P Srinivas Kishore

Prof. P Srinivas Kishore


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2019 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
AKAkula Naresh Kumar
Akula Naresh Kumar
PKP Srinivas Kishore
P Srinivas Kishore
KRKalidindi Brahma Raju
Kalidindi Brahma Raju
NKNanthagopal Kasianantham
Nanthagopal Kasianantham
Bragadeshwaran AshokBragadeshwaran Ashok
Bragadeshwaran Ashok

5 November 2020 in Journal of Dispersion Science and Technology
Verified
Journal Article
Closed access
NNN. S. Naveen
N. S. Naveen
PKP Srinivas Kishore
P Srinivas Kishore
In the present study, forced convective heat transfer of a Water-EG coolant has been compared with Water-EG based nanocoolant in a radiator. Conventional coolant Water-EG was considered in the ratio of 70:30 as a base fluid, for that different proportions of 0.1, 0.2 and 0.3 Vol% has been prepared by the addition of graphene nanoparticles. Graphene nanofluid was synthesized by two-step method. Experimental studies were conducted in a radiator by altering the flow rates and inlet temperature of the coolant in the ranges of 2, 4, 6 and 8 L/min and 50, 60 and 70 °C. Heat transfer parameters like Heat transfer rate, Convective heat transfer co-efficient, Nusselt number, Reynolds number and friction factor are evaluated experimentally. Graphical Abstract

26 June 2021 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
SVSireesha Veeramachaneni
Sireesha Veeramachaneni
PKP Srinivas Kishore
P Srinivas Kishore
DVDharma Rao Vedula
Dharma Rao Vedula
ASA. Brusly Solomon
A. Brusly Solomon
VHV. Sree Harsha
V. Sree Harsha

2 August 2020 in Experimental Heat Transfer
Verified
Journal Article
Closed access
SVSireesha Veeramachaneni
Sireesha Veeramachaneni
PKP Srinivas Kishore
P Srinivas Kishore
DVDharma Rao Vedula
Dharma Rao Vedula
ASA. Brusly Solomon
A. Brusly Solomon
Experiments have been conducted on a flat rectangular loop heat pipe with water and methanol at heat loads from 40 to 320 W at three orientations of the heat pipe (0°, 45°, 90°) and two filling ratios (33% and 50%). Performance parameters such as thermal resistance, effective thermal conductivity and capillary limit are calculated from the experimental data. The results exhibited that the thermal performance of water is better than methanol with least thermal resistance 0.13 K/W, maximum capillary limit 2626.72 W and an effective thermal conductivity 84490.48 W/mK at a heat load 320 W in horizontal position for 33% filling ratio.

1 January 2024 in Journal of Thermal Engineering
Verified
Journal Article
Open access
PDF file
KVK. P. V. Krishna Varma
K. P. V. Krishna Varma
NNN. S. Naveen
N. S. Naveen
PKP Srinivas Kishore
P Srinivas Kishore
SPSatish Pujari
Satish Pujari
KJKrishna Jogi
Krishna Jogi
VRV. Dhana Raju
V. Dhana Raju
This research work aims to optimize double pipe heat exchanger performance using Taguchi, ANOVA, and ANN. Experimental trials involved varying ferric oxide nanoparticles, cut radius, and volume-based flow rate. Twisted tapes with ratios of 3, 5, and 7 were placed within the tube. Assessed heat transfer characteristics included h, Nu, ff, and thermal performance factor. Taguchi, ANOVA, and ANN optimization techniques were applied to the experimental data. A Taguchi optimization using an L9 orthogonal array focused on input attributes (Vol % of nanoparticles, flow rate, radius of cut), with output attributes being heat transfer co-efficient (h), Nusselt number (Nu), friction factor(ff) and thermal performance factor. Results revealed a notable flow rate effect on enhancing h, Nu, and ff, while the addition of nanoparticles significantly influenced thermal performance. Taguchi and ANOVA were conducted using MINI Tab and ANN was implemented through MATLAB. Test data demonstrated that nanoparticle dispersants in nanofluid significantly improved heat transfer properties, consistent with the noteworthy improvement indicated by optimization techniques. The convective heat transfer coefficient parameter showed improvement with a coolant flow rate of 50.29% and a volume of nanoparticles at 27.32%. The enhancement of Nusselt number (Nu) was influenced by a coolant flow rate of 50.34% and a volume percent of nanoparticles at 34.25%. The thermal performance factor was significantly influenced by the volume percent of nanoparticles (79.75%) and the radius of cut (3.83%).The experimental data aligned well with findings from Taguchi and ANN.