phase inverters for photovoltaic grid-connected applications typically require some form of grid voltage phase-angle detection in order to properly synchronize to the grid and control real and reactive power generation. Typically, a phase-locked loop scheme is used to determine this real-time phase angle information. However, in the present work, a novel method is proposed whereby the phase angle of the grid can be accurately identified solely via the grid current feedback. This phase-angle observer is incorporated into a current controller which can manage the real and reactive power of the grid-connected PV inverter system. Moreover, the maximum power point of the photovoltaic arrays is achieved without using a DC–DC converter. The proposed method achieves the grid current and DC-link voltage control objectives without the knowledge of the grid information and without the need for a cascaded control scheme. The design of this combined observer/controller scheme is motivated and validated via a Lyapunov stability analysis. The experimental setup is prototyped utilizing a real-time Typhoon HIL 603 and National Instrument cRIO embedded controller in order to validate the proposed observer/controller scheme under different operation scenarios such as irradiation changes, frequency changes, reactive power injection, and operation with a distorted grid. The results show that the DC-link voltage and the active and reactive powers are well regulated from the proposed control scheme without the measurement of the grid phase and frequency.

1 February 2017
Verified
Conference Paper
Closed access
MMMohammad Mohebbi
Mohammad Mohebbi
MMMichael L. McIntyre
Michael L. McIntyre
JLJoseph Latham
Joseph Latham
PRPablo Rivera
Pablo Rivera
In this paper, a nonlinear backstepping controller is proposed for the control of a 3-phase 3-level diode clamped inverter with an output LC filter under different loads including balanced, unbalanced, linear and nonlinear loads. Also, the seamless transition of the inverter from standalone to grid-tie is investigated while the inverter is under the control of the proposed scheme. Lyapunov stability analysis and simulation results validate the effectiveness of the proposed control solution in terms of tracking objective and in meeting the Total Harmonic Distortion (THD) requirements of IEEE 519 and EN 50160 standards for US and European power systems, respectively.