Luis Fernando Tipan

Prof. Luis Fernando Tipan

Electrical Engineering, Universidad Politécnica Salesiana, Quito, Pichincha, Ecuador
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
Manuel JaramilloManuel Jaramillo
Manuel Jaramillo
Diego CarriónDiego Carrión
Diego Carrión
Jorge Paul MuñozJorge Paul Muñoz
Jorge Paul Muñoz
Luis Fernando TipanLuis Fernando Tipan
Luis Fernando Tipan
This study presents a systematic bibliometric review of digital innovations in renewable energy-oriented power systems, with a focus on Blockchain, Artificial Intelligence (AI), the Internet of Things (IoT), and Data Analytics. The objective is to evaluate the research landscape, trends, and integration potential of these technologies within sustainable energy infrastructures. Peer-reviewed journal articles published between 2020 and 2025 were retrieved from Scopus using a structured search strategy. A total of 23,074 records were initially identified and filtered according to inclusion criteria based on relevance, peer-review status, and citation impact. No risk of bias assessment was applicable due to the nature of the study. The analysis employed bibliometric and keyword clustering techniques using VOSviewer and MATLAB to identify publication trends, citation patterns, and technology-specific application areas. AI emerged as the most studied domain, peaking with 1209 papers and 15,667 citations in 2024. IoT and Data Analytics followed in relevance, contributing to real-time system optimization and monitoring. Blockchain, while less frequent, is gaining traction in secure decentralized energy markets. Limitations include possible indexing delays affecting 2025 trends and the exclusion of gray literature. This study offers actionable insights for researchers and policymakers by identifying converging research fronts and recommending areas for regulatory, infrastructural, and collaborative focus. This review was not pre-registered. Funding was provided by the Universidad Politécnica Salesiana under project code 005-01-2025-02-07.

18 October 2022 in Heliyon
Verified
Journal Article
Open access
Manuel JaramilloManuel Jaramillo
Manuel Jaramillo
Luis Fernando TipanLuis Fernando Tipan
Luis Fernando Tipan
Jorge Paul MuñozJorge Paul Muñoz
Jorge Paul Muñoz
The present investigation proposes a methodology for the optimal location of reactive compensation in an electrical power system (EPS) through deep neural networks for voltage profile improvement. One of the main parameters to consider regarding EPS reliability is the voltage profile, a parameter that can be affected due to unexpected increases in impedance and loads in the system that translate as overloads in the system and an increase in the number of users. A voltage profile below the minimum or above the maximum accepted in the regulations of each country puts at risk the correct operation of equipment connected to the electrical network and, in turn, can cause economic losses and human lives (e.g by not guaranteeing reliability for hospitals and similar institutions).

17 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
DCDavid Alejandro Calvachi
David Alejandro Calvachi
Luis Fernando TipanLuis Fernando Tipan
Luis Fernando Tipan
Manuel JaramilloManuel Jaramillo
Manuel Jaramillo
The approach proposed for the development of this research work was based on the integration of Distributed Energy Generation (DG) into an energy distribution network, improving the voltage profile by establishing an optimal location and sizing of DG power plants, for which the use of a heuristic optimization method known as Genetic Algorithm (GA), which has several restrictions to limit its operation and thus achieve an optimal solution to the planned optimization problem, was resorted to. The development of a power flow allowed having the voltage measurement in the bars of the network before incorporating DG, allowing to verify that the voltage fluctuations present an improvement after the incorporation one by one of each DG central defined by the GA. The systems in which the voltage measurement was performed, as well as the verification of its fluctuations with and without DG once the GA was used, were the IEEE systems of 9 and 14 busbars, the latter the one used to demonstrate the scalability of the GA to locate and dimension DG without considering the number of busbars in a system.

