In recent decades, interest in the resistance of buildings and structures to progressive collapse has been increasingly sparked in research communities. Although several experimental, numerical, and analytical research projects on the robustness of building frames under a column removal scenario have been implemented, some aspects of this problem remain understudied. These aspects encompass failure mechanisms of reinforced concrete frames with slender columns, as well as criteria used to evaluate such failures. This paper focuses on experimental and numerical investigations of the structural behavior and failure of a scale reinforced concrete frame with slender columns under a sudden corner column removal scenario. In addition, we analyze the stability failure mechanism of a reinforced concrete frame with slender columns and the tangent stiffness criterion, which allow for evaluation of the ultimate state of a structure subjected to an accidental impact. A scale physical model of a reinforced concrete frame of a multistory building was designed and tested using the theory of functional similarity. For numerical study purposes, a finite element model was made that exactly the same as the test frame. We validated the findings by comparing simulation results and experimental data. The studies on the behavior of a reinforced concrete frame subjected to quasistatic loading with unequal concentrated loads identified the load transfer between columns through beams. Although these effects were minor in the frame under consideration, they can become more significant in cases of long-term loading. Numerical simulation and physical modeling of an accidental impact allowed for identification of the mechanism of load capacity exhaustion triggered by stability failure. Such failure was fragile. The moment of stability failure of the column of the experimental frame corresponded to the extremum on the force–displacement curve, indicating that zero tangent stiffness was reached. Hence, a criterion of tangent stiffness can be proposed for evaluation of the ultimate state of a structure subjected to an accidental impact.
A possible way to improve the structural safety and robustness of precast building structures is to develop effective precast frame systems with layered beams, which combine prefabricated parts with cast-in situ ordinary concrete, high-performance concrete, fiber concrete, or FRP. The paper provides a new type of precast reinforced concrete frame system with layered beams for rapidly erected multi-story buildings resistant to accidental actions. Using a combination of the variational method and two-level design schemes, a simplified analytical model has been developed for structural analysis of the precast reinforced concrete frame system, both for serviceable and ultimate limit states as well as for accidental actions. The proposed model allows for determining shear deformations and the formation and opening of longitudinal cracks in the intermediate contact zone between precast and monolithic parts of reinforced concrete structural elements of the frame, as well as the formation and opening of normal cracks because of the action of axial tensile force or bending moment in these elements. The design model was validated by comparing the calculated and experimental data obtained from testing scaled models of the precast reinforced concrete frame system with layered beams. The paper investigates and thoroughly analyzes the factors affecting the stiffness and bearing capacity of the intermediate contact zone, discusses the criteria for the formation of shear cracks along the contact zone of precast and monolithic concrete, and examines the change in the stiffness and dissipative properties of layered elements at different stages of their static–dynamic loading. The robustness of the experimental models of the structural system was not ensured under the specified load, section dimensions, and reinforcement scheme. Following an accidental action, longitudinal cracks were observed in the contact joint between the monolithic and prefabricated parts in the layered beams. This occurred almost simultaneously with the opening of normal cracks in adjacent sections. A comprehensive analysis of the results indicated a satisfactory degree of agreement between the proposed semi-analytical model and the test data.
1 January 2015 in Journal of the Serbian Society for Computational Mechanics
In the article the task of cross bending of elastic isotropic plates with simply supported and clamped edge from the action of evenly distributed load is described. It is suggested to use form factor interpolation technique to determine the value of maximum plate deflection; and the ratio of inner conformal radius to the outer as a geometric argument is proposed to be used instead of form factor. Such replacement allows the increase of the technique accuracy.
This study focused on the advanced analysis of the crack resistance of reinforced concrete structures and provides proposals for improvement of the theory of calculation of reinforced concrete structures for serviceability and ultimate limit state. Despite the fact that the crack opening is a key parameter of reinforced concrete structures that frequently determines the reinforcement area, the design models and theory of calculation of this parameter are still not sufficiently perfect. The recent studies performed worldwide with the use of more advanced instrumentation have shown that the accuracy of theoretical prediction of crack opening in structures experiencing a complex stress–strain state, and especially structures made of high-strength concrete, fiber-reinforced concrete, lightweight concrete, and etc., remains unsatisfactory. This study analyzed and summarizes experimental studies of crack resistance of reinforced concrete structures and reveals new physical regularities in the deformation of concrete and steel reinforcement in zones adjacent to the crack. It introduces hypotheses that account for these regularities and proposes a general block model for calculating the width of irregular and single cracks in reinforced concrete structures under different stress states. In this model, crack opening is modeled by the double-cantilever element (DCE), which allows incorporation of the corresponding experimentally revealed effects and at the same time combines deformation parameters of both the theory of reinforced concrete and fracture mechanics. The DCE is two conventionally separated rigid cantilevers that include the crack surfaces, and are embedded on one side in the concrete at the neutral axis. On the other side, they are connected with reinforced steel bars crossing the crack. Using this model, a method for calculating the crack opening width in reinforced concrete structures with different types of cracks is proposed. The paper demonstrates the results of experimental investigations of crack resistance of simply supported and cantilever beams made of ordinary, light, and high-strength concrete. These results confirm the effects considered in the calculation model and the hypotheses accepted in the theory. The study also provides a physical explanation of the phenomena under consideration and shows acceptable agreement between theoretical and experimental values of crack opening calculated according to the proposed theory.
19 April 2021 in Journal of Physics D: Applied Physics
A single wavelength heterodyne interferometer has been set up to investigate the free electron density integrated axially along the line of sight (line density) in a theta-pinch plasma to determine its applicability as a plasma target for ion beam stripping. The maximal line density reached in this experiment was cm−2 at 80 Pa and 20 kV. The findings demonstrate the pulsed character of the line density and its increase by raising the load voltage and the working gas pressure. Additionally, the results were compared with spectroscopic free electron density estimations, which were carried out by H -line broadening and peak separation. The time behavior of the line density indicates that its peak value is delayed by about 10 µs compared to the spectroscopic results. This effect is due to the formation of an extended, magnetically compressed plasma column in the vicinity of the current maximum, although the highest volumetric free electron density is reached near the current zero crossing. Since the line density is an essential parameter in describing the stripping capabilities of the plasma target, the interferometric diagnostic is superior to a spectroscopic diagnostic, because it directly provides integrated values along the line of sight. Furthermore, the measurements of the line density in this experiment partially show nonphysical negative values, which is due to gaseous effects and residual shot vibrations.
1 January 2016 in Journal of the Serbian Society for Computational Mechanics
The article deals with the transverse bending problem of thin elastic orthotropic plates with combined boundary conditions. The form factor interpolation method is used for deformation calculations. Analytical expressions of maximum deflection surfaces are obtained. It is proposed to use these expressions as the reference solutions. The example of the solution to the problem of transverse bending plate in the form of a parallelogram is given.