Yun-Da Li

Dr. Yun-Da Li

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2018 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
YLYun-Da Li
Yun-Da Li
CWChak-Bor Wong
Chak-Bor Wong
TTTsung-Ting Tsai
Tsung-Ting Tsai
PLPo-Liang Lai
Po-Liang Lai
CNChi Chien Niu
Chi Chien Niu
TFTsai-Sheng Fu
Tsai-Sheng Fu
Most guidelines recommend 6 to 12 weeks of parenteral antibiotic treatment for pyogenic spondylodiscitis. When surgical debridement is adequately performed, further intravenous antibiotic treatment duration can be reduced than that of conservative treatment alone theoretically. However, the appropriate duration of post-surgical parenteral antibiotic treatment is still unknown. This study aimed to identify the risk factors of recurrence and evaluate the appropriate duration after surgical intervention. This 3-year retrospective review included 102 consecutive patients who were diagnosed with pyogenic spondylodiscitis and underwent surgical intervention. Recurrence was defined as recurrent signs and symptoms and the need for another unplanned parenteral antibiotic treatment or operation within one year. This study included two major portions. First, independent risk factors for recurrence were identified by multivariable analysis, using the database of demographic information, pre-operative clinical signs and symptoms, underlying illness, radiographic findings, laboratory tests, intraoperative culture results, and treatment. Patients with any one of the risk factors were considered high-risk; those with no risk factors were considered low-risk. Recurrence rates after short-term (≤3 weeks) and long-term (> 3 weeks) parenteral antibiotic treatment were compared between the groups. Positive blood culture and paraspinal abscesses were identified as independent risk factors of recurrence. Accordingly, 59 (57.8%) patients were classified as low-risk and 43 (42.2%) as high-risk. Among the high-risk patients, a significantly higher recurrence rate occurred with short-term than with long-term antibiotic therapy (56.2% vs. 22.2%, p = 0.027). For the low-risk patients, there was no significant difference between short-term and long-term antibiotic therapy (16.0% vs. 20.6%, p = 0.461). The appropriate duration of parenteral antibiotic treatment in patients with pyogenic spondylodiscitis after surgical intervention could be guided by the risk factors. The duration of postoperative intravenous antibiotic therapy could be reduced to 3 weeks for patients without positive blood culture or abscess formation.

19 April 2012 in Journal of Infrared, Millimeter, and Terahertz Waves
Verified
Journal Article
Closed access
PDF file
QLQi Li
Qi Li
YLYun-Da Li
Yun-Da Li
SDSheng-Hui Ding
Sheng-Hui Ding
QWQi Wang
Qi Wang

22 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MHMing-kai Hsieh
Ming-kai Hsieh
YLYun-Da Li
Yun-Da Li
MLMu-Yi Liu
Mu-Yi Liu
CLChen-Xue Lin
Chen-Xue Lin
TTTsung-Ting Tsai
Tsung-Ting Tsai
CTChing-Lung Tai
Ching-Lung Tai
The proper screw geometry and pilot-hole size remain controversial in current biomechanical studies. Variable results arise from differences in specimen anatomy and density, uncontrolled screw properties and mixed screw brands, in addition to the use of different tapping methods. The purpose of this study was to evaluate the effect of bone density and pilot-hole size on the biomechanical performance of various pedicle screw geometries. Six screw designs, involving three different outer/inner projections of screws (cylindrical/conical, conical/conical and cylindrical/cylindrical), together with two different thread profiles (square and V), were examined. The insertional torque and pullout strength of each screw were measured following insertion of the screw into test blocks, with densities of 20 and 30 pcf, predrilled with 2.7-mm/3.2-mm/3.7-mm pilot holes. The correlation between the bone volume embedded in the screw threads and the pullout strength was statistically analyzed. Our study demonstrates that V-shaped screw threads showed a higher pullout strength than S-shaped threads in materials of different densities and among different pilot-hole sizes. The configuration, consisting of an outer cylindrical shape, an inner conical shape and V-shaped screw threads, showed the highest insertional torque and pullout strength at a normal and higher-than-normal bone density. Even with increasing pilot-hole size, this configuration maintained superiority.

