A useful method for eliminating the detrimental effect of laser frequency instability on Brillouin signals by employing the self-heterodyne detection of Rayleigh and Brillouin scattering is presented. From the analysis of Brillouin scattering spectra from fibers with different lengths measured by heterodyne detection, the maximum usable pulse width immune to laser frequency instability is obtained to be about 4 µs in a self-heterodyne detection Brillouin optical time domain reflectometer (BOTDR) system using a broad-band laser with low frequency stability. Applying the self-heterodyne detection of Rayleigh and Brillouin scattering in BOTDR system, we successfully demonstrate that the detrimental effect of laser frequency instability on Brillouin signals can be eliminated effectively. Employing the broad-band laser modulated by a 130-ns wide pulse driven electro-optic modulator, the observed maximum errors in temperatures measured by the local heterodyne and self-heterodyne detection BOTDR systems are 7.9 °C and 1.2 °C, respectively.
A high-accuracy Brillouin frequency shift (BFS) measurement system for vector Brillouin optical time-domain analysis-based temperature sensor is proposed, in which double sideband modulation is used and the stimulated Brillouin scattering (SBS) gain and loss processes work together to generate a superimposed SBS phase-shift spectrum. The measurement principle is analyzed by mathematical modeling and the proof-of-concept experiment is performed by using a 100-m long standard single-mode fiber. The theoretical and experimental results reveal that the temperature sensitivity of BFS obtained from the measured SBS phase-shift spectrum is , and the measurement error of temperature is only half that in traditional single sideband-based system, which indicates that the proposed technique can realize high-accuracy temperature measurement and have huge potential in the field of long-distance and high-accuracy sensing.
Partial discharge signals are often interfered by white noise and narrowband noise, which makes it difficult to locate the partial discharge source. To tackle this intricate issue, this paper proposes an improved variational Mode Decomposition (VMD) noise reduction method. Initially, the method optimizes the VMD by employing the Crested Porcupine Optimizer (CPO). Subsequently, modal screening is carried out in accordance with a specific criterion. Finally, noise reduction is implemented through an improved 3σ method. Via noise - reduction simulation experiments, the superiority of this method is validated, and comparisons are made with several other methods, wherein this method is capable of boosting the Signal - to - Noise Ratio (SNR) by up to 50, elevating the correlation coefficient to over 0.99, and reducing the Mean Squared Error (MSE) by 99%. Meanwhile, the practicality of this method is confirmed through localization experiments.