Atin Bakhshi

Mr. Atin Bakhshi

University of Tehran, Tehran, Tehrān, Iran
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Malihe FarasatMalihe Farasat
Malihe Farasat
Ehsan AalaeiEhsan Aalaei
Ehsan Aalaei
Saeed Kheirati RoniziSaeed Kheirati Ronizi
Saeed Kheirati Ronizi
Atin BakhshiAtin Bakhshi
Atin Bakhshi
SMShaghayegh Mirhosseini
Shaghayegh Mirhosseini
Navid KashaninejadNavid Kashaninejad
Navid Kashaninejad
Separation and detection of cells and particles in a suspension are essential for various applications, including biomedical investigations and clinical diagnostics. Microfluidics realizes the miniaturization of analytical devices by controlling the motion of a small volume of fluids in microchannels and microchambers. Accordingly, microfluidic devices have been widely used in particle/cell manipulation processes. Different microfluidic methods for particle separation include dielectrophoretic, magnetic, optical, acoustic, hydrodynamic, and chemical techniques. Dielectrophoresis (DEP) is a method for manipulating polarizable particles’ trajectories in non-uniform electric fields using unique dielectric characteristics. It provides several advantages for dealing with neutral bioparticles owing to its sensitivity, selectivity, and noninvasive nature. This review provides a detailed study on the signal-based DEP methods that use the applied signal parameters, including frequency, amplitude, phase, and shape for cell/particle separation and manipulation. Rather than employing complex channels or time-consuming fabrication procedures, these methods realize sorting and detecting the cells/particles by modifying the signal parameters while using a relatively simple device. In addition, these methods can significantly impact clinical diagnostics by making low-cost and rapid separation possible. We conclude the review by discussing the technical and biological challenges of DEP techniques and providing future perspectives in this field.
1

8 December 2021 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
Malihe FarasatMalihe Farasat
Malihe Farasat
SCSeyede Maede Chavoshi
Seyede Maede Chavoshi
Atin BakhshiAtin Bakhshi
Atin Bakhshi
AVAref Valipour
Aref Valipour
Majid BadieirostamiMajid Badieirostami
Majid Badieirostami
Circulating tumor cells (CTCs) have been widely considered as novel biomarkers for the clinical diagnosis of cancer. CTCs are the cells detached from the parent tumors and shed into the blood stream to initiate tumor metastasis. Although CTCs are rare, their detection in one’s blood sample is essential for cancer early diagnosis and for starting the treatment procedure. Here, we introduce a novel method for trapping CTCs using dielectrophores, which effectively employs pores of a replaceable porous membrane as CTC traps. The applied dielectrophoretic force efficiently traps and holds CTCs in a stable position and further enables us to perform various on-chip analysis with them. First, using finite element method, the performance of the system was simulated for different physical conditions. Then, the chip was fabricated and its trapping performance was experimentally validated. Cells were entered into the microchannel and trapped in the pores of a polydimethylsiloxane membrane. The proposed microfluidic chip is capable of detecting rare cells in a large cell population.
1

20 June 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
Malihe FarasatMalihe Farasat
Malihe Farasat
Ehsan AalaeiEhsan Aalaei
Ehsan Aalaei
Saeed Kheirati RoniziSaeed Kheirati Ronizi
Saeed Kheirati Ronizi
Atin BakhshiAtin Bakhshi
Atin Bakhshi
SMShaghayegh Mirhosseini
Shaghayegh Mirhosseini
Navid KashaninejadNavid Kashaninejad
Navid Kashaninejad
Separation and detection of cells and particles in a suspension are essential for various applications, including biomedical investigations and clinical diagnostics. Microfluidics realizes the miniaturization of analytical devices by controlling the motion of a small volume of fluids in microchannels and microchambers. Accordingly, microfluidic devices have been widely used in particle/ cell manipulation processes. Different microfluidic methods for particle separation include dielectrophoretic, magnetic, optical, acoustic, hydrodynamic, and chemical techniques. Dielectrophoresis (DEP) is a method for manipulating polarizable particles’ trajectories in non-uniform electric fields using unique dielectric characteristics. It provides several advantages for dealing with neutral bioparticles owing to its sensitivity, selectivity, and noninvasive nature. This review provides a detailed study on the signal-based DEP methods that use the applied signal parameters, including frequency, amplitude, phase, and shape for cell/particle separation and manipulation. Rather than employing complex channels or time-consuming fabrication procedures, these methods realize sorting and detecting the cells/particles by modifying the signal parameters while using a simple device. In addition, these methods can significantly impact clinical diagnostics by making low-cost and rapid separation possible.
1