Background: Scapular notching following reverse shoulder arthroplasty (RSA) is caused by both biological and mechanical mechanisms. Some authors postulated that osteolysis that extends over the inferior screw is caused mainly by biological notching. Inverted-bearing RSA (IB-RSA) is characterized by a polyethylene glenosphere and a metallic humeral liner, decreasing the poly debris formation and potentially reducing high grades of notching. This study aims to report the results of IB-RSA on a consecutive series of patients at mid-term follow-up, focusing on the incidence of Sirveaux grade 3 and 4 scapular notching. Methods: A retrospective study on 78 consecutive patients who underwent primary IB-RSA between 2015–2017 was performed. At a 4 years minimum follow-up, 49 patients were evaluated clinically with Constant score (CS), Subjective shoulder value (SSV), American Shoulder and Elbow score (ASES), pain and range of motion, and with an X-ray assessing baseplate position (high, low), implant loosening, and scapular notching. Results: At a mean follow-up of 5.0 ± 0.9, all the clinical parameters improved (p < 0.05). One patient was revised for an infection and was excluded from the evaluation, two patients had an acromial fracture, and one had an axillary neuropraxia. Scapular notching was present in 13 (27%) patients (six grade 1, seven grade 2) and no cases of grade 3 and 4 were observed. Scapular nothing was significantly associated with high glenoid position (p < 0.001) and with lower CS (70 ± 15 vs. 58 ± 20; p = 0.046), SSV (81 ± 14 vs. 68 ± 20; p = 0.027), ASES (86 ± 14 vs. 70 ± 22; p = 0.031), and anterior elevation (148 ± 23 vs. 115 ± 37; p = 0.006). A 44 mm- compared to 40 mm-glenosphere was associate with better CS (63 ± 17 vs. 78 ± 11; p = 0.006), external (23 ± 17 vs. 36 ± 17; p = 0.036), and internal rotation (4.8 ± 2.7 vs. 7.8 ± 2.2; p = 0.011). Conclusions: IB-RSA is a safe and effective procedure for mid-term follow-up. Inverting biomaterials leads to a distinct kind of notching with mainly mechanical features. Scapular notching is associated with a high baseplate position and has a negative influence on range of motion and clinical outcome.
Background: A Critical Shoulder Angle (CSA), evaluated on plain radiographs, greater than 35° is considered predictive of rotator cuff tears. The present prospective comparative study aimed, firstly, to develop a formula to calculate the amount of acromion that should be resected performing a lateral acromioplasty and, secondly, verify whether lateral acromioplasty to reduce the CSA associated with arthroscopic cuff repair decreased the rate of recurrence of the tears, and impacted favorably on clinical postoperative outcomes. Methods: Patients undergoing arthroscopic rotator cuff repair (RCR) for rotator cuff tears with a CSA greater than 35° were included in this study and divided into two groups, based on whether the CSA had been reduced by arthroscopic resection of the lateral portion of the acromion. A new mathematical formula was developed in order to quantify the amount of bone to be resected while performing the lateral acromioplasty. Patients with traumatic tears, previous surgery, osteoarthritis or plain radiographs, not classified as A1 according to Suter-Henninger, were excluded. Clinical and radiographic outcomes were assessed at a minimum of 2 years of follow-up considering the tear size. Results: 289 patients were included in this study. Thirty-seven were lost to follow-up. Group A (Lateral acromioplasty) patients included: 38 small tears, 30 medium tears, 28 large tears and 22 massive tears; Group B (control group) was composed of 40 small tears, 30 medium tears, 30 large tears and 23 massive tears. The Constants Score value and retear Rate were, respectively, significant higher (p = 0.007 and p = 0.004) and lower (p = 0.029 and p = 0.028) in Group A, both in the Small-and Medium-size subgroups. No complications were outlined. The mediolateral width of the acromion was reduced, according to the preoperatively calculated measure. Conclusion: Arthroscopic lateral acromioplasty decreased the CSA within the favorable range (30°–35°) in all patients treated, resecting the amount of bone predicted by the mathematical formula. Lateral acromioplasty is a safe and reproducible technique which may prevent recurrence of rotator cuff tears in patients with small and medium lesions. Level of evidence: II.