I. Gene Gillman

Dr. I. Gene Gillman

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Regulatory Toxicology and Pharmacology
Verified
Journal Article
Open access
IGI. Gene Gillman
I. Gene Gillman
KKK.A. Kistler
K.A. Kistler
ESE.W. Stewart
E.W. Stewart
APA.R. Paolantonio
A.R. Paolantonio
The study objective was to determine the effect of variable power applied to the atomizer of refillable tank based e-cigarette (EC) devices. Five different devices were evaluated, each at four power levels. Aerosol yield results are reported for each set of 25 EC puffs, as mass/puff, and normalized for the power applied to the coil, in mass/watt. The range of aerosol produced on a per puff basis ranged from 1.5 to 28 mg, and, normalized for power applied to the coil, ranged from 0.27 to 1.1 mg/watt. Aerosol samples were also analyzed for the production of formaldehyde, acetaldehyde, and acrolein, as DNPH derivatives, at each power level. When reported on mass basis, three of the devices showed an increase in total aldehyde yield with increasing power applied to the coil, while two of the devices showed the opposite trend. The mass of formaldehyde, acetaldehyde, and acrolein produced per gram of total aerosol produced ranged from 0.01 to 7.3 mg/g, 0.006 to 5.8 mg/g, and <0.003 to 0.78 mg/g, respectively. These results were used to estimate daily exposure to formaldehyde, acetaldehyde, and acrolein from EC aerosols from specific devices, and were compared to estimated exposure from consumption of cigarettes, to occupational and workplace limits, and to previously reported results from other researchers.

Konstantinos FarsalinosKonstantinos Farsalinos
Konstantinos Farsalinos
IGI. Gene Gillman
I. Gene Gillman
MMMatt Melvin
Matt Melvin
APAmelia Paolantonio
Amelia Paolantonio
WGWendy J. Gardow
Wendy J. Gardow
VVVassilis Voudris
Vassilis Voudris
Background. Some electronic cigarette (EC) liquids of tobacco flavour contain extracts of cured tobacco leaves produced by a process of solvent extraction and steeping. These are commonly called Natural Extract of Tobacco (NET) liquids. The purpose of the study was to evaluate nicotine levels and the presence of tobacco-derived toxins in tobacco-flavoured conventional and NET liquids. Methods. Twenty-one samples (10 conventional and 11 NET liquids) were obtained from the US and Greek market. Nicotine levels were measured and compared with labelled values. The levels of tobacco-derived chemicals were compared with literature data on tobacco products. Results. Twelve samples had nicotine levels within 10% of the labelled value. Inconsistency ranged from −21% to 22.1%, with no difference observed between conventional and NET liquids. Tobacco-specific nitrosamines (TSNAs) were present in all samples at ng/mL levels. Nitrates were present almost exclusively in NET liquids. Acetaldehyde was present predominantly in conventional liquids while formaldehyde was detected in almost all EC liquids at trace levels. Phenols were present in trace amounts, mostly in NET liquids. Total TSNAs and nitrate, which are derived from the tobacco plant, were present at levels 200–300 times lower in 1 mL of NET liquids compared to 1 gram of tobacco products. Conclusions. NET liquids contained higher levels of phenols and nitrates, but lower levels of acetaldehyde compared to conventional EC liquids. The lower levels of tobacco-derived toxins found in NET liquids compared to tobacco products indicate that the extraction process used to make these products did not transfer a significant amount of toxins to the NET. Overall, all EC liquids contained far lower (by 2–3 orders of magnitude) levels of the tobacco-derived toxins compared to tobacco products.

1 October 1999 in Chemical Research in Toxicology
Verified
Journal Article
Closed access
IGI. Gene Gillman
I. Gene Gillman
TCT. Nicole Clark
T. Nicole Clark
RMRichard A. Manderville
Richard A. Manderville

Konstantinos FarsalinosKonstantinos Farsalinos
Konstantinos Farsalinos
IGI. Gene Gillman
I. Gene Gillman
Konstantinos PoulasKonstantinos Poulas
Konstantinos Poulas
VVVassilis Voudris
Vassilis Voudris
Introduction: Although electronic cigarette (EC) liquids contain low levels of tobacco-specific nitrosamines (TSNAs), studies evaluating the levels emitted to the aerosol are scarce. The purpose of this study was to compare the levels of TSNAs between liquids and generated aerosol. Methods: Three EC liquids were obtained from the market. An additional (spiked) sample was prepared by adding known amounts of standard TSNAs solutions to one of the obtained liquids. N-nitrosonornicotine (NNN), N-nitrosoanatabine (NAT), N-nitrosoanabasine (NAB) and 4-(methylnitrosamino)1-(3-pyridyl)-1-butanone (NNK) were measured. Three 100-puff sets from each liquid were trapped in filter pads and were subsequently analyzed for the presence of TSNAs. The expected levels of TSNAs (calculated based on the liquid consumption) were compared with the measured levels in the aerosol. Results: Only NAB was found at trace levels in two commercial liquids (1.2 and 2.3 ng/g), while the third contained 1.5 ng/g NAB and 7.7 ng/g NNN. The 100-puff sets resulted in 336–515 mg liquid consumption, with no TSNAs being detected in the aerosol. The spiked sample contained 42.0–53.9 ng/g of each of the TSNAs. All TSNAs were detected in the aerosol with the measured levels being statistically similar to the expected amounts. A significant correlation between expected and measured levels of TSNAs in the aerosol was found (r = 0.83, p < 0.001). Conclusion: The findings of this study show that exposure of EC users to TSNAs can be accurately assessed based on the levels present in the liquid, without the need to analyze the aerosol.


1 April 2020 in Regulatory Toxicology and Pharmacology
Verified
Journal Article
Open access
IGI. Gene Gillman
I. Gene Gillman
APAlexander S.C. Pennington
Alexander S.C. Pennington
KHKathy E. Humphries
Kathy E. Humphries
MOMichael Oldham
Michael Oldham
1,2-Propylene glycol and glycerin, principal components of e-liquids, can thermally degrade to form acetaldehyde, acrolein, and formaldehyde when heated in electronic nicotine delivery systems (ENDS). Recently the flavors in e-liquids were suggested to be the major source of these aldehydes. We used the same 10 ENDS devices to test 5 e-liquid formulations (four flavored & one corresponding non-flavored) and measured device mass loss and levels of acetaldehyde, acrolein, and formaldehyde (30 replicate measurements per formulation). Despite finding reasonable variability in measurements of device mass loss, two out of 10 ENDS devices tested produced outlier values for aerosol levels acetaldehyde, acrolein, and formaldehyde. After removing these devices from further analysis, acceptable variability (≤20% RSD) in aerosol levels of acetaldehyde, and formaldehyde were found. The flavored formulations tested resulted in a consistent and selective increase of 150%-200% in acetaldehyde, no increase or decrease in acrolein and depending on the flavor formulation, an increase, a decrease or no change in formaldehyde levels. Comparison of our results to the literature illustrates the need for development of a standardized ENDS testing protocol. Our results further support that device variability must be fully characterized and considered before assessing the impact of e-liquid formulations.