Paweł Łukasz Knihnicki

Dr. Paweł Łukasz Knihnicki


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Talanta
Verified
Journal Article
Closed access
JKJolanta Kochana
Jolanta Kochana
KWK. Wapiennik
K. Wapiennik
JKJ. Kozak
J. Kozak
PKPaweł Łukasz Knihnicki
Paweł Łukasz Knihnicki
APA. Pollap
A. Pollap
PKP. Kościelniak
P. Kościelniak

1 September 2015 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
KPKarolina Persona
Karolina Persona
KMKatarzyna Madej
Katarzyna Madej
PKPaweł Łukasz Knihnicki
Paweł Łukasz Knihnicki
Wojciech PiekoszewskiWojciech Piekoszewski
Wojciech Piekoszewski

21 May 2016 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
JKJolanta Kochana
Jolanta Kochana
KWKarolina Wapiennik
Karolina Wapiennik
PKPaweł Łukasz Knihnicki
Paweł Łukasz Knihnicki
APAleksandra Pollap
Aleksandra Pollap
PJPaula Janus
Paula Janus
Piotr KuśtrowskiPiotr Kuśtrowski
Piotr Kuśtrowski
A voltammetric biosensor based on tyrosinase (TYR) was developed for determination of tyramine. Carbon material (multi-walled carbon nanotubes or mesoporous carbon CMK-3-type), polycationic polymer—i.e., poly(diallyldimethylammonium chloride) (PDDA), and Nafion were incorporated into titania dioxide sol (TiO2) to create an immobilization matrix. The features of the formed matrix were studied by scanning electron microscopy (SEM) and cyclic voltammetry (CV). The analytical performance of the developed biosensor was evaluated with respect to linear range, sensitivity, limit of detection, long-term stability, repeatability, and reproducibility. The biosensor exhibited electrocatalytic activity toward tyramine oxidation within a linear range from 6 to 130 μM, high sensitivity of 486 μA mM−1 cm−2, and limit of detection of 1.5 μM. The apparent Michaelis–Menten constant was calculated to be 66.0 μM indicating a high biological affinity of the developed biosensor for tyramine. Furthermore, its usefulness in determination of tyramine in food product samples was also verified. Different food samples were analyzed to determine tyramine using biosensor based on tyrosinase

1 April 2014 in Journal of Chromatography A
Verified
Journal Article
Closed access
Michal WozniakiewiczMichal Wozniakiewicz
Michal Wozniakiewicz
RWRenata Wietecha-Posluszny
Renata Wietecha-Posluszny
AMAgnieszka Moos
Agnieszka Moos
MWMarcin Wieczorek
Marcin Wieczorek
PKPaweł Łukasz Knihnicki
Paweł Łukasz Knihnicki
PKPaweł Kościelniak
Paweł Kościelniak

25 July 2018 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
APAleksandra Pollap
Aleksandra Pollap
PKPaweł Łukasz Knihnicki
Paweł Łukasz Knihnicki
Piotr KuśtrowskiPiotr Kuśtrowski
Piotr Kuśtrowski
JKJoanna Kozak
Joanna Kozak
MGMonika Gołda‐Cępa
Monika Gołda‐Cępa
JKJolanta Kochana
Jolanta Kochana

19 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
PKPaweł Łukasz Knihnicki
Paweł Łukasz Knihnicki
ASAleksandra Skrzypek
Aleksandra Skrzypek
MJMałgorzata Jakubowska
Małgorzata Jakubowska
RPRadosław Porada
Radosław Porada
ARAnna Rokicinska
Anna Rokicinska
JKJolanta Kochana
Jolanta Kochana
A novel voltammetric method for the sensitive and selective determination of cadmium and lead ions using screen-printed carbon electrodes (SPCEs) modified with carbon-deposited natural halloysite (C_Hal) and multi-walled carbon nanotubes (MWCNTs) was developed. The electrochemical properties of the proposed sensor were investigated by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), while the morphology and structure were established by scanning electron microscopy (SEM) and X-ray powder diffraction (XRD). A two-factorial central composite design (CCD) was employed to select the composition of the nanocomposite modifying the electrode surface. The optimal measuring parameters of differential pulse anodic stripping voltammetry (DPASV) used for quantitative analysis were established with the Nelder–Mead simplex method. In the analytical investigation of Cd(II) and Pb(II) ions by DPASV, the MWCNTs/C_Hal/Nafion/SPCE exhibited a linear response in the concentration range of 0.1–10.0 µmol L−1 (for both ions) with a detection limit of 0.0051 and 0.0106 µmol L−1 for Pb(II) and Cd(II), respectively. The proposed sensor was successfully applied for the determination of metal ions in different natural water and honey samples with recovery values of 96.4–101.6%.