Chijin Xiao

Dr. Chijin Xiao

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2014 in Surface and Coatings Technology
Verified
Journal Article
Closed access
SKS. Khatir
S. Khatir
AHA. Hirose
A. Hirose
CXChijin Xiao
Chijin Xiao

22 July 2019 in Nuclear Fusion
Verified
Journal Article
Open access
PDF file
WLWandong Liu
Wandong Liu
WMWenzhe Mao
Wenzhe Mao
TLTao Lan
Tao Lan
GZGe Zhuang
Ge Zhuang
JZJian Zheng
Jian Zheng
WDWeixing Ding
Weixing Ding
The Keda Torus eXperiment (KTX) is still operated in the commissioning phase, and preparation for the operation capability of the KTX phase II upgrade is underway. The diagnostics in the KTX have been greatly developed: (1) the terahertz interferometer has been upgraded to seven chords for electron density profile inversion; (2) a Thomson scattering system with a 5 Joule laser has been installed and commissioning is in progress; (3) a 3D movable probe system has been developed for the electromagnetic turbulence measurement; (4) double-foil soft x-ray imaging diagnostics have been set up and a bench test has been completed; (5) an edge capacitive probe has been installed for the radial electrical field measurement; (6) a multi-channel spectrograph system has been built for detecting impurities of carbon and oxygen. In addition, the design of a new compact torus injection system has been completed for feeding and momentum driving. Pilot research, such as the 3D reversed field pinch physics and electromagnetic turbulence, etc, have been conducted in the discharge status of the KTX. The 3D spectra characters of electromagnetic turbulence are firstly measured using a classical two-point technique by Langmuir probe arrays set on the 3D movable probe system and edge magnetic sensors. The forward scattering is collected by the interferometer system, which shows the potential for turbulence research. The electromagnetic turbulence is tentatively investigated in the KTX. The formation of a quasi-single-helicity state in the KTX regime is also preliminarily explored in simulation.

30 March 2022 in Plasma Science and Technology
Verified
Journal Article
Closed access
CCChen Chen
Chen Chen
TLTao Lan
Tao Lan
CXChijin Xiao
Chijin Xiao
GZGe Zhuang
Ge Zhuang
DKDefeng Kong
Defeng Kong
WLWandong Liu
Wandong Liu
A compact torus injection system, KTX-CTI, has been developed for the planned injection experiments on the Keda Torus eXperiment (KTX) reversed field pinch (RFP) device to investigate the physics and engineering issues associated with interaction between a compact torus (CT) and RFP. The key interests include fueling directly into the reactor center, confinement improvement, and the injection of momentum and helicity into the RFP discharges. The CT velocity and mass have been measured using a multichannel optical fiber interferometer, and for the first time the time evolution of the CT density profile during CT propagation is obtained. The effects of discharge parameters on the number of injected particles, CT velocity and CT density have been characterized: the maximum hydrogen CT plasma mass, m CT , is 50 μg, corresponding to 30% of the mass in a typical KTX plasma; the CT velocity exceeds 120 km s−1. It is observed for the first time that multiple CTs can be produced and emitted during a very short period (<100 μs) in one discharge, which is significant for the future study of repetitive CT injection, even with an ultra-high frequency.

1 June 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SZSen Zhang
Sen Zhang
CCChen Chen
Chen Chen
TLTao Lan
Tao Lan
WDWeixing Ding
Weixing Ding
GZGe Zhuang
Ge Zhuang
WLWandong Liu
Wandong Liu
An optical fiber Mach–Zehnder interferometer at a wavelength of 1.55 µm has been developed for measurements of high electron density on compact torus (CT) plasmas with a high time resolution of 0.1 µs and high phase resolution of 6.4 × 10−4 rad. To improve density measurement accuracy, the phase noise of the interferometer has been investigated in detail and optimized. In the bench test, the interferometer was calibrated using a piezoelectric ceramic actuator with known stroke. Initial results on CT plasma show that the optical fiber interferometer provides reliable density measurements at two spatial locations and the bulk velocity of plasma can be determined by the method of time of flight.

31 May 2007 in Materials Letters
Verified
Journal Article
Closed access
QYQiaoqin Yang
Qiaoqin Yang
SYSonglan Yang
Songlan Yang
CXChijin Xiao
Chijin Xiao
AHAkira Hirose
Akira Hirose

28 March 2017 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
ARA. Rohollahi
A. Rohollahi
SES. Elgriw
S. Elgriw
Debjyoti BasuDebjyoti Basu
Debjyoti Basu
SWS. Wolfe
S. Wolfe
AHA. Hirose
A. Hirose
CXChijin Xiao
Chijin Xiao
In the Saskatchewan torus-modified (STOR-M) tokamak, tangential compact torus injection (CTI) experiments have been performed with normal (counter-clockwise, CCW, top view) and reversed (clockwise, CW, top view) plasma current directions while the compact torus (CT) injection direction remains in the CCW direction. The intrinsic toroidal flow direction reverses when the discharge current is reversed. However, the change in the toroidal flow direction is always toward the CTI direction (CCW). It has been determined that the momentum in high density and high velocity CT is more than ten times larger than the intrinsic toroidal rotation momentum in the typical STOR-M plasma. Therefore, the modification of the plasma toroidal rotation velocity is attributed to momentum transfer from CT to the tokamak discharge.