Real-time calibration of time-varying sensor position errors for flexible arrays is crucial to alleviate the array performance deterioration. Previous studies shown that sensor arrays of any shape can be self-calibrated except for the nominal linear array with small sensor position errors. In this paper, the self-calibration restriction of the nominal linear array is resolved, and an improved self-calibration algorithm is proposed to jointly estimate source DOAs and sensor positions. First, the identifiability of unknown parameters including sensor positions and source DOAs in array receiving model is analyzed. It is found that the failure of self-calibration for the nominal linear array is caused by the ambiguity of sensor position estimations under unknown source DOAs. Next, the accurate priori distance of one sensor pair in the array is introduced to solve such ambiguity. Moreover, the hybrid Cramér-Rao bound is also derived to verify the identifiability of unknown parameters under such distance priori. Finally, an improved sensor position self-calibration algorithm is proposed, which has lower computational complexity compared with the state-of-the-art self-calibration method. Numerical results demonstrate the self-calibration capability of the nominal linear array with small positional errors under the distance priori and the effectiveness of the proposed algorithm.
The state-of-the-art auxiliary calibration algorithms can perform comprehensive calibration of various array non-ideal characteristics, such as mutual coupling, gain/phase uncertainties, and sensor position errors, employing a set of cooperative calibration sources with known direction of arrival (DOA). However, the task of deploying calibration sources at precisely measured DOAs is complex. Otherwise, the calibration source DOA errors would seriously degrade the performance of these algorithms. In this paper, a dimension-reduction maximum likelihood calibration algorithm with inaccurate cooperative sources is proposed to overcome this issue. First, a maximum likelihood calibration model is established including both the unknown array non-ideal parameters and 2-D DOAs of all calibration sources. Next, the ambiguity of sensor position estimation caused by inaccurate 2-D DOAs of calibration sources is analyzed. Furthermore, a dimension-reduction maximum likelihood calibration model is proposed to resolve the ambiguity under the zero mean Gaussian distribution assumption of the calibration source elevation errors. Then, since the proposed multi-parameter dimension-reduction model is non-convex and multimodal, a new filled function method is proposed to cope with its local extrema attractors. The proposed single-parameter filled function has a single form without an exponential term and is second-order continuously differentiable, which is stable for numerical calculations and easy to optimize by local optimization tools. Finally, the closed-form hybrid Cramer-Rao lower-bound expressions of array parameters under unknown source DOAs are derived in detail. Numerical results verify the effectiveness of the proposed algorithm.
6 June 2025 in IEEE Antennas and Wireless Propagation Letters
The precise mutual coupling model is the key to obtain an accurate parametric analytic manifold, which is the prerequisite to achieve super-resolution direction of arrival estimation and highprecision beamforming. The widely used mutual coupling model is linear and cannot describe the direction-dependent characteristics of mutual coupling, which leads to serious performance deterioration of array signal processing algorithms. In this letter, a new non-linear mutual coupling model named high-order broad mutual coupling matrix (MCM) is established based on the Taylor expansion to describe the directional dependent coupling relationship between two adjacent antenna elements. Then, an accurate parametric analytic manifold using a finite-order approximation of the high-order broad MCM is yield by the antenna pattern reconstruction method. Numerical examples verify that the array manifold reconstruction errors can be reduced exponentially by the proposed parametric analytic manifold. Especially when the piecewise fitting strategy is adopted, the reconstruction errors of the fourth-order approximated analytic manifold can be reduced to less than 1% of those of the conventional array manifold.
8 October 2025 in IEEE Transactions on Antennas and Propagation
The accurate parametric array manifold is the theoretical basis of array signal processing technology. In this paper, a compact parametric model of the true array manifold is proposed. A virtual extended array is established by splitting each antenna into a collection of finite-length dipoles, of which the mutual coupling effect is described using a nonlinear coupling model based on Taylor expansion. The resulting composite manifold has a simple form composed of an expanded virtual isolated manifold and a broad coupling matrix, which can provides an extremely accurate representation of the true array manifold. Numerical examples verify that the accuracy of the proposed composite manifold is two or three orders of magnitude better than that of several other state-of-the-art manifolds. The proposed composite manifold can be applied to all kinds of array signal processing algorithms directly to enhance the capabilities of antenna arrays in practical applications by replacing the overly simplified and imprecise manifold.
1 January 2026 in IEEE Transactions on Antennas and Propagation