PING ZHANG

Dr. PING ZHANG


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
QYQian Yu
Qian Yu
PZPING ZHANG
PING ZHANG
PZPing Zhang
Ping Zhang
ZXZhifeng Xu
Zhifeng Xu
XHXiulong He
Xiulong He
LHLin He
Lin He
The dissipation dynamics and residue of pyrazosulfuron-ethyl, bensulfuron-methyl, acetochlor, and butachlor in paddy fields at Good Agricultural Practices (GAP) condition were carefully investigated in this study. The four herbicides’ residues were determined based on a quick, easy, cheap, rugged, safe (QuEChERS) method coupled with HPLC-MS/MS and GC-MS. The limit of detection (LOD) for pyrazosulfuron-ethyl, bensulfuron-methyl, acetochlor, and butachlor in all matrices ranged from 0.04–1.0 ng. The limit of quantification (LOQ) of the four herbicides ranged from 0.01–0.1 mg/kg. Moreover, the average recoveries of the four herbicides ranged from 78.9–108% with relative standard deviations (RSDs) less than 15% at three different fortified levels for different matrices. The dissipation results indicated that the average half-lives (t1/2) of the four herbicides in soil were in the range of 3.5–17.8 days, and more than 95% of the four herbicides dissipated within 5 days in water. Furthermore, the final residues of the four herbicides were all below the LOQ at harvest time. Such results highlight the dissipation dynamics and residue of the four herbicides in a rice cropping system and contribute to risk assessment as well as scientific guidance on the proper and safe application of herbicides in paddy fields.

Verified
Journal Article
Open access
PDF file
PZPING ZHANG
PING ZHANG
Wentao ZhuWentao Zhu
Wentao Zhu
DWDi Wang
Di Wang
JYJin Yan
Jin Yan
YWYao Wang
Yao Wang
LHLin He
Lin He
In this study, an integrative high-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry (HPLC-QTOF) based metabolomics approach was performed to evaluate the enantioselective metabolic perturbations in MCF-7 cells after treatment with R-metalaxyl and S-metalaxyl, respectively. Untargeted metabolomics profile, multivariate pattern recognition, metabolites identification, and pathway analysis were determined after metalaxyl enantiomer exposure. Principal component analysis (PCA) and partitial least-squares discriminant analysis (PLS-DA) directly reflected the enantioselective metabolic perturbations induced by metalaxyl enantiomers. On the basis of multivariate statistical results, a total of 49 metabolites including carbohydrates, amino acids, nucleotides, fatty acids, organic acids, phospholipids, indoles, derivatives, etc. were found to be the most significantly changed metabolites and metabolic fluctuations caused by the same concentration of R-metalaxyl and S-metalaxyl were enantioselective. Pathway analysis indicated that R-metalaxyl and S-metalaxyl mainly affected the 7 and 10 pathways in MCF-7 cells, respectively, implying the perturbed pathways induced by metalaxyl enantiomers were also enantioselective. Furthermore, the significantly perturbed metabolic pathways were highly related to energy metabolism, amino acid metabolism, lipid metabolism, and antioxidant defense. Such results provide more specific insights into the enantioselective metabolic effects of chiral pesticides in breast cancer progression, reveal the underlying mechanisms, and provide available data for the health risk assessments of chiral environmental pollutants at the molecular level.

Verified
Journal Article
Open access
PDF file
PZPING ZHANG
PING ZHANG
SWSheng Wang
Sheng Wang
YHYuhan He
Yuhan He
YXYangyang Xu
Yangyang Xu
DSDongmei Shi
Dongmei Shi
LHLin He
Lin He
Although metabolic perturbations are sensitive indicators for low-dose toxic effects, the metabolic mechanisms affected by rac-metalaxyl and metalaxyl-M in mammals from a metabolic profiling perspective remain unclear. In this study, the metabolic perturbations and toxic effects of rac-metalaxyl and metalaxyl-M in mice were carefully investigated using integrative nuclear magnetic resonance (NMR) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) based metabolomics. Histopathology, NMR-based untargeted urine profile, multivariate pattern recognition, metabolite identification, pathway analysis, UPLC-MS/MS based targeted serum amino acids, and tryptophan pathway analysis were determined after rac-metalaxyl and metalaxyl-M exposure, individually. Histopathology indicated that metalaxyl-M induced greater hepatocellular inflammatory, necrosis, and vacuolation in mice than rac-metalaxyl at the same exposure dosage. The metabolic perturbations induced by rac-metalaxyl and metalaxyl-M were directly separated using partial least-squares discriminant analysis (PLS-DA). Furthermore, metabolite identification and pathway analysis indicated that rac-metalaxyl mainly induced ten urine metabolite changes and four pathway fluctuations. However, metalaxyl-M induced 19 urine metabolite changes and six pathway fluctuations. Serum amino acids and tryptophan pathway metabolite changes induced by rac-metalaxyl and metalaxyl-M were also different even at the same exposure level. Such results may provide specific insight into the metabolic perturbations and toxic effects of rac-metalaxyl and metalaxyl-M, and contribute to providing available data for health risk assessments of rac-metalaxyl and metalaxyl-M at a metabolomics level.

