Kang Xia

Kang Xia


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
KXKang Xia
Kang Xia
XCXianglei Chen
Xianglei Chen
XCXuedong Chang
Xuedong Chang
CLchongshuai liu
chongshuai liu
LGLiwei Guo
Liwei Guo
JZJianfang Zhou
Jianfang Zhou
Stroke and related complications such as hemiplegia and disability create huge burdens for human society in the 21st century, which leads to a great need for rehabilitation and daily life assistance. To address this issue, continuous efforts are devoted in human–machine interaction (HMI) technology, which aims to capture and recognize users’ intentions and fulfil their needs via physical response. Based on the physiological structure of the human hand, a dimension-adjustable linkage-driven hand exoskeleton with 10 active degrees of freedom (DoFs) and 3 passive DoFs is proposed in this study, which grants high-level synergy with the human hand. Considering the weight of the adopted linkage design, the hand exoskeleton can be mounted on the existing up-limb exoskeleton system, which greatly diminishes the burden for users. Three rehabilitation/daily life assistance modes are developed (namely, robot-in-charge, therapist-in-charge, and patient-in-charge modes) to meet specific personal needs. To realize HMI, a thin-film force sensor matrix and Inertial Measurement Units (IMUs) are installed in both the hand exoskeleton and the corresponding controller. Outstanding sensor–machine synergy is confirmed by trigger rate evaluation, Kernel Density Estimation (KDE), and a confusion matrix. To recognize user intention, a genetic algorithm (GA) is applied to search for the optimal hyperparameters of a 1D Convolutional Neural Network (CNN), and the average intention-recognition accuracy for the eight actions/gestures examined reaches 97.1% (based on K-fold cross-validation). The hand exoskeleton system provides the possibility for people with limited exercise ability to conduct self-rehabilitation and complex daily activities.

18 July 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
KXKang Xia
Kang Xia
HZHaifei Zhan
Haifei Zhan
XZXinjie Zhang
Xinjie Zhang
ZLZhiyong Li
Zhiyong Li
2D Titanium carbide MXenes with a structural formula recognized as Tin+1Cn have attracted attention from both the academic and industry fields due to their intriguing mechanical properties and appealing potential in a variety of areas such as nano-electronic circuits/devices, bio sensors, energy storage and reinforcing material for composites. Based on mutli-body comb3 (third-generation Charge-Optimized Many-Body) potential, this work investigated the impact resistance of monolayer Tin+1Cn nanosheets (namely, Ti2C Ti3C2 and Ti4C3) under hypervelocity up to 7 km/s. The deformation behavior and the impact resist mechanisms of Tin+1Cn nanosheets were assessed. Penetration energy is found to positively correlate with the number of titanium atom layer (n). However, in tracking atomic Von Mises stress distribution, Ti2C exhibits the most significant elastic wave propagation velocity among the examined nanosheets, suggesting the highest energy delocalization rate and stronger energy dissipation via deformation prior to bond break. Consistently, Ti2C presents superior specific penetration energy due its Young’s-modulus-to-density ratio, followed by Ti3C2 and Ti4C3, suggesting an inverse correlation between the titanium atom layer number and specific penetration energy. This study provides a fundamental understanding of the deformation and penetration mechanisms of titanium carbide MXene nanosheets under impact, which could be beneficial to facilitating their emerging impact protection applications.

4 July 2025 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
KXKang Xia
Kang Xia
XCXue-Dong Chang
Xue-Dong Chang
CLChong-Shuai Liu
Chong-Shuai Liu
YYYu-Hang Yan
Yu-Hang Yan
HSHan Sun
Han Sun
XWXin-Wei Wang
Xin-Wei Wang
Stroke and its related complications, place significant burdens on human society in the twenty-first century, and lead to substantial demands for upper limb rehabilitation. To fulfill the rehabilitation needs, human–machine interaction (HMI) technology strives continuously. Depends on the involvement of subject, HMI strategy can be classified as passive or active. Compare to passive modalities, active strategies are believed to be more effective in promoting neuroplasticity and motor recovery for post-stroke survivors in sub-acute and chronic phase. However, post-stroke survivors usually experience weak upper arms, limited range of motion (ROM) and involuntary excessive movement patterns. Distinguishing between complex subtle motion intentions and excessive involuntary movements in real-time remains a challenge in current research, which impedes the application of active HMI strategies in clinical practice. An Up-limb Rehabilitation Device and Utility System (UarDus) is proposed along with 3 HMI strategies namely robot-in-charge, therapist-in-charge and patient-in-charge. Based on physiological structure of human upper-limb and scapulohumeral rhythm (SHR) of shoulder, a base exoskeleton with 14 degrees of freedoms (DoFs) is designed as foundation of the 3 strategies. Passive robot-in-charge and therapist-in-charge strategies provides fully-assisted rehabilitation options. The active patient-in-charge strategy incorporates data acquisition matrices and a new deep learning model, which is developed based on Convolutional Neural Network (CNN) and Transformer structure, aims to capture subtle motion intentions. Motors’ current is monitored and the surge in the current is identified adopting Discrete Wavelet Transform (DWT) method for safety concerns. Kinematically, the work space of the base exoskeleton is presented first. Utilizing motion capture technology, the glenohumeral joint (GH) centers of both human and exoskeleton exhibit well-matched motion curves, suggesting a comfortable dynamic wear experience. For robot-in-charge and therapist-in-charge strategy, the desired and measured angle-time curve present good correlation, with low phase difference, which serve the purpose of real-time control. Featuring the patient-in-charge strategy, Kernel Density Estimation (KDE) result suggesting reasonable sensor-machine-human synergy. Applying K-fold (K = 10) cross-validation method, the classification accuracy of the proposed model with outstanding response time achieves an average of 99.7% for the designated 15 actions, signifies its capability for subtle motion intention recognition in real-time. Additionally, signal surge is easily identified with DWT. An upper-limb exoskeleton hardware device named UarDus is constructed, along with three HMI modalities, offering both passive and active rehabilitation approaches. The proposed system is validated through a proof-of-concept study on a subject who underwent a craniotomy for a hemorrhagic stroke, demonstrating the possibility for post-stroke individuals to engage in safe, personalized rehabilitation training in real-time, with a dynamically comfortable wear experience.

