Zishang Zhu

Dr. Zishang Zhu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
YCYu Cui
Yu Cui
Zishang ZhuZishang Zhu
Zishang Zhu
Xudong ZhaoXudong Zhao
Xudong Zhao
ZLZhaomeng Li
Zhaomeng Li
Building energy modelling (BEM) is crucial for achieving energy conservation in buildings, but occupant energy-related behaviour is often oversimplified in traditional engineering simulation methods and thus causes a significant deviation between energy prediction and actual consumption. Moreover, the conventional fixed schedule-setting method is not applicable to the recently developed data-driven BEM which requires a more flexible and data-related multi-timescales schedule-setting method to boost its performance. In this paper, a data-based schedule setting method is developed by applying K-medoid clustering with Principal Component Analysis (PCA) dimensional reduction and Dynamic Time Warping (DTW) distance measurement to a comprehensive building energy historical dataset, partitioning the data into three different time scales to explore energy usage profile patterns. The Year–Month data were partitioned into two clusters; the Week–Day data were partitioned into three clusters; the Day–Hour data were partitioned into two clusters, and the schedule-setting matrix was developed based on the clustering result. We have compared the performance of the proposed data-driven schedule-setting matrix with default settings and calendar data using a single-layer neural network (NN) model. The findings show that for the data-driven predictive BEM, the clustering results-based data-driven schedule setting performs significantly better than the conventional fixed schedule setting (with a 25.7% improvement) and is more advantageous than the calendar data (with a 9.2% improvement). In conclusion, this study demonstrates that a data-related multi-timescales schedule matrix setting method based on cluster results of building energy profiles can be more suitable for data-driven BEM establishment and can improve the data-driven BEMs performance.

20 July 2022 in Buildings
Verified
Journal Article
Open access
PDF file
YCYu Cui
Yu Cui
Zishang ZhuZishang Zhu
Zishang Zhu
Xudong ZhaoXudong Zhao
Xudong Zhao
ZLZhaomeng Li
Zhaomeng Li
PQPeng Qin
Peng Qin
Conventional building energy models (BEM) for heating and cooling energy-consumption prediction without calibration are not accurate, and the commonly used manual calibration method requires the high expertise of modelers. Bayesian calibration (BC) is a novel method with great potential in BEM, and there are many successful applications for unknown-parameters calibrating and retrofitting analysis. However, there is still a lack of study on prediction model calibration. There are two main challenges in developing a calibrated prediction model: (1) poor generalization ability; (2) lack of data availability. To tackle these challenges and create an energy prediction model for office buildings in Guangdong, China, this paper characterizes and validates the BC method to calibrate a quasi-dynamic BEM with a comprehensive database including geometry information for various office buildings. Then, a case study analyzes the effectiveness and performance of the calibrated prediction model. The results show that BC effectively and accurately calibrates quasi-dynamic BEM for prediction purposes. The calibrated model accuracy (monthly CV(RMSE) of 0.59% and hourly CV(RMSE) of 19.35%) meets the requirement of ASHRAE Guideline 14. With the calibrated prediction model, this paper provides a new way to improve the data quality and integrity of existing building energy databases and will further benefit usability.

7 October 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Xiaojing HanXiaojing Han
Xiaojing Han
CZCheng Zeng
Cheng Zeng
Zishang ZhuZishang Zhu
Zishang Zhu
Yanyi SunYanyi Sun
Yanyi Sun
Xudong ZhaoXudong Zhao
Xudong Zhao
This research paper investigates a novel triangular honeycomb thermochemical energy storage reactor for low- and medium-temperature applications in buildings, emphasizing its potential to enhance sustainable heating. Using a validated 3D numerical model, the reactor’s performance is analyzed in depth across various configurations, focusing on key parameters such as energy storage density, pressure drop, internal air flow distribution, and round-trip efficiency. Results show that the reactor achieved an energy storage density of 872 kJ/kg and a round-trip thermal efficiency of 41.51% under optimal conditions. Additionally, the triangular honeycomb reactor (30°, 60, and 90°) configuration achieved the highest temperature lift of 48.7 °C. In a feasibility analysis for residential heating in northern China, the reactor with 30°, 60°, and 90° angles required 24.91% less volume to meet daily heating demands compared to other configurations. This study contributes valuable insights for the development of efficient, low-carbon heating solutions for low- and medium-temperature applications in buildings, offering interesting advancements in the field of thermochemical energy storage technology.