Lin He

Lin He


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2022 in Journal of Agricultural and Food Chemistry
Verified
Journal Article
Closed access
PZPing Zhang
Ping Zhang
FYFurong Yang
Furong Yang
LSLinlin Shi
Linlin Shi
CYCancan Yang
Cancan Yang
QCQi Chen
Qi Chen
LHLin He
Lin He

22 March 2024 in Science of The Total Environment
Verified
Journal Article
Closed access
PZPing Zhang
Ping Zhang
FYFurong Yang
Furong Yang
LRLulu Ran
Lulu Ran
CYCancan Yang
Cancan Yang
CTCan Tang
Can Tang
ZXZhifeng Xu
Zhifeng Xu

25 May 2025 in Pesticide Biochemistry and Physiology
Verified
Journal Article
Closed access
PZPing Zhang
Ping Zhang
XKXiaojiang Ke
Xiaojiang Ke
MZMengting Zhang
Mengting Zhang
CYCancan Yang
Cancan Yang
YCYiyun Cai
Yiyun Cai
LHLin He
Lin He

PZPING ZHANG
PING ZHANG
SWSheng Wang
Sheng Wang
DSDongmei Shi
Dongmei Shi
YXYangyang Xu
Yangyang Xu
FYFurong Yang
Furong Yang
LHLin He
Lin He
In the present study, the direct enantiomeric separation of hexythiazox enantiomers on Lux cellulose-1, Lux cellulose-2, Lux cellulose-3, Lux cellulose-4, Lux amylose-1 and Chirapak IC chiral columns were carefully investigated by reverse-phase high-performance liquid chromatography (RP-HPLC). Acetonitrile/water and methanol/water were used as mobile phase at a flow rate of 0.8 mL·min−1. The effects of chiral stationary phase, temperature, thermodynamic parameters, mobile phase component and mobile phase ratio on hexythiazox enantiomers separation were fully evaluated. Hexythiazox enantiomers received a baseline separation on the Lux cellulose-3 column with a maximum resolution of Rs = 2.09 (methanol/water) and Rs = 2.74 (acetonitrile/water), respectively. Partial separations were achieved on other five chiral columns. Furthermore, Lux amylose-1 and Chirapak IC had no separation ability for hexythiazox enantiomers when methanol/water was used as mobile phase. Temperature study indicated that the capacity factor (k) and resolution factor (Rs) decreased with column temperature increasing from 10 °C to 40 °C. The enthalpy (ΔH) and entropy (ΔS) involved in hexythiazox separation were also calculated and demonstrated the lower temperature contributed to better separation resolution. Moreover, the residue analytical method for hexythiazox enantiomers in the environment (soil and water) and vegetable (cucumber, cabbage and tomato) were also established with reliable accuracy and precision under reverse-phase HPLC condition. Such results provided a baseline separation method for hexythiazox enantiomers under reverse-phase conditions and contributed to an environmental and health risk assessment of hexythiazox at enantiomer level.

28 August 2025 in Pesticide Biochemistry and Physiology
Verified
Journal Article
Closed access
MZMengting Zhang
Mengting Zhang
YCYiyun Cai
Yiyun Cai
QTQixing Tang
Qixing Tang
CYCancan Yang
Cancan Yang
XKXiaojiang Ke
Xiaojiang Ke
PZPing Zhang
Ping Zhang