9 July 2020 in Molecules
Verified
Journal Article
Open access
PDF file
PZPING ZHANG
PING ZHANG
YHYuhan He
Yuhan He
SWSheng Wang
Sheng Wang
DSDongmei Shi
Dongmei Shi
YXYangyang Xu
Yangyang Xu
LHLin He
Lin He
The chiral separation of etoxazole enantiomers on Lux Cellulose-1, Lux Cellulose-3, Chiralpak IC, and Chiralpak AD chiral columns was carefully investigated by normal-phase high performance liquid chromatography and reverse-phase high performance liquid chromatography (HPLC). Hexane/isopropanol, hexane/n-butanol, methanol/water, and acetonitrile/water were used as mobile phase at a flow rate of 0.8 mL/min. The effects of chiral stationary phase, mobile phase component, mobile phase ratio, and temperature on etoxazole separation were also studied. Etoxazole enantiomers were baseline separated on Lux Cellulose-1, Chiralpak IC, and Chiralpak AD chiral columns, and partially separated on Lux Cellulose-3 chiral column under normal-phase HPLC. However, the complete separation on Lux Cellulose-1, Chiralpak IC, and partial separation on Chiralpak AD were obtained under reverse-phase HPLC. Normal-phase HPLC presented better resolution for etoxazole enantiomers than reverse-phase HPLC. Thermodynamic parameters, including ΔH and ΔS, were also calculated based on column temperature changes from 10 °C to 40 °C, and the maximum resolutions (Rs) were not always acquired at the lowest temperature. Furthermore, the optimized method was successfully applied to determine etoxazole enantiomers in cucumber, cabbage, tomato, and soil. The results of chiral separation efficiency of etoxazole enantiomers under normal-phase and reverse-phase HPLC were compared, and contribute to the comprehensive environmental risk assessment of etoxazole at the enantiomer level.

PZPING ZHANG
PING ZHANG
SWSheng Wang
Sheng Wang
DSDongmei Shi
Dongmei Shi
YXYangyang Xu
Yangyang Xu
FYFurong Yang
Furong Yang
LHLin He
Lin He
In the present study, the direct enantiomeric separation of hexythiazox enantiomers on Lux cellulose-1, Lux cellulose-2, Lux cellulose-3, Lux cellulose-4, Lux amylose-1 and Chirapak IC chiral columns were carefully investigated by reverse-phase high-performance liquid chromatography (RP-HPLC). Acetonitrile/water and methanol/water were used as mobile phase at a flow rate of 0.8 mL·min−1. The effects of chiral stationary phase, temperature, thermodynamic parameters, mobile phase component and mobile phase ratio on hexythiazox enantiomers separation were fully evaluated. Hexythiazox enantiomers received a baseline separation on the Lux cellulose-3 column with a maximum resolution of Rs = 2.09 (methanol/water) and Rs = 2.74 (acetonitrile/water), respectively. Partial separations were achieved on other five chiral columns. Furthermore, Lux amylose-1 and Chirapak IC had no separation ability for hexythiazox enantiomers when methanol/water was used as mobile phase. Temperature study indicated that the capacity factor (k) and resolution factor (Rs) decreased with column temperature increasing from 10 °C to 40 °C. The enthalpy (ΔH) and entropy (ΔS) involved in hexythiazox separation were also calculated and demonstrated the lower temperature contributed to better separation resolution. Moreover, the residue analytical method for hexythiazox enantiomers in the environment (soil and water) and vegetable (cucumber, cabbage and tomato) were also established with reliable accuracy and precision under reverse-phase HPLC condition. Such results provided a baseline separation method for hexythiazox enantiomers under reverse-phase conditions and contributed to an environmental and health risk assessment of hexythiazox at enantiomer level.