Jieyuan Yang

Prof. Dr. Jieyuan Yang

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
JYJieyuan Yang
Jieyuan Yang
HYHao Yuan
Hao Yuan
YJYang Jieyuan
Yang Jieyuan
RZRuilin Zhu
Ruilin Zhu
There are many factors influencing the energy consumption of buildings in complex working conditions. In order to study the factors influencing the energy consumption of residential buildings with nearly zero energy in cold and arid regions of northwest China, factors such as the roof heat transfer coefficient (KR), exterior wall heat transfer coefficient (KE), ground heat transfer coefficient (KG), exterior window heat transfer coefficient (KEW), north window wall ratio (WWRN), south window wall ratio (WWRS), east west window wall ratio (WWRWE), building orientation (BO), and ventilation times (VT) are taken as the influencing factors in this paper. Using the orthogonal test, 135 building energy consumption calculation models were built in DeST, and the influence of 9 factors on building energy consumption in 5 types of regions (severe cold region A (1A), severe cold region B (1B), severe cold region C (1C), cold region A (2A), and cold region B (2B)) were analyzed. The conclusions are as follows: in the process of realizing nearly zero energy of residential buildings in the cold and arid regions of northwest China, the KR, KE, KG, KEW, WWRN, WWEWE should be reduced as much as possible in the five regions. The 1A,1B,1C regions should increase WWEWE and VT, with BO of about 15° east of due north and VT of about 5, 8, and 10 times per hour, respectively. The WWES, BO and VT for the 2A region should be set at round 0.45, north-south, and about 10 times per hour, respectively. For the 2B region, WWES should be set at around 0.45, BO around 15° east of due north, and VT as low as possible within the scope of the ‘technical standard for nearly zero energy buildings’.

31 August 2026 in Energies
Verified
Journal Article
Open access
PDF file
ZCZongli Chai
Zongli Chai
JYJieyuan Yang
Jieyuan Yang
Forecast errors in direct normal irradiance (DNI) and load demand can reduce the economic performance of concentrated solar power (CSP) plants with thermal energy storage (TES). This study compares a day-ahead-only strategy (DA-only), rolling particle swarm optimization (DA + RollPSO), and model predictive control (DA + MPC) in a common CSP-TES-grid framework. The analysis covers 12 independent monthly representative 24 h cases with synthetically generated DNI and load forecast errors. All strategies use the same day-ahead baseline, system parameters, physical constraints, and error realizations. Relative to DA-only, DA + RollPSO reduced total operating cost and grid purchases by 1.48% and 1.40%, while DA + MPC achieved reductions of 1.47% and 1.37%. The archived post-correction main comparison used tracking-augmented objectives for both intraday methods with identical normalized weights. DA + RollPSO achieved a TES stored-energy RMSE of 16.22 MWhth, whereas DA + MPC produced 18.09 MWhth with a shorter repeated mean single-step solution time (3.219 versus 43.850 ms). Both intraday strategies also reduced cost relative to DA-only in all 20 documented paired Monte Carlo trials. These results indicate a case-specific trade-off between TES trajectory tracking and computational burden, not universal superiority of either controller.