10 July 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
SWSheng-Fen Wang
Sheng-Fen Wang
TTTsung-Ting Tsai
Tsung-Ting Tsai
YLYun-Da Li
Yun-Da Li
PCPing-Yeh Chiu
Ping-Yeh Chiu
MHMing-kai Hsieh
Ming-kai Hsieh
FKFu-Cheng Kao
Fu-Cheng Kao
Background: Postoperative immunosuppression is associated with blood loss and surgical trauma during surgery and subsequently predisposes patients to increased morbidity. Spine endoscopic surgery has been accepted as an effective surgical technique with less surgical trauma and less blood loss for the complication of infectious spondylodiscitis. Therefore, the aim of this study was to investigate whether PEIDF could reduce the morbidity rates for patients with infectious spondylodiscitis. Methods: We launched a retrospective cohort study on the comparison of the perioperative prognosis between PEIDF and conventional open surgery for single-level lumbar infectious spondylodiscitis in patients with poor physical health (ASA ≥ 4) from 2014 to 2019. Results: Forty-four patients were included in this study. Fifteen of them underwent PEIDF, and the rest of the 29 patients were treated with open surgery. Less surgical blood loss (p < 0.001) and intraoperative transfusions (p < 0.001) with a better decline of CRP (p = 0.017) were statistically significant in patients receiving PEIDF. Patients undergoing conventional open surgery encountered more postoperative sepsis (p = 0.030), a higher qSOFA score (p = 0.044), and prolonged-time for CRP normalization (p = 0.001). Conclusions: PEIDF minimizes a poor postoperative outcome due to less surgical trauma, intraoperative blood loss, and the need for a blood transfusion.

17 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MHMing-kai Hsieh
Ming-kai Hsieh
YLYun-Da Li
Yun-Da Li
YHYun-Ja Hsu
Yun-Ja Hsu
TTTsung-Ting Tsai
Tsung-Ting Tsai
PLPo-Liang Lai
Po-Liang Lai
CTChing-Lung Tai
Ching-Lung Tai
Replacement with larger diameter screws is always used in pedicle screw loosening but carries a risk of pedicle wall violation. A pedicle screw with more preserved bone stock is the preferred primary fixation choice. The purpose of this study was to evaluate whether a newly designed proximal-conical dual-thread screw with less bone occupancy provides fixation strength comparable to that of a traditional screw. Six types of pedicle screws based on three different shapes (cylindrical, conical, and proximal-conical) and two thread profiles (single-thread and dual-thread) were grouped. Conical and proximal-conical screws differed mainly in the slope of the outer diameter from the hub to the tip. Conical screws had an outer diameter (6.5 mm) that differed from the hub and tapered by 30% to an outer diameter (4.5 mm) at the tip and proximal-conical screws had the same outer diameter from the hub and tapered by 30% (4.5 mm) at 20 mm from the hub and then maintained the outer diameter (45 mm) to the tip. A total of 36 L4 Sawbones® vertebrae were used in the study and six trials for each screw group. The results of the imaging, screw volume in bone, insertion torque, and pullout force were analyzed. For screws with the same shape, insertion torque and pullout force were significantly higher for those in the dual-thread groups than for those in the single-thread groups (p < 0.05). For screws with the same thread profile, there was no significant difference in either biomechanical test between the different screw shapes (p > 0.05). Our results demonstrated that these proximal-conical dual-thread screws, with the property of relative bone stock preservation, display a comparable biomechanical performance to traditional dual-thread screws and a better performance than single-thread screws. This screw design could serve as the primary pedicle screw choice to reduce revision difficulty.

1 November 2013 in Optik
Verified
Journal Article
Closed access
YLYun-Da Li
Yun-Da Li
QLQi Li
Qi Li
JSJian-Yu She
Jian-Yu She
QWQi Wang
Qi Wang