Michael Oldham

Dr. Michael Oldham

orcid

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2010 in Journal of Aerosol Medicine and Pulmonary Drug Delivery
Verified
Journal Article
Closed access
PBPeter R. Byron
Peter R. Byron
MHMichael Hindle
Michael Hindle
CLCarlos F. Lange
Carlos F. Lange
PLP. Worth Longest
P. Worth Longest
DMDonald McRobbie
Donald McRobbie
WFWarren H. Finlay
Warren H. Finlay
In order to answer the question “what research remains to be done?” we review the current state of the art in pharmaceutical aerosol deposition modeling and explore possible in vivo– in vitro correlations (IVIVC) linking drug deposition in the human lung to predictions made using in vitro physical airway models and in silico computer models. The use of physical replicas of portions of the respiratory tract is considered, alongside the advantages and disadvantages of the different imaging methods used to obtain their dimensions. The use of airway replicas to determine drug deposition in vitro is discussed and compared with the predictions from different empirical curve fits to long-standing in vivo deposition data for monodisperse aerosols. The use of improved computational models and three-dimensional computational fluid dynamics (CFD) to predict aerosol deposition within the respiratory tract is examined. CFD's ability to predict both drug deposition from pharmaceutical aerosol sprays and powder behavior in dry powder inhalers is examined; both were highlighted as important areas for future research. Although the authors note the abilities of current in vitro and in silico methods to predict in vivo data, a number of limitations remain. These include our present inability to either image or replicate all but the most proximal airways in sufficient spatial and temporal detail to allow full capture of the fluid and aerosol mechanics in these regions. In addition, the highly complex microscale behavior of aerosols within inhalers and the respiratory tract places extreme computational demands on in silico methods. When the complexity of variations in respiratory tract geometry is associated with additional factors such as breathing pattern, age, disease state, postural position, and patient-device interaction are all considered, it is clear that further research is required before the prediction of all aspects of inhaled pharmaceutical aerosol deposition is possible.

1 February 2011 in Journal of Women's Health
Verified
Journal Article
Open access
BNBarbara B. North
Barbara B. North
MOMichael Oldham
Michael Oldham
Background: Menstrual cups have been available for decades, but their use is limited by bulky design and the need for multiple sizes. The Softcup ® (Instead, Inc., San Diego, CA) is a simple single-size disposable over-the-counter (OTC) menstrual cup that compresses to tampon shape to facilitate insertion and can be worn during coitus. This report describes preclinical evaluation, clinical testing, and postmarketing monitoring of the Softcup. Methods: Preclinical testing complied with U.S. Food and Drug Administration (FDA) guidelines and used standard United States Pharmacopoeia methodologies for assessment of potential toxicity. Clinical testing enrolled 406 women in seven U.S. centers. A detailed written questionnaire assessed safety, acceptability, and effectiveness for menstrual collection. Study safety parameters included pelvic examinations, Pap smears, colposcopy, urinalysis, vaginal pH, wet mounts, gram stain, and vaginal microflora cultures. Postmarketing surveillance of over 100 million Softcups has been conducted by the manufacturer and by the FDA Medwatch system. Results: No toxicity or mutagenicity was observed in preclinical evaluations. In clinical testing, after three cycles of cup use, 37% of subjects rated the cup as better than, 29% as worse than, and 34% as equal to pads or tampons. The cup was preferred for comfort, dryness, and less odor. Cups received lower ratings for disposal and convenience. Eighty-one percent of enrolled women were able to insert and remove their first cup using only written instructions. Use difficulties resulting in study discontinuations included cramping (1%), leakage (1%), and improper fit (3%). No safety parameters were adversely affected. No significant health risks were reported during postmarketing surveillance. Conclusions: These results demonstrate that a single-size vaginal device has no significant health risks and is acceptable to many women without the need for fitting or other medical services.

1 March 2008 in Journal of Aerosol Medicine and Pulmonary Drug Delivery
Verified
Journal Article
Open access
RPRobert F. Phalen
Robert F. Phalen
MOMichael Oldham
Michael Oldham
RWRonald K. Wolff
Ronald K. Wolff
Animal models are essential for understanding the fates and effects of inhaled materials, because invasive methods are frequently necessary to provide the desired information. Because of the variability in humans of particle deposition, clearance, and effects, numerous animal models have been used in inhalation studies. Furthermore, humans are not typical mammals in some ways that affect inhalation phenomena. Humans have less fur, longer gestation and life times, simplified nasal structure, and symmetric bronchial branching in relation to other mammals. However, experience, plus the genetic similarity among mammals, underpins the use of animal models. Mammals are varied with respect to their inhaled particle deposition and clearance phenomena. Total inhaled aerosol deposition probability versus particle-size curves are qualitatively similar for various mammals of similar body mass, despite airway anatomy differences. However, more species variation is seen in regional particle deposition curves, complicating aerosol study design. The rates of clearance of deposited slowly dissolving particles are animal species dependent, apparently due to differences in gross, subgross, and cellular respiratory tract biology. Clearance rates for rapidly dissolving particles are not strongly species dependent. Inhalation toxicology studies require several animal species. Rodents are among the most frequently used, but for studies of lung development, diseases, exercise, etc., and for extrapolation to humans, larger mammals are also needed. Fortunately, the research database, and excellent monographs on inhalation phenomena provide ample guidance for study design.

