Factors that cause nonuniformity in the luminescence lifetime of pressure-sensitive paints (PSPs) were investigated. The lifetime imaging method of PSP does not theoretically require wind-off reference images. Therefore, it can improve measurement accuracy because it can eliminate errors caused by the deformation or movement of the model during the measurement. However, it is reported that the luminescence lifetime of PSP is not uniform on the model, even under uniform conditions of pressure and temperature. Therefore, reference images are used to compensate for the nonuniformity of the luminescence lifetime, which significantly diminishes the advantages of the lifetime imaging method. In particular, fast-responding PSPs show considerable variation in luminescence lifetime compared to conventional polymer-based PSPs. Therefore, this study investigated and discussed the factors causing the nonuniformity of the luminescence lifetime, such as the luminophore solvent, luminophore concentrations, binder thickness, and spraying conditions. The results obtained suggest that the nonuniformity of the luminophore distribution in the binder caused by the various factors mentioned above during the coating process is closely related to the nonuniformity of the luminescence lifetime. For example, when the thickness of the binder became thinner than 8 μm, the fast-responding PSPs showed a tendency to vary significantly in the luminescence lifetime. In addition, it was found that the luminescence lifetime of fast-responding PSP could be changed in the depth direction of the binder depending on the coating conditions. Therefore, it is important to distribute the luminophore uniformly in the binder layer to create PSPs with a more uniform luminescence lifetime distribution.
29 September 2023 in Measurement Science and Technology
Lifetime-based pressure- and temperature-sensitive paint (PSP and TSP) measurements were conducted in a large-scale industrial transonic wind tunnel to obtain high-quality pressure data for validation of computational fluid dynamics (CFD) simulations. A wind tunnel test was performed using the NASA common research model in the JAXA 2 m × 2 m transonic wind tunnel. The freestream Mach number was varied in the range of 0.70–0.89, and aerodynamic forces and moments were acquired in order to obtain the pitch break condition related to the onset of shock-induced separation. Polymer-based PSP was coated on a main wing of the model, and TSP was used in tandem with PSP to correct the temperature dependence of PSP. The two-gate lifetime-based method was applied to obtain the PSP and TSP emissions. An a-priori/in-situ hybrid calibration was conducted to convert ratio-of-ratios to pressure, and measured pressure distributions were mapped onto a three-dimensional (3D) model grid. The root-mean-square error for the pressure measurements was evaluated by pressure tap data and was approximated to be 0.8 kPa for all Mach numbers tested. The obtained pressure distributions exhibited a significantly high signal-to-noise ratio and were used for comparison with CFD results on a 3D grid. The high-spatial-resolution PSP measurements helped to accurately localize the differences from the CFD simulation results and showed that the prediction of the shock location along the main wing is still a relevant challenge.
A temperature-sensitive paint (TSP) using a chameleon luminophore is proposed. The chameleon luminophore was dispersed in isobutyl methacrylate polymer in a toluene solvent to fix it on a sample coupon. Temperature and pressure sensitivities of the chameleon luminophore-based TSP were measured using a spectrofluorophotometer. The emission for each wavelength was confirmed to be dependent on the temperature and pressure. The temperature and pressure sensitivities of the TSP were 0.81–2.8%/K and 0.08–0.12%/kPa, respectively. Higher temperature sensitivity can be obtained using the ratio of emissions from the two lanthanide ions, and . The temperature sensitivity when using the ratio of the emission intensities at 616 nm derived from and at 545 nm derived from was 3.2%/K, which was the highest value in the present study. In addition, the pressure sensitivity for the case using the ratio of the emission intensities at 616 and 545 nm was /kPa. Higher temperature sensitivity and lower pressure sensitivity than that with a single wavelength can be achieved using the ratio of the emission intensities at the two peak wavelengths derived from and .