20 November 2022 in Metals
Verified
Journal Article
Open access
PDF file
KXKang Xia
Kang Xia
HZHaifei Zhan
Haifei Zhan
JSJian-Li Shao
Jian-Li Shao
Jiaqiu WangJiaqiu Wang
Jiaqiu Wang
ZZZhuoqun Zheng
Zhuoqun Zheng
ZLZhiyong Li
Zhiyong Li
Titanium carbides attract attention from both academic and industry fields because of their intriguing mechanical properties and proven potential as appealing candidates in the variety of fields such as nanomechanics, nanoelectronics, energy storage and oil/water separation devices. A recent study revealed that the presence of Ti8C5 not only improves the impact strength of composites as coatings, but also possesses significant strengthening performance as an interlayer material in composites by forming strong bonding between different matrices, which sheds light on the design of impact protection composite materials. To further investigate the impact resistance and strengthening mechanism of Ti8C5, a pilot Molecular Dynamics (MD) study utilizing comb3 potential is carried out on a Ti8C5 nanosheet by subjecting it to hypervelocity impacts. The deformation behaviour of Ti8C5 and the related impact resist mechanisms are assessed in this research. At a low impact velocity ~0.5 km/s, the main resonance frequency of Ti8C5 is 11.9 GHz and its low Q factor (111.9) indicates a decent energy damping capability, which would eliminate the received energy in an interfacial reflection process and weaken the shock waves for Ti8C5 strengthened composites. As the impact velocity increases above the threshold of 1.8 km/s, Ti8C5 demonstrates brittle behaviour, which is signified by its insignificant out-of-plane deformation prior to crack initiation. When tracking atomic Von Mises stress distribution, the elastic wave propagation velocity of Ti8C5 is calculated to be 5.34 and 5.90 km/s for X and Y directions, respectively. These figures are inferior compared with graphene and copper, which indicate slower energy delocalization rates and thus less energy dissipation via deformation is expected prior to bond break. However, because of its relatively small mass density comparing with copper, Ti8C5 presents superior specific penetration. This study provides a fundamental understanding of the deformation and penetration mechanisms of titanium carbide nanosheets under impact, which is crucial in order to facilitate emerging impact protection applications for titanium carbide-related composites.

24 January 2025
Verified
Book Chapter
Open access
PDF file
XCXianglei Chen
Xianglei Chen
KXKang Xia
Kang Xia
JZJianfang Zhou
Jianfang Zhou
HSHan Sun
Han Sun
YWYimin Wang
Yimin Wang
With the increasing aging population in China and the trend of younger onset of elderly diseases, more middle-aged and elderly people are suffering from stroke and related complications. Considering the increasing needs in rehabilitation service, exoskeletons for rehabilitation training have become a urgent solution. This article starts by analyzing the finger skeleton and designs a dorsal-style hand exoskeleton which assists patients in individual rehabilitation training for each finger, enabling them to perform simple grasping activities in daily life. Moreover, by using a single active driver, the exoskeleton can systematically drive the two adjacent joints of a patient's finger, ensuring that their movement aligns with the typical grasping patterns of a healthy individual. This design is more beneficial for the patient's rehabilitation. Finally, a comparison is made between the range of motion of the finger in a healthy state and when wearing the exoskeleton to ensure the safety of the exoskeleton.

24 January 2025
Verified
Book Chapter
Open access
PDF file
CLchongshuai liu
chongshuai liu
KXKang Xia
Kang Xia
JZJianfang Zhou
Jianfang Zhou
HSHan Sun
Han Sun
YWYimin Wang
Yimin Wang
Upper limb rehabilitation exoskeleton can be a good substitute for professional therapists in rehabilitation training for stroke patients, but few devices can accurately obtain the upper limb rehabilitation movements of therapists or patients on the healthy side to guide the rehabilitation exoskeleton in passive rehabilitation of patients. In this paper, a 10-DOF exoskeletal master device is proposed, which includes all the degrees of freedom of upper limb, and is improved from two aspects of kinematic analysis and structural design. By studying the motion of the whole upper limb, especially the shoulder joint, the complete upper limb motion chain is proposed in this paper, and the feasibility is verified by kinematics analysis. Then the structure design is carried out and introduced in detail. Finally, genetic algorithm was used to optimize the structural parameters of pHRI, which provided a reference for Physical human–robot-interface (pHRI) transplantation to different exoskeleton devices.