Background: Third-generation transcatheter heart valves (THVs) are designed to improve outcomes. Data on the new intra-annular self-expanding NAVITOR are scarce. Aims: The aim of this analysis was to compare outcomes between the PORTICO and the NAVITOR systems. Methods: Data from 782 patients with severe native aortic stenosis treated with PORTICO (n = 645) or NAVITOR (n = 137) from 05/2012 to 09/2022 were evaluated. The clinical and hemodynamic outcomes of 276 patients (PORTICO, n = 139; NAVITOR, n = 137) were evaluated according to VARC-3 recommendations. Results: Rates of postprocedural more-than-mild paravalvular leakage (PVL) were significantly lower for NAVITOR than for PORTICO (7.2% vs. 1.5%, p = 0.041). In addition, severe bleeding rates (27.3% vs. 13.1%, p = 0.005) and major vascular complications (5.8% vs. 0.7%, p = 0.036) were lower in the NAVITOR group. The mean gradients (7 vs. 8 mmHg, p = 0.121) and calculated aortic valve areas (1.90 cm2 vs. 1.99 cm2, p = 0.235) were comparable. Rates of PPI were similarly high in both groups (15.3 vs. 21.6, p = 0.299). Conclusions: The NAVITOR demonstrated favorable in-hospital procedural outcome data, with lower rates of relevant PVL, major vascular complications, and severe bleeding than its predecessor the PORTICO and preserved favorable hemodynamic outcomes.
1 January 1993 in Antisense Research and Development
It is important to remember that while a new class of therapeutic agents like oligonucleotides may introduce novel concerns, the basic regulatory issues regarding the chemistry, manufacturing, and controls of drug substances and drug products must be addressed. This article focuses on information that should be included in an Investigational New Drug Application (IND), a request to use an investigational drug in clinical studies. The regulatory challenge presented with oligonucleotide therapeutics is to prove the identity of the oligonucleotide, and demonstrate its quality, purity, and strength/potency using both those characteristics that are the same as all other drugs, as well as those that are unique. Most of the discussion will concern issues that are unique to oligonucleotides, or those topics that deserve more detailed attention than would be needed for more typical small molecule drugs. Regulatory issues will need to be evaluated so that safety concerns are addressed while not imposing undue burden on the sponsors of investigational drugs.
20 November 2024 in JACC: Cardiovascular Interventions
Mid-term comparative data for the self-expanding ACURATE neo2 transcatheter heart valve and the balloon-expandable SAPIEN 3 Ultra are lacking. The aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement of these 2 valves. A total of 2,106 patients from 3 centers (neo2, n = 1,166; Ultra, n = 940) undergoing transfemoral transcatheter aortic valve replacement were analyzed retrospectively. The primary endpoint was the composite of all-cause mortality, stroke, and rehospitalization at 1 year. Secondary endpoints were the individual components of the primary endpoint at 1 year. To adjust for baseline differences, nearest neighbor propensity score matching was used. After matching (702 pairs), baseline characteristics were similar between groups. Device success was more common in the neo2 group (87.5% vs 82.3%; P = 0.007), irrespective of matching. DP mean after the procedure was higher for Ultra (13 mm Hg [Q1-Q3: 10-15 mm Hg] vs 8 mm Hg [Q1-Q3: 6-11] mm Hg; P < 0.001). Rates of paravalvular leakage, device embolization, and multiple valve implantations were more common in the neo2 arm, whereas major cardiac structural complications and major vascular complications occurred more frequently in the Ultra group. All other in-hospital complication rates were similar between the 2 groups. At 1 year, the cumulative incidence of the primary endpoint (14.1% for neo2 vs 14.5% for Ultra; P = 0.819) was similar between the groups. Likewise, the individual components showed no difference between the groups. Despite differing immediate results, the outcomes at 1 year, including the composite of all-cause mortality, stroke, or hospitalization, were similar for neo2 and Ultra transcatheter heart valves.
