These years, disease-causing and disabling diseases have caused great concern. Neurological musculoskeletal disorders are diverse and affect people of a wide range of ages. And the lack of comprehensive diagnostic methods places a huge burden on healthcare systems and social economies. In this paper, the current status of clinical research on neuromuscular diseases is introduced, and the advantages of magnetic field measurement compared with clinical diagnostic methods are illustrated. A comprehensive description of the related technology of superconducting quantum interference devices (SQUIDs), magnetic field detection noise suppression scheme, the development trend of the sensor detection system, and the application and model establishment of the neuromuscular magnetic field is also given in this paper. The current research and development trends worldwide are compared simultaneously, and finally the conclusions and outlook are put forward. Based on the description of the existing literature and the ideas of other researchers, the next development trends and my own research ideas are presented in this paper, that is, starting from the establishment of a neuromuscular model, combining medical and industrial work, designing a sensor system that meets clinical needs, and laying the foundation for the clinical application of a bio-magnetic system. This review promotes a combination between medicine and industry, and guides researchers on considering the challenges of sensor development in terms of clinical needs. In addition, in this paper, the development trends are described, including the establishment of the model, the clinical demand for sensors, and the challenges of system development so as to give certain guidance to researchers.
28 June 2024 in IEEE Transactions on Applied Superconductivity
Marine weak magnetic measurement is one of the important research directions today. Detecting and identifying undersea cables is a key task in marine weak magnetic measurement. Studying the principle of magnetic anomaly of these cables and establish their magnetic anomaly models is the basis of magnetic detection, location and recognition. The magnetic field of an undersea cable is mainly composed of the current and the cable material itself. When the sensor is far from the cable, the weak magnetic field's strength is at the pico-Tesla (pT) level or even at the femto-Tesla (fT) level. For detecting undersea cables, a theoretical calculation model for the transmission characteristics of the magnetic field in the marine environment had been derived, and its attenuation rule in the ocean was analyzed in this paper. A simulation model for the cables had been established. Simulation results showed that SQUID (Superconducting QUantum Interference Device) can detect and identify cables at distances over 1 km.
28 June 2024 in IEEE Transactions on Applied Superconductivity
The brightness, chrominance and uniformity of Organic Light-Emitting Diode (OLED) display depend on the driver current through it, so the precise detection of OLED current has always been a key step in the production of the display. To achieve non-destructive detection of encapsulated OLED current, this paper introduces a method of Scanning SQUID Microscope (SSM) based on High Tc SQUID. Firstly, the OLED current-magnetic model using Biot-Savart law was established, in which the distance between OLED and SQUID is 500 µm, the SQUID washer is a square shape with a side length of 50 µm, and OLED maximum pixel current is 100 µA. When only one pixel is illuminated, the maximum magnetic is about 344 nT located at near common trace line, which is very different from optical detection. At last, in order to study the location of pixel defects, this paper investigated the magnetic field difference between lighting up 8 pixels and 6 pixels. And found that the maximum magnetic field value occurred near the common electrode, and the position of the magnetic field difference was related to the location of pixel defects.
At present, the reliability of faulted line selection of single-phase earth fault in distribution network is generally low. This paper proposes a segmented network method based faulted line selection strategy. And the strategy is verified through an emtp simulation by modeling a 10kV ungrounded distribution network. The simulation results prove that the proposed strategy can realize reliable selection of faulted line with single-phase earth fault in distribution network through a small number of switching operations, and it is helpful to deal with single-phase earth fault in distribution network automatically.
These years, disease-causing and disabling diseases have caused great concern. Neurological, musculoskeletal disorders are diverse and affect people of a wide range of ages. And the lack of comprehensive diagnostic methods places a huge burden on healthcare systems and social economies. In this paper, the current status of clinical research on neuromuscular diseases is introduced, and the advantages of magnetic field measurement compared with clinical diagnostic methods are illustrated. The paper makes a comprehensive description about the related technology of superconducting quantum interference devices (SQUIDs), magnetic field detection noise suppression scheme, the development trend of sensor detection system, and the application and model establishment of neuromuscular magnetic field. The current researches and developments in the worldwide are compared simultaneously in this paper and finally the conclusions and outlook are put forward. This review will be very interesting and helpful to the scientific community.
28 June 2024 in IEEE Transactions on Applied Superconductivity
Fetal Magnetocardiography (fMCG) is a non-invasive technique for recording and analyzing the magnetic elements of the fetal cardiac cycle, emanating from the hearts' electrical activities. To improve the detection accuracy of fMCG, environmental noise suppression is essential. This paper presents a robust approach that combines an active compensation system with a SQUID gradiometer to suppress environmental noise. And proposed an evaluation method that can intuitively reflect the compensation effect. Initially, the sensor's operational environment was thoroughly assessed, leading to the adoption of targeted noise suppression strategies across various frequency bands. A three-axis Helmholtz coil-based compensation system was developed, achieving an impressive 25 decibel (dB) noise rejection in 100 Hz. Additionally, a second-order gradiometer effectively suppressed noise by 35 dB in the same frequency.