This research presents a comprehensive bibliographic review from 2006 through 2020 about the state of the art of the compression–absorption cascade systems for refrigeration. In consequence of this review, this research identifies the significant development of systems that consider lithium bromide as a working fluid; however, the use of other working fluids has not been developed. This study is motivated toward the development of a parametric analysis of the cascade system using NH3-LiNO3, NH3-NaSCN and NH3-H2O in the absorption cycle and R134a in the compression cycle. In this study, the effect of the heat source temperature, condensation temperature in the compression cycle, the use of heat exchangers in the system (also known as economizers) and their contribution to the coefficient of performance is deepened numerically. The economizers evaluated are the following: an internal heat exchanger, a refrigerant heat exchanger, a solution refrigerant heat exchanger, and a solution heat exchanger. Mass and energy balance equations—appropriate equations to estimate the thermophysical properties of several refrigerant–absorbent pairs—were used to develop a thermodynamic model. The studied heat source temperature range was from 355 to 380 K, and the studied condensation temperature range in the compression cycle was from 281 to –291 K; additionally, the importance of each economizer on the coefficient of performance was numerically estimated. In this way, NH3-NaSCN solution in the absorption cycle and R134a in the compression cycle provided promising numerical results with the highest COPs (coefficient of performance).
1 September 2023 in Results in Control and Optimization
One of the most critical parameters for the capture of solar radiation is the angle of inclination of the surface and its contribution to optimization to maximize the amount of solar irradiation received. Numerous methods have been used worldwide to determine the angle of inclination. Unfortunately, many of these models are for fixed angles, which do not adapt to the sun's position during the year, resulting in the loss of essential amounts of irradiation that could be used. This work presents the methodology for developing a structure for photovoltaic (PV) panels fixed to the floor, which includes variations in the angle of inclination. The goal is to maximize the solar energy gain (energy per square meter) the panel receives over a year by making monthly tilt angle adjustments. The inclination angles are calculated for a structure, which will be placed in Coatzacoalcos, Veracruz, Mexico. The monthly angle of the prototype can have positive and negative values (tropical region); the maximum is 41.19° for December, and the minimum is - 4.95°, corresponding to June. The study can be applied to build a similar structure, with related variations in the angle of inclination, to work in any city, as long as information from the city in question is
31 December 2020 in Revista del Desarrollo Tecnologico
This paper presents the study of a simple effect absorption refrigeration system (SRA) using the ammonia-water working couple, with the incorporation of three economizers and their analysis of the first and second law of thermodynamics, emphasizing the effect of the operating temperatures and the efficiency of the exchangers on the refrigerant circulation ratio (RC), the coefficient of performance (COP) of the system and the destruction of exergy. In order to determine the thermodynamic properties at each point of the system and evaluate the performance of the SRA, was programmed a tool in MATLAB with the governing equations. The results show that: the exergy efficiency increases when the temperature in the evaporator decreases; and RC decreases with increasing temperature in the generator. As conclusion, an increase in the effectiveness of heat exchangers cannot only decrease the refrigerant circulation rate, but also increase the inlet temperature of the solution to the generator, so that the temperature difference between the solution and the heat source decreases, causing a decrease in the rate of exergy destruction in the generator and the increase in COP.
The objective of this study was to evaluate the thermal effectiveness of a prototype air-to-water heat exchanger. The system was installed in a shallow aquifer in a coastal region, characterized by a sandy medium with a documented groundwater flow velocity of 0.19 ± 0.01 m/s, operating under a hot and humid climate. The AWHE, constructed (horizontal type), has 11 m of straight sections of polyvinyl chloride (PVC) pipe. The thermohydraulic aspects of the heat exchanger were evaluated using the Number of Heat Transfer Units-Effectiveness (NTU-ε) method. The results of this study show that the temperature of the air circulating through the exchanger was reduced by between 3.02 and 7.94 °C, values higher than those obtained in similar studies with Earth-to-Air Heat Exchangers. However, the analysis is limited to short-term thermohydraulic performance in steady state. Future research is required to validate long-term performance values and the system's response to seasonal changes in aquifer temperature. High values were achieved the temperature drop per unit length in the present prototype is 1.03 °C/m, resulting in thermal effectiveness ranging from 87 to 96%. Both parameters are higher than those reported in recent international studies.