Claire Liu

Dr. Claire Liu

Chan Zuckerberg Biohub Chicago, Chicago, Illinois, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2020 in Nature Medicine
Verified
Journal Article
Open access
PDF file
HCHa Uk Chung
Ha Uk Chung
ARAlina Y. Rwei
Alina Y. Rwei
AHAurélie Hourlier-Fargette
Aurélie Hourlier-Fargette
SXShuai Xu
Shuai Xu
KLKunHyuck Lee
KunHyuck Lee
John A. RogersJohn A. Rogers
John A. Rogers
Standard clinical care in neonatal and pediatric intensive-care units (NICUs and PICUs, respectively) involves continuous monitoring of vital signs with hard-wired devices that adhere to the skin and, in certain instances, can involve catheter-based pressure sensors inserted into the arteries. These systems entail risks of causing iatrogenic skin injuries, complicating clinical care and impeding skin-to-skin contact between parent and child. Here we present a wireless, non-invasive technology that not only offers measurement equivalency to existing clinical standards for heart rate, respiration rate, temperature and blood oxygenation, but also provides a range of important additional features, as supported by data from pilot clinical studies in both the NICU and PICU. These new modalities include tracking movements and body orientation, quantifying the physiological benefits of skin-to-skin care, capturing acoustic signatures of cardiac activity, recording vocal biomarkers associated with tonality and temporal characteristics of crying and monitoring a reliable surrogate for systolic blood pressure. These platforms have the potential to substantially enhance the quality of neonatal and pediatric critical care.

25 November 2019 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
KLKunHyuck Lee
KunHyuck Lee
XNXiaoyue Ni
Xiaoyue Ni
JLJong Yoon Lee
Jong Yoon Lee
HAHany Arafa
Hany Arafa
DPDavid J. Pe
David J. Pe
John A. RogersJohn A. Rogers
John A. Rogers

25 November 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
YCYeon Sik Choi
Yeon Sik Choi
Yuan-Yu HsuehYuan-Yu Hsueh
Yuan-Yu Hsueh
JKJahyun Koo
Jahyun Koo
QYQuansan Yang
Quansan Yang
RARaudel Avila
Raudel Avila
John A. RogersJohn A. Rogers
John A. Rogers
Bioresorbable electronic stimulators are of rapidly growing interest as unusual therapeutic platforms, i.e., bioelectronic medicines, for treating disease states, accelerating wound healing processes and eliminating infections. Here, we present advanced materials that support operation in these systems over clinically relevant timeframes, ultimately bioresorbing harmlessly to benign products without residues, to eliminate the need for surgical extraction. Our findings overcome key challenges of bioresorbable electronic devices by realizing lifetimes that match clinical needs. The devices exploit a bioresorbable dynamic covalent polymer that facilitates tight bonding to itself and other surfaces, as a soft, elastic substrate and encapsulation coating for wireless electronic components. We describe the underlying features and chemical design considerations for this polymer, and the biocompatibility of its constituent materials. In devices with optimized, wireless designs, these polymers enable stable, long-lived operation as distal stimulators in a rat model of peripheral nerve injuries, thereby demonstrating the potential of programmable long-term electrical stimulation for maintaining muscle receptivity and enhancing functional recovery.

26 May 2022 in Science
Verified
Journal Article
Closed access
YCYeon Sik Choi
Yeon Sik Choi
HJHyoyoung Jeong
Hyoyoung Jeong
RYRose T. Yin
Rose T. Yin
RARaudel Avila
Raudel Avila
APAnna Pfenniger
Anna Pfenniger
JRJohn A. Rogers
John A. Rogers
Temporary postoperative cardiac pacing requires devices with percutaneous leads and external wired power and control systems. This hardware introduces risks for infection, limitations on patient mobility, and requirements for surgical extraction procedures. Bioresorbable pacemakers mitigate some of these disadvantages, but they demand pairing with external, wired systems and secondary mechanisms for control. We present a transient closed-loop system that combines a time-synchronized, wireless network of skin-integrated devices with an advanced bioresorbable pacemaker to control cardiac rhythms, track cardiopulmonary status, provide multihaptic feedback, and enable transient operation with minimal patient burden. The result provides a range of autonomous, rate-adaptive cardiac pacing capabilities, as demonstrated in rat, canine, and human heart studies. This work establishes an engineering framework for closed-loop temporary electrotherapy using wirelessly linked, body-integrated bioelectronic devices.

16 December 2020 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
JKJean Won Kwak
Jean Won Kwak
Mengdi HanMengdi Han
Mengdi Han
Zhaoqian XieZhaoqian Xie
Zhaoqian Xie
HCHa Uk Chung
Ha Uk Chung
JLJong Yoon Lee
Jong Yoon Lee
JRJohn A. Rogers
John A. Rogers
Wireless, soft sensors continuously monitor pressure and temperature at the interface between a residual limb and a prosthesis.

1 July 2022 in Science
Verified
Journal Article
Closed access
JRJonathan T. Reeder
Jonathan T. Reeder
Zhaoqian XieZhaoqian Xie
Zhaoqian Xie
QYQuansan Yang
Quansan Yang
MSMin Ho Seo
Min Ho Seo
YYYing Yan
Ying Yan
JRJohn A. Rogers
John A. Rogers
Implantable devices capable of targeted and reversible blocking of peripheral nerve activity may provide alternatives to opioids for treating pain. Local cooling represents an attractive means for on-demand elimination of pain signals, but traditional technologies are limited by rigid, bulky form factors; imprecise cooling; and requirements for extraction surgeries. Here, we introduce soft, bioresorbable, microfluidic devices that enable delivery of focused, minimally invasive cooling power at arbitrary depths in living tissues with real-time temperature feedback control. Construction with water-soluble, biocompatible materials leads to dissolution and bioresorption as a mechanism to eliminate unnecessary device load and risk to the patient without additional surgeries. Multiweek in vivo trials demonstrate the ability to rapidly and precisely cool peripheral nerves to provide local, on-demand analgesia in rat models for neuropathic pain.