Gudrun H. Borchert

Dr. Gudrun H. Borchert

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2023 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
CKChristian Krasny
Christian Krasny
CRChristian Radda
Christian Radda
RPRalf Polke
Ralf Polke
DSDaniel Schallmayer
Daniel Schallmayer
GBGudrun H. Borchert
Gudrun H. Borchert
CAChristian Albrecht
Christian Albrecht
Introduction: The prime requisites of a good digital arthrodesis are a painless and stable union in a proper position. Arthrodesis of the distal interphalangeal joint of the fingers is not without potential complications including nonunion, malunion, and deep tissue infections. The Shark Screw® is a human, cortical bone allograft for osteosynthesis and an alternative to metal or bioabsorbable devices in orthopedics and trauma surgery. The primary hypothesis is that the fusion and complication rate, using the Shark Screw®, is at least similar to those reported in the literature, using metal or bioabsorbable screws. Material and methods: This retrospective cohort study analyzes the fusion and complication rate and the patient satisfaction of distal interphalangeal joint arthrodesis of 27 fingers with the human allogeneic cortical bone screw. Complications, Disabilities of Arm, Shoulder, and Hand Questionnaire (Quick-DASH) score and Michigan Hand Outcomes Questionnaire (MHQ) score, grip and pinch strength and fusion angle were investigated. Results: The mean follow-up was 23 months. At 6 weeks after surgery, fusion was obtained for all fingers. There was no surgical complication that required revision surgery. An average fusion angle of 13.6° ± 10.7° was measured. VAS pain score decreased significantly from 6.9 before surgery to 0.14 after surgery. The Quick-DASH score decreased from 10.7 to 7.8. The MHQ score improved in all sub-scores. Conclusion: The complication rates, using the Shark Screw® for DIP joint arthrodesis, are lower compared to the results reported in the literature for other surgical techniques. Complications related to the human allograft cortical bone screw itself were not observed. The bone screw is completely remodeled into the host bone and further hardware removal is not necessary. Level of evidence: IV.

29 July 2022 in Foot & Ankle Orthopaedics
Verified
Journal Article
Open access
BHBeatrice Hanslik-Schnabel
Beatrice Hanslik-Schnabel
DFDaniel Flöry
Daniel Flöry
GBGudrun H. Borchert
Gudrun H. Borchert
JSJakob E. Schanda
Jakob E. Schanda
Background: Different fixation techniques are established for first metatarsophalangeal joint (MTPJ) arthrodesis, including compression screws, plates, Kirschner wires, metal- and bioabsorbable screws as well as staples. The purpose of this study was to investigate and present first clinical and radiologic results using a novel human, allogeneic cortical bone screw for arthrodesis of the first MTPJ. Methods: Arthrodesis of the first MTPJ was performed in 31 patients with hallux rigidus. Percentage union and time to union were the first outcomes; visual analog scale for pain, hallux valgus angle (HVA), intermetatarsal angle, and American Orthopaedic Foot & Ankle Society (AOFAS) hallux score were secondary outcomes. Results: Median time to union was 89 days, and union was observed in all patients. There were 4 complications (2 osteolysis margin, 1 cystic brightening, and 1 severe swelling at the first follow-up) all of that resolved at last follow-up. Pain significantly decreased from visual analog scale 8.0 to 0.2 points ( P < .0001). The HVA decreased from 30.4 to 10.2 degrees in the patient group with deformities. The total AOFAS score increased significantly from 48 to 87 ( P < .0001). Conclusion: Primary and revision arthrodesis of hallux rigidus with the human, allogeneic cortical bone screw reveals satisfying results similar to clinical and radiologic outcomes of other surgical techniques. Within 1 year, the human, allogeneic cortical bone screw is fully remodeled to host bone. Level of Evidence: Level IV, retrospective case series without control group.

15 March 2022 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
RVRichard Volz
Richard Volz
GBGudrun H. Borchert
Gudrun H. Borchert
Background: There is currently no consensus regarding the preferred surgical procedure for the reconstruction of anterior cruciate ligament (ACL). The interference screw technique is widely used, but has been associated with a risk of graft damage. The Press-Fit-Hybrid®-technique is one of the alternatives for biological ACL-reconstruction with minimal implant requirements. The hypothesis of this retrospective analysis is, that the Press-Fit-Hybrid®-technique leads to better results with respect to re-rupture rate and secondary meniscal lesion than the interference-screw-technique. Methods: To compare the re-rupture rate of the interference-screw-technique (IF) used until 2015 with the currently used Press-Fit-Hybrid®-technique (PFH), the last 100 patients of the IF-group and the first 100 patients of the PFH-group were retrospectively analyzed. Primary outcomes were re-rupture rate, complications and secondary meniscal injury. Additionally, laxity, Lachman and Pivot-shift and range of motion were evaluated. Results: A mean follow-up of 4.2 and 5.3 years revealed 4% and 9% re-rupture rates and 1% and 2% complication rates in the PFH- and IF-group, respectively. In the PFH-group there were no re-ruptures in patients older than 23 years. Secondary meniscal injury post-surgery was 6% and 9% for the PFH and IF-group, respectively. Knee stability was similar in both groups. Range of motion was significantly better in the PFH-group, with 136° of flexion, 6 months after surgery. Conclusion: For ACL-reconstruction the Press-Fit-Hybrid®-technique is an alternative new method. Low level of secondary meniscal lesions after surgery and high stability, is known to prevent later arthrosis of the knee. The encouraging observed trend of the reduction of the re-rupture rate in revision surgery and in young patients using the Press-Fit-Hybrid®-technique in comparison to the interference-screw-technique must be confirmed with further studies. Level of evidence: Therapeutic Level III, retrospective cohort study.