2 January 2016 in Inhalation Toxicology
Verified
Journal Article
Open access
PDF file
MWMichael S. Werley
Michael S. Werley
DKDan J. Kirkpatrick
Dan J. Kirkpatrick
MOMichael Oldham
Michael Oldham
AJAnn M. Jerome
Ann M. Jerome
TLTimothy B. Langston
Timothy B. Langston
WMWillie J. Mckinney
Willie J. Mckinney
A prototype electronic cigaret device and three formulations were evaluated in a 90-day rat inhalation study followed by a 42-day recovery period. Animals were randomly assigned to groups for exposure to low-, mid- and high-dose levels of aerosols composed of vehicle (glycerin and propylene glycol mixture); vehicle and 2.0% nicotine; or vehicle, 2.0% nicotine and flavor mixture. Daily targeted aerosol total particulate matter (TPM) doses of 3.2, 9.6 and 32.0 mg/kg/day were achieved by exposure to 1 mg/L aerosol for 16, 48 and 160 min, respectively. Pre-study evaluations included indirect ophthalmoscopy, virology and bacteriological screening. Body weights, clinical observations and food consumption were monitored weekly. Plasma nicotine and cotinine and carboxyhemoglobin levels were measured at days 28 and 90. After days 28, 56 and 90, lung function measurements were obtained. Biological endpoints after 90-day exposure and 42-day recovery period included clinical pathology, urinalysis, bronchoalveolar fluid (BALF) analysis, necropsy and histopathology. Treatment-related effects following 90 days of exposure included changes in body weight, food consumption and respiratory rate. Dose-related decreases in thymus and spleen weights, and increased BALF lactate dehydrogenase, total protein, alveolar macrophages, neutrophils and lung weights were observed. Histopathology evaluations revealed sporadic increases in nasal section 1–4 epithelial hyperplasia and vacuolization. Following the recovery period, effects in the nose and BALF were persistent while other effects were resolved. The no observed effect level based upon body weight decreases is considered to be the mid-dose level for each formulation, equivalent to a daily TPM exposure dose of approximately 9.6 mg/kg/day.

12 October 2010 in Inhalation Toxicology
Verified
Journal Article
Open access
PDF file
RPRobert F. Phalen
Robert F. Phalen
Loyda MendezLoyda Mendez
Loyda Mendez
MOMichael Oldham
Michael Oldham
Dosimetry provides information linking environmental exposures to sites of deposition, removal from these sites, and translocation of deposited materials. Dosimetry also aids in extrapolating laboratory animal and in vitro data to humans. Recent progress has shed light on: properties of particles in relation to their fates in the body; influence of age, gender, body size, and lung diseases on inhaled particle doses; particle movement to the brain via the olfactory nerves; and particle deposition hot spots in the respiratory tract. Ultrafine size has emerged as an important dosimetric characteristic. Particle count, composition, and surface properties are recognized as potentially important toxicology-related considerations. Differences in body size influence airway sizes, inhaled particle deposition, specific ventilation, and specific doses (e.g. per unit body mass). Related to body size, age, gender, species, and strain are also dosimetric considerations. Diseases, such as chronic obstructive pulmonary disease (COPD) and bronchitis, produce uneven doses within the respiratory tract. Traditional concepts of the translocation and clearance of deposited particles have been challenged. Ultrafine particles can translocate to the brain via olfactory nerves, and from the lung to other organs. The clearance rates of particles from tracheobronchial airways are slowed by respiratory tract infections, but newer evidence implies that slow particle clearance from this region also exists in healthy lungs. Finally, hot spots of particle deposition are seen in hollow models, lung tissue, and dosimetric simulations. Local doses to groups of epithelial cells can be much greater than those to surrounding cells. The new insights challenge dosimetry scientists.

1 April 2020 in Regulatory Toxicology and Pharmacology
Verified
Journal Article
Open access
IGI. Gene Gillman
I. Gene Gillman
APAlexander S.C. Pennington
Alexander S.C. Pennington
KHKathy E. Humphries
Kathy E. Humphries
MOMichael Oldham
Michael Oldham
1,2-Propylene glycol and glycerin, principal components of e-liquids, can thermally degrade to form acetaldehyde, acrolein, and formaldehyde when heated in electronic nicotine delivery systems (ENDS). Recently the flavors in e-liquids were suggested to be the major source of these aldehydes. We used the same 10 ENDS devices to test 5 e-liquid formulations (four flavored & one corresponding non-flavored) and measured device mass loss and levels of acetaldehyde, acrolein, and formaldehyde (30 replicate measurements per formulation). Despite finding reasonable variability in measurements of device mass loss, two out of 10 ENDS devices tested produced outlier values for aerosol levels acetaldehyde, acrolein, and formaldehyde. After removing these devices from further analysis, acceptable variability (≤20% RSD) in aerosol levels of acetaldehyde, and formaldehyde were found. The flavored formulations tested resulted in a consistent and selective increase of 150%-200% in acetaldehyde, no increase or decrease in acrolein and depending on the flavor formulation, an increase, a decrease or no change in formaldehyde levels. Comparison of our results to the literature illustrates the need for development of a standardized ENDS testing protocol. Our results further support that device variability must be fully characterized and considered before assessing the impact of e-liquid formulations.