Farisse Chirindja

Mr. Farisse Chirindja


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2017 in Hydrogeology Journal
Verified
Journal Article
Open access
PDF file
FCFarisse Chirindja
Farisse Chirindja
TDT. Dahlin
T. Dahlin
DJD. Juizo
D. Juizo
Vertical electrical sounding was used for assessing the suitability of the drill sites in crystalline areas within a water supply project in Nampula Province in Mozambique. Many boreholes have insufficient yield (420 ohm-m) with low porosity and high permeability. In addition to this, there is unfractured nonpermeable intact rock with resistivity of thousands of ohm-m. The unsuccessful boreholes were drilled over a highly resistive zone corresponding to fresh crystalline rock and a narrow altered layer with lower resistivity. Successful boreholes were drilled in places where the upper layers with lower resistivity correspond to a well-developed altered layer or a well-fractured basement. There are a few exceptions with boreholes drilled in seemingly favourable locations but they were nevertheless unsuccessful boreholes for unknown reasons. Furthermore, there were boreholes drilled into very resistive zones that produced successful water wells, which may be due to narrow permeable fracture zones that are not resolved by ERT. Community involvement is proposed, in choosing between alternative borehole locations based on information acquired with a scientifically based approach, including conceptual geological models and ERT. This approach could probably lower the borehole failure rate.

30 December 2016 in Environmental Earth Sciences
Verified
Journal Article
Open access
PDF file
FCFarisse Chirindja
Farisse Chirindja
TDT. Dahlin
T. Dahlin
DJD. Juizo
D. Juizo
FSF. Steinbruch
F. Steinbruch
In continental margin basins, the hydrogeological setting is complex due to transgression/regression events that removed old sediments in the basin and formed new geologic units. Due to the geological complexity, the use of vertical electrical sounding has proven to be insufficient for groundwater explorations. The lack of understanding the geological underground has resulted in many boreholes with low yield or poor water quality. By performing electrical resistivity tomography (ERT) and induced polarization (IP) measurements in 11 villages in Mongicual district, three different layers covering the basement were identified: a weathered autochthon layer, a weathered allochthon layer (paleo-coastal dune) and eolian white sand layer. The drilling at successful boreholes penetrates formations where the resistivity value is between 220 and 770 Ωm, whereas at unsuccessful boreholes the lower parts of the drilled range have resistivity values higher than 770 Ωm. Also, the thickness ratio of the weathered and semi-weathered layer in the unsuccessful boreholes is less than 1/3, whereas in all successful boreholes the ration is higher than 1/2. The difference between autochthon and allochthon layers was detected by heavy minerals content in the red eolian sand layer (Tupuito formation) that increased the chargeability value. The groundwater with a conductivity higher than 2000 µS/cm is linked to the white eolian sand. The surface extension of white eolian sand layer is small to be mapped; therefore, by mapping the eolian white sand formation and the use of ERT and enhanced with IP method would lower the failure rate.

8 February 2017 in Water
Verified
Journal Article
Open access
PDF file
FCFarisse Chirindja
Farisse Chirindja
JRJan-Erik Rosberg
Jan-Erik Rosberg
TDTorleif Dahlin
Torleif Dahlin
In Nampula province, Mozambique, there is a high number of water wells considered as having failed for having too low a pumping yield. Two Electrical Resistivity Tomography (ERT) measurement campaigns were conducted in the area for evaluating the reasons of failures. However, in some cases it was difficult to verify and interpret the ERT results by only using the inadequate lithological description presented in drilling reports. In this paper the integration of borehole logging and slug testing is presented as a solution to add more information and to enhance the interpretation of ERT models. The borehole logging tool measured resistivity, magnetic susceptibility and natural gamma. The logging results proved that the ERT models are accurate in estimating the resistivity for basement (>1400 Ωm), fractured layer (220–1400 Ωm), semi-weathered layer with clay accumulation (10–220 Ωm), and weathered and leached layer (220–2700 Ωm). The slug testing gave results of high hydraulic conductivity (K) values where the ERT indicates well-developed weathered and fractured layers, and low K values where these are less developed. The borehole interpretation can be extrapolated using the ERT model to give a geometric characterization of the aquifer. Therefore, the implementation of the ERT method in groundwater exploration is encouraged.