1 May 2024 in Circulation: Cardiovascular Interventions
BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm 2 ) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, −4.4 to −7.2]; P =0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, −5.0% [95% CI, −13.2 to 3.1]; P =0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0–13.9]; P <0.001) and mean transvalvular gradient ≥20 mm Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8–17.1]; P <0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, −10.1 to −2.7]; P =0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, −1.8% [95% CI, −4.1 to 0.4]; P =0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48–1.77]; P =0.817). CONCLUSIONS: In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.
Background: Severe calcification of the ascending aorta increases the peri-operative risk for neurological complications in patients with severe aortic stenosis. Transcatheter aortic valve implantation (TAVI) seems to be an optimal treatment option in these patients. However, the impact of the extent of aortic calcification on procedural and neurological outcomes during TAVI is unclear. Methods: Data from 3010 patients with severe native aortic valve stenosis treated with ACURATE neo/neo2 from May 2012 to July 2022 were evaluated and matched by 2-to-1 nearest-neighbor matching to identify one patient with porcelain aorta (PA) (n = 492) compared with two patients without PA (n = 984). PA was additionally subdivided into circumferential (classic PA) (n = 89; 3.0%) and non-circumferential (partial PA) (n = 403; 13.4%) calcification. We compared outcomes according to VARC-3 criteria among patients with and without PA and identified predictors for occurrence of stroke in the overall population. Results: Technical success (88.5% vs. 87.4%, p = 0.589) and device success at 30 days (82.3% vs. 81.5%, p = 0.755) after transcatheter ACURATE neo/neo2 implantation according to VARC-3 definition was high and did not differ between non-calcified aortas or PA. The rate of in-hospital complications according to VARC-3-definitions was low in both groups. Rates of all stroke (3.2% (n = 31) vs. 2.6% (n = 13), p = 0.705) or transitory ischemic attacks (1.1% vs. 1.2%, p = 1.000) did not differ significantly. Thirty-day all-cause mortality did not differ (3.0% vs. 3.2%, RR 1.1; p = 0.775). Overall device migration/embolization (OR 5.0 ), severe bleeding (OR 1.79 ), and major structural cardiac complications (OR 3.37 ) were identified as independent predictors for in-hospital stroke in a multivariate analysis after implantation of ACURATE neo/neo2. Conclusion: A porcelain aorta does not increase the risk of neurological complications after transfemoral ACURATE neo/neo2 implantation. Based on these findings, transfemoral ACURATE neo/neo2 implantation is safe in these particularly vulnerable patients.
Background: During the last years, several transcatheter aortic heart valves entered the clinical market and are commercially available. The prostheses differ regarding several technical and functional aspects. However, little is known regarding head-to-head comparative data of the ACURATE neo and the PORTICO valve prostheses. Objectives: The aim of this study was to compare two self-expanding transcatheter aortic heart valves (THV), the ACURATE neo and the PORTICO, with regard to in-hospital and 30-day outcomes, as well as early device failures. Methods: A total of 1591 consecutive patients with severe native aortic valve stenosis from two centers were included in the analyses and matched by 1:1 nearest neighbor matching to identify one patient treated with PORTICO (n = 344) for each patient treated with ACURATE neo (n = 344). Results: In-hospital complications were comparable between both valves, including any kind of stroke (ACURATE neo = 3.5% vs. PORTICO = 3.8%; p = 1.0), major vascular complications (ACURATE neo = 4.5% vs. PORTICO = 5.4%; p = 0.99) or life-threatening bleeding (ACURATE neo = 1% vs. PORTICO = 2%; p = 0.68). The rate of device failure defined by the VARC-2 criteria were comparable, including elevated gradients and moderate-to-severe paravalvular leakage (ACURATE neo = 7.3% vs. PORTICO = 7.6%; p = 1.0). However, the need for permanent pacemaker implantation (PPI) was significantly more frequent after the use of PORTICO THV (9.5% vs. 18.7%; p = 0.002). Conclusions: In this two-center case-matched comparison, short-term clinical and hemodynamic outcomes showed comparable results between PORTICO and ACURATE neo prostheses. However, PORTICO was associated with a significant higher incidence of PPI.