An electrical power system (EPS) is subject to unexpected events that might cause the outage of elements such as transformers, generators, and transmission lines. For this reason, the EPS should be able to withstand the failure of one of these elements without changing its operational characteristics; this operativity functionality is called contingency. This paper proposes a methodology for the optimal location and sizing of a parallel static Var compensator (SVC) in an EPS to reestablish the stability conditions of the system before contingencies take place. The system’s stability is analyzed using the fast voltage stability index (FVSI) criterion, and the optimal SVC is determined by also considering the lowest possible cost. This research considers contingencies involving the disconnection of transmission lines. Then, the methodology analyzes every scenario in which a transmission line is disconnected. For every one of them, the algorithm finds the weakest transmission line by comparing FVSI values (the higher the FVSI, the closer the transmission line is to instability); afterward, when the weakest line is selected, by brute force, an SVC with values of 5 Mvar to 100 Mvars in steps of 5 Mvar is applied to the sending bus bar of this transmission line. Then, the SVC value capable of reestablishing each line’s FVSI to its pre-contingency value while also reestablishing each bus-bar’s voltage profile and having the lowest cost is selected as the optimal solution. The proposed methodology was tested on IEEE 14, 30, and 118 bus bars as case studies and was capable of reestablishing the FVSI in each contingency to its value prior to the outage, which indicates that the algorithm performs with 100% accuracy. Additionally, voltage profiles were also reestablished to their pre-contingency values, and in some cases, they were even higher than the original values. Finally, these results were achieved with a single solution for a unique SVC located in one bus bar that is capable of reestablishing operational conditions under all possible contingency scenarios.
This research proposes a methodology for the optimal location and sizing of reactive compensation in an electrical transmission system through a deep neural network (DNN) by considering the smallest cost for compensation. An electrical power system (EPS) is subjected to unexpected increases in loads which are physically translated as an increment of users in the EPS. This phenomenon decreases voltage profiles in the whole system which also decreases the EPS’s reliability. One strategy to face this problem is reactive compensation; however, finding the optimal location and sizing of this compensation is not an easy task. Different algorithms and techniques such as genetic algorithms and non-linear programming have been used to find an optimal solution for this problem; however, these techniques generally need big processing power and the processing time is usually considerable. That being stated, this paper’s methodology aims to improve the voltage profile in the whole transmission system under scenarios in which a PQ load is randomly connected to any busbar of the system. The optimal location of sizing of reactive compensation will be found through a DNN which is capable of a relatively small processing time. The methodology is tested in three case studies, IEEE 14, 30 and 118 busbar transmission systems. In each of these systems, a brute force algorithm (BFA) is implemented by connecting a PQ load composed of 80% active power and 20% reactive power (which varies from 1 MW to 100 MW) to every busbar, for each scenario, reactive compensation (which varies from 10 Mvar to 300 Mvar) is connected to every busbar. Then power flows are generated for each case and by selecting the scenario which is closest to 90% of the original voltage profiles, the optimal scenario is selected and overcompensation (which would increase cost) is avoided. Through the BFA, the DNN is trained by selecting 70% of the generated data as training data and the other 30% is used as test data. Finally, the DNN is capable of achieving a 100% accuracy for location (in all three case studies when compared with BFA) and objective deviation has a difference of 3.18%, 7.43% and 0% for the IEEE 14, 30 and 118 busbar systems, respectively (when compared with the BFA). With this methodology, it is possible to find the optimal location and sizing of reactive compensation for any transmission system under any PQ load increment, with almost no processing time (with the DNN trained, the algorithm takes seconds to find the optimal solution).
This study presents a systematic bibliometric review of digital innovations in renewable energy-oriented power systems, with a focus on Blockchain, Artificial Intelligence (AI), the Internet of Things (IoT), and Data Analytics. The objective is to evaluate the research landscape, trends, and integration potential of these technologies within sustainable energy infrastructures. Peer-reviewed journal articles published between 2020 and 2025 were retrieved from Scopus using a structured search strategy. A total of 23,074 records were initially identified and filtered according to inclusion criteria based on relevance, peer-review status, and citation impact. No risk of bias assessment was applicable due to the nature of the study. The analysis employed bibliometric and keyword clustering techniques using VOSviewer and MATLAB to identify publication trends, citation patterns, and technology-specific application areas. AI emerged as the most studied domain, peaking with 1209 papers and 15,667 citations in 2024. IoT and Data Analytics followed in relevance, contributing to real-time system optimization and monitoring. Blockchain, while less frequent, is gaining traction in secure decentralized energy markets. Limitations include possible indexing delays affecting 2025 trends and the exclusion of gray literature. This study offers actionable insights for researchers and policymakers by identifying converging research fronts and recommending areas for regulatory, infrastructural, and collaborative focus. This review was not pre-registered. Funding was provided by the Universidad Politécnica Salesiana under project code 005-01-2025-02-07.
The present investigation proposes a methodology for the optimal location of reactive compensation in an electrical power system (EPS) through deep neural networks for voltage profile improvement. One of the main parameters to consider regarding EPS reliability is the voltage profile, a parameter that can be affected due to unexpected increases in impedance and loads in the system that translate as overloads in the system and an increase in the number of users. A voltage profile below the minimum or above the maximum accepted in the regulations of each country puts at risk the correct operation of equipment connected to the electrical network and, in turn, can cause economic losses and human lives (e.g by not guaranteeing reliability for hospitals and similar institutions).
This paper addresses the challenge of restoring electrical service in distribution systems (DS) under contingency scenarios using a genetic algorithm (GA) implemented in MATLAB. The proposed methodology seeks to maximize restored load, considering operational constraints such as line loadability, voltage limits, and radial topology preservation. It is evaluated with simulations on the IEEE 34-bus test system under four contingency scenarios that consider the disconnection of specific branches. The algorithm’s ability to restore service is demonstrated by identifying optimal auxiliary line reconnections. The method maximizes restored load, achieving between 97% and 99% load reconnection, with an average of 98.8% across the four cases analyzed. Bus voltages remain above 0.95 pu and below the upper limit. Furthermore, test feeder results demonstrate that line loadability is mostly below 60% of the post-reconfiguration loadability.
This study focuses on the challenge of short-term economic dispatch in hybrid generation systems, specifically under scenarios where energy constraints arise due to reduced water availability. The primary aim is to compare various generation scenarios to evaluate the influence of renewable energy-based power plants on the overall operating cost of an Electric Power System. The hybrid generation system under analysis comprises hydroelectric, thermoelectric, photovoltaic solar, and wind power plants. The latter two, in particular, play a crucial role, yet their performance is highly dependent on the variability of their primary resources—solar radiation, wind speed, and ambient temperature—which are inherently stochastic. To estimate their behavior, the Monte Carlo method is applied, utilizing probability distribution functions to predict resource availability throughout the planning horizon. Once the scenarios are established, the problem is formulated as a hydrothermal dispatch optimization, which is then tackled using heuristic and metaheuristic approaches, with a strong focus on the Differential Evolution algorithm.