The magnetic fluid seal is widely used in the high-speed mechanical devices. And the temperature of the seal increases with the viscous heating under the high shearing rate in the magnetic fluid. However, the influence of the temperature on the sealing performance has not been studied quantitatively in the available research. In this paper, the change rule of magnetic fluid temperature and the influence on the sealing performance is researched through the simulation and experiment methods. The thermal field simulation is conducted with the heat generation in the fluid. To calculate the decrease of the magnetic properties quantitatively, the magnetization curves under different temperatures are measured to carry out the relationship between the saturation magnetization and temperature. Based on the magnetization curve result, the two-phase flow between air and magnetic fluid is solved under different shaft rotation speeds with the influence of temperature change. Besides, the sealing experiment is conducted with the highest rotation speed of 8000 rpm. The result of simulation and experiment show good consistency, the sealing capacity decreases with the rise of rotation speed.
Compared with a ferrofluid (FF) seal used as a sealing material, magnetorheological (MR) fluid has higher sealing pressure at the same condition. This is because MR fluid not only has magnetic property but also shows obviously elasto-plastic performance, which differs from FFs, under the magnetic field. On this basis, this paper analyzed, respectively, the static seal performance of MR fluids and FFs based on their magnetic properties through experimental and numerical studies. The results showed that an obvious pressure drop happened when the pressure is about 400 kPa in seal cavity for MR fluid seal, but the pressure was quickly down to around 390 kPa; nevertheless, the maximum pressure of the FF seal is 200 kPa, and the seal time with leak-free is about 2.5 min, and then the value quickly goes down to zero. The maximum pressure of every pole tooth of FF seal is about 11.11 kPa. The pressure of MR fluid seal is 21.67 kPa when there is a significant decrease during pressuring, and the maximum pressure of every pole tooth of MR fluid seal is 41.37 kPa. At last, the relationship of the sealing pressure of MR fluid seal with the time was derived.
Most magnetic fluid seals are multi-teeth structures for the high sealing capacity. However, the pressure transfer mechanism in the multi-teeth magnetic fluid seal is only carried out through experimental methods. In this paper, a simulation method is presented to solve the two-phase flow of magnetic fluid and air in the sealing clearance. The boundary of magnetic fluid is obtained by Volume of Fraction method. Besides, a plane multi-teeth magnetic fluid seal is presented to observe the magnetic fluid barrier and obtain the pressure change during the pressure transfer process. The result shows that fluid barrier ruptures when the pressure difference exceeds the sealing capacity. The pressure is transferred one chamber by one chamber in the multi-teeth magnetic fluid seal.
The magnetic fluid seal is one of the best known and widely used technical applications of magnetic fluid. However, the boundary and the flow regime with the rotation shaft cannot be observed by the experiment method. This paper presents a novel numerical simulation method to obtain the boundary and the velocity of the fluid in seals. The magnetic field of the seal is solved by the finite-element method, and the Navier-Stokes equations of the magnetic fluid based on the influence of magnetic force are solved by the finite-volume method. The two-phase flow is solved by the volume of fluid method. The seal capacities of the rectangle tooth and the trapezoid tooth with different rotation velocities are obtained. The result shows that the seal capacity decreases with the increase in the rotation velocity.
With the development of science technology, ferrofluid seal has been intensively applied in mechanical industry, but more and more larger sealing stages are needed. At present, the literature mostly concentrated on numerical analysis with few pole pieces ferrofluid seals and focused on the critical pressure value in one-stage magnetic fluid seal, lacking of numerical simulation and experimental validation on the static pressure of multi-stage ferrofluid seals. On this basis, the analysis of larger number of sealing stages is presented. And numerical simulation along with experiment investigation was used to study the seal capacity of ferrofluids in different seal gaps and different seal stages in this paper. The results show that the theoretical value is well coincident with experimental value when the sealing gap is less than 0.2 mm. Increase the number of the pole tooth can significantly improve the seal capacity of ferrofluid seal, but the sealing pressure of ferrofluids does not increase linearly with the addition of the number of pole teeth. For the new structure, the pressure of one-stage pole tooth has more than doubled as the sealing clearance is 0.2 mm and 3.5 times increase when the sealing gap is 0.3 mm.
Magnetic fluid is a new type of functional materials. The seal of reciprocating shaft is a typical application of the magnetic fluid. However, there is little research on the magnetic fluid reciprocating seals, thus improving the sealing life and seal capacity is the key problem of studying the reciprocating seals. This paper presents a structure of the seal to test the sealing life and other characteristics. The magnetic field of the seal is estimated using the finite-element method. The thickness of the magnetic fluid on the surface of reciprocating shaft and the flow rate of magnetic fluid are obtained theoretically. The experimental result shows that the static seal capacity is related to the fluid volume. The static seal capacity obtained by experiment is approximately equal to the value through the simulation with sufficient magnetic fluid. The relationship between sealing life and the motion of the reciprocating shaft is obtained experimentally. The sealing life decreases rapidly with the increase of the stroke and velocity.