This dataset was compiled to estimate the levels of thermal comfort and mental health in a sample group of university students confined due to the COVID-19 pandemic. By the time research was carried out, these students of a hot and humid region of Mexico, had already spent 200 days on distance learning using online platforms. A total of 324 records were documented with a final sample of 316 valid participants. The total records were collected directly from the students through a web platform (Microsoft forms). This data set can be used to generate correlations between mental health, thermal comfort, and individual characteristics in the study population that will allow to identify the influence of the built environment and local climate on the levels of stress and anxiety that university students experienced under confinement. It can also be used to issue recommendations to improve the quality of built spaces and for the construction of adaptive models of thermal comfort considering mental health as a study variable.
Thermal comfort has become an important element in the design, construction, and remodeling of buildings, as well as in the understanding of human behavior that considers inhabitants’ mental conditions. The objective of this study is to propose general thermal comfort equations via a rigorous statistical evaluation for regions with hot-humid (HH) and hot-dry (HD) climates. From the information on thermal comfort provided in the specialized literature, 17 equations were gathered for hot-humid climates and nine equations for hot-dry climates. These equations were developed for hot climate conditions in zones where buildings operate with natural ventilation (NV). The statistical analysis includes the normality test of the data distribution, the recognition of outliers, and the applications of significance tests for the comparison of the equation parameters. The equations proposed in this paper can be used to initially evaluate the thermal comfort of buildings in locations where no equations have been developed locally, as well as in the energy evaluations of buildings. The equation proposed in this paper for the hot-humid climate is the following: Tc = 16.9 (±2.19) + 0.37 (±0.08) Tout; that for the hot-dry climate is: Tc = 12.9 (±5.36) + 0.56 (±0.20) Tout. These equations can be used to initially assess the thermal comfort of buildings in locations without locally developed equations, as well as in building energy assessments.
The objective of this study was to evaluate the thermal effectiveness of a prototype air-to-water heat exchanger. The system was installed in a shallow aquifer in a coastal region, characterized by a sandy medium with a documented groundwater flow velocity of 0.19 ± 0.01 m/s, operating under a hot and humid climate. The AWHE, constructed (horizontal type), has 11 m of straight sections of polyvinyl chloride (PVC) pipe. The thermohydraulic aspects of the heat exchanger were evaluated using the Number of Heat Transfer Units-Effectiveness (NTU-ε) method. The results of this study show that the temperature of the air circulating through the exchanger was reduced by between 3.02 and 7.94 °C, values higher than those obtained in similar studies with Earth-to-Air Heat Exchangers. However, the analysis is limited to short-term thermohydraulic performance in steady state. Future research is required to validate long-term performance values and the system's response to seasonal changes in aquifer temperature. High values were achieved the temperature drop per unit length in the present prototype is 1.03 °C/m, resulting in thermal effectiveness ranging from 87 to 96%. Both parameters are higher than those reported in recent international studies.