We developed a 51-channel magnetocardiography (MCG) system based on weakly damped dc superconducting quantum interference device (SQUID) magnetometers. In previous works, the system consisted of 36 sensing magnetometers, 12 reference magnetometers, and a three-component vector magnetometer. In this paper, we have describe the optimizing processes of software gradiometer configurations in different magnetically shielded rooms (MSRs). Using a simulated MCG signal generated by a small coil driven by electrocardiograph, we have quantitatively evaluated the signal quality through four key performance indices, which are (1) correlation in time domain, (2) correlation in frequency domain, (3) relative heights of different peaks, and (4) magnetic field map of simulating coil. After data processing and analysis of these four parameters, optimized software gradiometers of first or second order can be formed by using specific reference magnetometer signals to compensate the signals of 36 sensing magnetometers in each MSR. Also, the MCG signals of an adult have been detected by using these optimized configurations. The magnetic field maps and typical parameters at T-peak have been extracted and compared, and the results with high consistency confirm the effectiveness of optimization processes.
27 December 2018 in IEEE Transactions on Applied Superconductivity
Gradiometer module plays a significant role in fetal magnetocardiography (fMCG) system and its performance de-termines the signal qualities directly. In order to obtain the best signal-to-noise ratio (SNR) of the fMCG signals in a thin magnet-ically shielding room (tMSR), the baseline of the axial gradiome-ters need to be optimized. In this paper, direct current supercon-ducting quantum interference device (dc SQUID) which is com-posed of weakly damped Josephson Junctions with βc>3 and has a flux-to-voltage transfer coefficient of 500 μV/Ω0 is employed for our gradiometers. Superconducting connectivity technique is uti-lized to connect input coil and pickup coil. First-order gradiome-ters with different baselines are thus developed. After the evalua-tion of the magnetic flux density and gradient flux density inside the tMSR, measurement of fMCG signals are taken with the gra-diometers mentioned above. The simulated fetal QRS peak sig-nals about 2.5 pT could easily be identified in the real-time gra-diometer module outputs with a signal-to-noise ratio larger than 11dB.
These years, disease-causing and disabling diseases have caused great concern. Neurological musculoskeletal disorders are diverse and affect people of a wide range of ages. And the lack of comprehensive diagnostic methods places a huge burden on healthcare systems and social economies. In this paper, the current status of clinical research on neuromuscular diseases is introduced, and the advantages of magnetic field measurement compared with clinical diagnostic methods are illustrated. A comprehensive description of the related technology of superconducting quantum interference devices (SQUIDs), magnetic field detection noise suppression scheme, the development trend of the sensor detection system, and the application and model establishment of the neuromuscular magnetic field is also given in this paper. The current research and development trends worldwide are compared simultaneously, and finally the conclusions and outlook are put forward. Based on the description of the existing literature and the ideas of other researchers, the next development trends and my own research ideas are presented in this paper, that is, starting from the establishment of a neuromuscular model, combining medical and industrial work, designing a sensor system that meets clinical needs, and laying the foundation for the clinical application of a bio-magnetic system. This review promotes a combination between medicine and industry, and guides researchers on considering the challenges of sensor development in terms of clinical needs. In addition, in this paper, the development trends are described, including the establishment of the model, the clinical demand for sensors, and the challenges of system development so as to give certain guidance to researchers.
High-precision microelectromechanical system (MEMS) accelerometers have wide application in the military and civil fields. The closed-loop microaccelerometer interface circuit with switched capacitor topology has a high signal-to-noise ratio, wide bandwidth, good linearity, and easy implementation in complementary metal oxide semiconductor (CMOS) process. Aiming at the urgent need for high-precision MEMS accelerometers in geophones, we carried out relevant research on high-performance closed-loop application specific integrated circuit (ASIC) chips. According to the characteristics of the performance parameters and output signal of MEMS accelerometers used in geophones, a high-precision closed-loop interface ASIC chip based on electrostatic time-multiplexing feedback technology and proportion integration differentiation (PID) feedback control technology was designed and implemented. The interface circuit consisted of a low-noise charge-sensitive amplifier (CSA), a sampling and holding circuit, and a PID feedback circuit. We analyzed and optimized the noise characteristics of the interface circuit and used a capacitance compensation array method to eliminate misalignment of the sensitive element. The correlated double sampling (CDS) technology was used to eliminate low-frequency noise and offset of the interface circuit. The layout design and engineering batch chip were fabricated by a standard 0.35 μm CMOS process. The active area of the chip was 3.2 mm × 3 mm. We tested the performance of the accelerometer system with the following conditions: power dissipation of 7.7 mW with a 5 V power supply and noise density less than 0.5 μg/Hz1/2. The accelerometers had a sensitivity of 1.2 V/g and an input range of ±1.2 g. The nonlinearity was 0.15%, and the bias instability was about 50 μg.
30 September 2021 in IEEE Transactions on Applied Superconductivity
The magnetic shielding room (MSR), which is mainly composed of permalloy and aluminum layer, is widely used in the measurement of near-zero magnetic environment. This paper mainly uses ANSYS Maxwell software to simulate MSR and improve its design method. The shielding effectiveness (SE) is introduced to evaluate its performance. The experimental data show that the shielding parameter SE has a best value under certain conditions. SE is inversely proportional to the size of the shielding space, and is proportional to the thickness of each layer, and there is an optimal value for the gap between the two layers. This equivalent circuit to the MSR can be explained well.
7 September 2024 in Biomedical Signal Processing and Control