Hichem Moulahoum

Dr. Hichem Moulahoum

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
HMHichem Moulahoum
Hichem Moulahoum
FGFaezeh Ghorbanizamani
Faezeh Ghorbanizamani

20 July 2021 in Bioconjugate Chemistry
Verified
Journal Article
Closed access
HMHichem Moulahoum
Hichem Moulahoum
FGFaezeh Ghorbanizamani
Faezeh Ghorbanizamani
FZFigen Zihnioglu
Figen Zihnioglu
STSuna Timur
Suna Timur

4 December 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
SŞSerdar ŞANLI
Serdar ŞANLI
FGFaezeh Ghorbani-Zamani
Faezeh Ghorbani-Zamani
HMHichem Moulahoum
Hichem Moulahoum
ZGZinar Pinar Gumus
Zinar Pinar Gumus
HCHakan Coskunol
Hakan Coskunol
STSuna Timur
Suna Timur

7 September 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SBSimge Balaban
Simge Balaban
EMEzgi Man Ezgi Man
Ezgi Man Ezgi Man
DHDuygu Harmancı
Duygu Harmancı
SRSERIFE TOZAN RUZGAR
SERIFE TOZAN RUZGAR
SŞSerdar ŞANLI
Serdar ŞANLI
STSuna Timur
Suna Timur
Diagnostic biomarkers based on epigenetic changes such as DNA methylation are promising tools for early cancer diagnosis. However, there are significant difficulties in directly and specifically detecting methylated DNA regions. Here, we report an electrochemical sensing system based on magnetic nanoparticles that enable a quantitative and selective analysis of the methylated septin9 (mSEPT9) gene, which is considered a diagnostic marker in early stage colorectal cancer (CRC). Methylation levels of SEPT9 in CRC samples were successfully followed by the selective recognition ability of a related peptide nucleic acid (PNA) after hybridization with DNA fragments in human patients’ serums and plasma (n = 10). Moreover, this system was also adapted into a point-of-care (POC) device for a one-step detection platform. The detection of mSEPT9 demonstrated a limit of detection (LOD) value of 0.37% and interference-free measurement in the presence of branched-chain amino acid transaminase 1 (BCAT1) and SRY box transcription factor 21 antisense divergent transcript 1 (SOX21-AS1). The currently proposed functional platform has substantial prospects in translational applications of early CRC detection.

1 November 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
FGFaezeh Ghorbanizamani
Faezeh Ghorbanizamani
HMHichem Moulahoum
Hichem Moulahoum
FZFigen Zihnioglu
Figen Zihnioglu
SESerap Evran
Serap Evran
CCCandan Cicek
Candan Cicek
STSuna Timur
Suna Timur

3 March 2022 in Talanta
Verified
Journal Article
Closed access
CDCeren Durmus
Ceren Durmus
SHSimge Balaban Hanoglu
Simge Balaban Hanoglu
DHDuygu Harmancı
Duygu Harmancı
HMHichem Moulahoum
Hichem Moulahoum
KTKerem Tok
Kerem Tok
STSuna Timur
Suna Timur