Alaa Farah Mahmoud Ali

Dr. Alaa Farah Mahmoud Ali


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2022 in Inventions
Verified
Journal Article
Open access
PDF file
Mahmoud Mahrous Amery ArefMahmoud Mahrous Amery Aref
Mahmoud Mahrous Amery Aref
Mahmoud A.MossaMahmoud A.Mossa
Mahmoud A.Mossa
NLNgo Kim Lan
Ngo Kim Lan
NQNguyen Quynh
Nguyen Quynh
VOVladislav Oboskalov
Vladislav Oboskalov
AAAlaa Farah Mahmoud Ali
Alaa Farah Mahmoud Ali
The contribution current of an inverter-interfaced distributed generator unit during a fault is one of the significant challenges for two modes: grid-connected and isolated AC microgrid. For this challenge, this article is aimed to study two methods of fault current calculation for two modes: grid-connected and isolated microgrids. These methods include a virtual equivalent impedance and a proposed method. The proposed method is a new technique for calculating the fault current contribution depending on the droop control of inverter-interfaced DG. The proposed method can control the contribution short-circuit current of DG within its limit (2 p.u.) where it is dependent on the voltage value of the DG bus to calculate the short circuit current of DG by using the control criterion. Static security risk and load shedding are calculated after fault clearance using an operation scenario in which the distribution system will be divided into small subsystems and is then grid-connected and isolated due to the removal of the faulted bus by protection devices. The proposed technique is applied to a standard IEEE 33-bus distribution network with five DGs. The results show that the contribution current of inverter-interfaced DG during the fault has more effects than the fault current of the nearest faulted bus to the DG bus. The proposed technique improves the calculated fault current value by about 30% for the grid-connected microgrid and by about 50% for the isolated microgrid from its value of the virtual impedance method. The static security risk is improved after load shedding. The static security risk improved by about 0.025%.

1 December 2023 in SVU-International Journal of Engineering Sciences and Applications
Verified
Journal Article
Open access
PDF file
AAAlaa Farah Mahmoud Ali
Alaa Farah Mahmoud Ali
OSOla Mostafa A. Saleh
Ola Mostafa A. Saleh
AMAsharf Nasr El-Deen Mourad
Asharf Nasr El-Deen Mourad
Hamdy A. ZiedanHamdy A. Ziedan
Hamdy A. Ziedan
EAEssam Ali
Essam Ali
This paper will review, analyze, model, and check experimentally the most effective techniques of photovoltaic (PV) cooling and control of its temperature in general. This will be analyzed and discussed to choose the suitable methods for Middle East Countries, especially Egypt. Namely, it is well known that an increase in electrical efficiency is a direct result of any decrease in the panel temperature. Several cooling techniques will be studied, analyzed, modelled, and check experimentally the best based on active, passive water and air cooling, as these are the simplest techniques. Improving electrical efficiency depends mainly on the technique used in cooling, geographical position, type and size of the module, and the month or season of the year. Usually, the overall efficiency records improvement with a rise of 10-15 %. Finally, a comparison on deferent cooling techniques for PV panels will be made to discuss which type is suitable for Egypt.

16 January 2026 in Energies
Verified
Journal Article
Open access
PDF file
MSMohamed Sayed
Mohamed Sayed
MNMohamed AbdelAzim Ibrahim Nayel
Mohamed AbdelAzim Ibrahim Nayel
Mohamed AbdelrahemMohamed Abdelrahem
Mohamed Abdelrahem
AAAlaa Farah Mahmoud Ali
Alaa Farah Mahmoud Ali
This paper analyzes the functional feasibility and strategic value of hybrid hydrogen storage and photovoltaic (PV) energy systems at isolated areas, specifically at Egypt’s Shalateen station. The paper is significant as it formulates a solution to the energy independence coupled with economic feasibility issue in regions where the basic energy infrastructure is non-existent or limited. Through the integration of a portfolio of advanced optimization algorithms—Differential Evolution (DE), Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Grey Wolf Optimizer (GWO), Multi-Objective Genetic Algorithm (MOGA), Pattern Search, Sequential Quadratic Programming (SQP), and Simulated Annealing—the paper evaluates the performance of two scenarios. The first evaluates the PV system in the absence of hydrogen production to demonstrate how system parameters are optimized by Pattern Search and PSO to achieve a minimum Cost of Energy (COE) of 0.544 USD/kWh. The second extends the system to include hydrogen production, which becomes important to ensure energy continuity during solar irradiation-free months like those during winter months. In this scenario, the same methods of optimization enhance the COE to 0.317 USD/kWh, signifying the economic value of integrating hydrogen storage. The findings underscore the central role played by hybrid renewable energy systems in ensuring high resilience and sustainability of supplies in far-flung districts, where continued enhancement by means of optimization is needed to realize maximum environmental and technological gains. The paper offers a futuristic model towards sustainable, dependable energy solutions key to the energy independence of the future in such challenging environments.