30 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
Jorge Paul MuñozJorge Paul Muñoz
Jorge Paul Muñoz
Luis Fernando TipanLuis Fernando Tipan
Luis Fernando Tipan
Cristian CujiCristian Cuji
Cristian Cuji
Manuel JaramilloManuel Jaramillo
Manuel Jaramillo
This paper addresses the challenge of restoring electrical service in distribution systems (DS) under contingency scenarios using a genetic algorithm (GA) implemented in MATLAB. The proposed methodology seeks to maximize restored load, considering operational constraints such as line loadability, voltage limits, and radial topology preservation. It is evaluated with simulations on the IEEE 34-bus test system under four contingency scenarios that consider the disconnection of specific branches. The algorithm’s ability to restore service is demonstrated by identifying optimal auxiliary line reconnections. The method maximizes restored load, achieving between 97% and 99% load reconnection, with an average of 98.8% across the four cases analyzed. Bus voltages remain above 0.95 pu and below the upper limit. Furthermore, test feeder results demonstrate that line loadability is mostly below 60% of the post-reconfiguration loadability.

10 May 2024 in Energies
Verified
Journal Article
Open access
PDF file
RCRoger David De la Cruz
Roger David De la Cruz
Luis Fernando TipanLuis Fernando Tipan
Luis Fernando Tipan
Cristian CujiCristian Cuji
Cristian Cuji
This research focuses on evaluating the importance of the use of renewable sources through distributed generation and its implication in the operation of electrical systems given that its incorporation has a direct impact on the expansion of the capacity of the networks, the minimization losses, and the impact on end users, all supported by the growth of demand. Under this context, the study focuses on incorporating distributed generation (DG), taking scenarios of base, medium, and peak demand and the modeling of the network, and subsequently evaluating the service quality indices and operating costs in addition to the electrical variables of the system. For this purpose, the present work proposes an optimization model to be solved using the Matlab (2021b) computational program together with GAMS (37.1.0 Major release (11 November 2021)) and mixed-integer nonlinear programming, determining the optimal insertion and determination of the maximum capacity of distributed generators while complying with the technical restrictions of the system and applying optimal AC power flows. Localizing and determining maximum capacity for distributed generation (DG) in electrical systems are critical aspects of modern grid planning and operation. With the increasing penetration of renewable energy sources and the growing complexity of energy demand patterns, efficient integration of DG has become paramount for ensuring grid reliability and sustainability. In this context, the analysis of DG localization and capacity determination considering demand scenarios emerges as a critical area of research in electrical engineering. By employing advanced optimization techniques such as mixed-integer nonlinear programming (MINP), this research addresses the multidimensional challenges associated with DG deployment, including technical constraints, economic considerations, and environmental impacts. Understanding the contribution of this optimization approach to electrical engineering is fundamental for optimizing grid performance, enhancing renewable energy integration, and supporting the transition towards more resilient and sustainable energy systems. Consequently, investigating this optimization model represents a crucial step towards advancing the state-of-the-art in grid planning and facilitating the transition to a cleaner and more efficient energy future.

11 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
Manuel JaramilloManuel Jaramillo
Manuel Jaramillo
Diego CarriónDiego Carrión
Diego Carrión
FPFilippos Perdikos
Filippos Perdikos
Luis Fernando TipanLuis Fernando Tipan
Luis Fernando Tipan
This research presents a novel methodology based on data analysis for improving voltage stability in transmission systems. The proposal aims to determine a single distributed generator’s optimal location and sizing using the Fast Voltage Stability Index (FVSI) as the primary metric under N−1 contingency conditions. The developed strategy systematically identifies the most critical transmission lines close to instability through a frequency analysis of the FVSI in the base case and across multiple contingency scenarios. Subsequently, the weak buses associated with the most critical line are determined, on which critical load increases are simulated. The Distributed Generator (DG) sizing and location parameters are then optimized through a statistical analysis of the inflection point and the rate of change of the FVSI statistical parameters. The methodology is validated in three case studies: IEEE systems with 14, 30, and 118 buses, demonstrating its scalability and effectiveness. The results show significant reductions in FVSI values and notable improvements in voltage profiles under stress and contingency conditions. For example, in the 30-bus IEEE system, the average FVSI for all contingency scenarios was reduced by 26% after applying the optimal solution. At the same time, the voltage profiles even exceeded those of the base case. This strategy represents a significant contribution, as it is capable of improving the stability of the electrical power system in all N−1 contingency scenarios with overload at critical nodes. Using a single DG as a low-cost and highly effective corrective measure, the proposed approach outperforms conventional solutions through statistical analysis and a data-centric approach.