17 February 2023 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
MNMirjam Victoria Neumann-Langen
Mirjam Victoria Neumann-Langen
VSVerena Sontheimer
Verena Sontheimer
GBGudrun H. Borchert
Gudrun H. Borchert
Kaywan IzadpanahKaywan Izadpanah
Kaywan Izadpanah
HSHagen Schmal
Hagen Schmal
JKJohanna Kubosch
Johanna Kubosch
Background: Distal femur fractures are challenging in surgical management as the outcome is crucial for restoring the biomechanical stability and longitudinal axis of the leg and function of the knee joint. Methods: A retrospective review of all distal femoral fractures treated in a level I trauma center over a decade was performed. The radiographs were reviewed for fracture entity, osseous healing, implant failure, mechanical axis, and degenerative joint changes. Clinical outcome was reviewed regarding postoperative complications and postoperative range of motion of the knee joint. Results: 130 patients who were managed with screw fixation (n = 35), plating systems (n = 92) or intramedullary nailing systems (n = 3) remained for evaluation. Mean follow up was 26 months. Clinical outcome was significantly better for flexion degrees following screw fixation (p = 0.009). Delayed fracture union (p = 0.002) or non-union (p = 0.006) rates were significantly higher in plate osteosynthesis. Mild pathologic deformity for varus and valgus collapse was found following plate osteosynthesis. Conclusions: Screw fixation shows fewer postoperative complications than plate fixation and is favored for extra and partial intraarticular distal femur fractures. Plating constructs remain the superior fixation method in complex distal femur fractures but are associated with higher rates of non-union and leg axis deviation.

Verified
Journal Article
Open access
PDF file
VLViktor Labmayr
Viktor Labmayr
EHElisabeth Huber
Elisabeth Huber
FWFlorian Wenzel-Schwarz
Florian Wenzel-Schwarz
PHPatrick Holweg Patrick Holweg
Patrick Holweg Patrick Holweg
MOMartin Ornig
Martin Ornig
KPKlaus Pastl
Klaus Pastl
Addressing non-unions involves stabilizing the affected area through osteosynthesis and improving bone biology using bone grafts. However, there is no consensus on the optimal treatment method. This study aims to compare outcomes of non-union surgery using conventional treatment methods (metal hardware ± graft) versus osteosynthesis with the human allogeneic cortical bone screw (Shark Screw®) alone or in combination with a metallic plate. Thirty-four patients underwent conventional treatment, while twenty-eight cases received one or more Shark Screws®. Patient demographics, bone healing, time to bone healing, and complications were assessed. Results revealed a healing rate of 96.4% for the Shark Screw® group, compared to 82.3% for the conventionally treated group. The Shark Screw® group exhibited a tendency for faster bone healing (9.4 ± 3.2 vs. 12.9 ± 8.5 weeks, p = 0.05061). Hardware irritations led to six metal removals in the conventional group versus two in the Shark Screw® group. The Shark Screw® emerges as a promising option for personalized non-union treatment in the foot, ankle, and select lower leg cases, facilitating effective osteosynthesis and grafting within a single construct and promoting high union rates, low complications, and a rapid healing process.

11 July 2022 in Life
Verified
Journal Article
Open access
PDF file
KPKlaus Pastl
Klaus Pastl
EPEva Pastl
Eva Pastl
DFDaniel Flöry
Daniel Flöry
GBGudrun H. Borchert
Gudrun H. Borchert
MCMichel Chraim
Michel Chraim
The case describes the revision of an upper ankle prosthesis because of loosening. When ankle replacement is the first choice and actual bone quality does not allow a replacement of the prosthesis, arthrodesis is the only way of reducing pain and gaining stability. The amount of missing bone due to the removed prosthesis was severe. Shark Screws®, made of human allograft cortical bone, were used to fix an allograft femoral head and tibia as well as fibula and talus to each other for stabilization. This was performed without any autologous bone graft and without metal screws. The human matrix of the cortical allograft allows the creation of new vessels followed by osteoblastic activity and production of new bone. The revascularization of the allografts reduces the risk of infection and wound problems. Over time, the patient’s bone metabolism allows the allografts to be remodeled into the patient’s bone. The case reported here had severe multimorbidity. The loosening of the prosthesis mainly affected the ability to perform housework, mobility, enjoying leisure, and it had a great impact on the emotion and well-being of the patient. One year after surgery, the patient is very satisfied to be able to walk without pain and scratches for about 90 min.