Dino Di Carlo

Dr. Dino Di Carlo


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
DCDino Di Carlo
Dino Di Carlo
Despite the common wisdom that inertia does not contribute to microfluidic phenomena, recent work has shown a variety of useful effects that depend on fluid inertia for applications in enhanced mixing, particle separation, and bioparticle focusing. Due to the robust, fault-tolerant physical effects employed and high rates of operation, inertial microfluidic systems are poised to have a critical impact on high-throughput separation applications in environmental cleanup and physiological fluids processing, as well as bioparticle focusing applications in clinical diagnostics. In this review I will discuss the recent accelerated progress in developing prototype inertial microfluidic systems for a variety of applications and attempt to clarify the fundamental fluid dynamic effects that are being exploited. Finally, since this a nascent area of research, I will suggest some future promising directions exploiting fluid inertia on the microscale.

1 June 2015 in Nature Materials
Verified
Journal Article
Closed access
PDF file
DGDonald R. Griffin
Donald R. Griffin
WWWestbrook M. Weaver
Westbrook M. Weaver
PSPhilip O. Scumpia
Philip O. Scumpia
DCDino Di Carlo
Dino Di Carlo
TSTatiana Segura
Tatiana Segura

25 April 2010 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
DGDaniel R. Gossett
Daniel R. Gossett
WWWestbrook M. Weaver
Westbrook M. Weaver
AMAlbert J. Mach
Albert J. Mach
SHSoojung Claire Hur
Soojung Claire Hur
HTHenry Tat Kwong Tse
Henry Tat Kwong Tse
DCDino Di Carlo
Dino Di Carlo
Cell separation and sorting are essential steps in cell biology research and in many diagnostic and therapeutic methods. Recently, there has been interest in methods which avoid the use of biochemical labels; numerous intrinsic biomarkers have been explored to identify cells including size, electrical polarizability, and hydrodynamic properties. This review highlights microfluidic techniques used for label-free discrimination and fractionation of cell populations. Microfluidic systems have been adopted to precisely handle single cells and interface with other tools for biochemical analysis. We analyzed many of these techniques, detailing their mode of separation, while concentrating on recent developments and evaluating their prospects for application. Furthermore, this was done from a perspective where inertial effects are considered important and general performance metrics were proposed which would ease comparison of reported technologies. Lastly, we assess the current state of these technologies and suggest directions which may make them more accessible. A wide range of microfluidic technologies have been developed to separate and sort cells by taking advantage of differences in their intrinsic biophysical properties

30 April 2012 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
DGDaniel R. Gossett
Daniel R. Gossett
HTHenry T. K. Tse
Henry T. K. Tse
SLSerena A. Lee
Serena A. Lee
YYYong Ying
Yong Ying
ALAnne G. Lindgren
Anne G. Lindgren
DCDino Di Carlo
Dino Di Carlo
Cell state is often assayed through measurement of biochemical and biophysical markers. Although biochemical markers have been widely used, intrinsic biophysical markers, such as the ability to mechanically deform under a load, are advantageous in that they do not require costly labeling or sample preparation. However, current techniques that assay cell mechanical properties have had limited adoption in clinical and cell biology research applications. Here, we demonstrate an automated microfluidic technology capable of probing single-cell deformability at approximately 2,000 cells/s. The method uses inertial focusing to uniformly deliver cells to a stretching extensional flow where cells are deformed at high strain rates, imaged with a high-speed camera, and computationally analyzed to extract quantitative parameters. This approach allows us to analyze cells at throughputs orders of magnitude faster than previously reported biophysical flow cytometers and single-cell mechanics tools, while creating easily observable larger strains and limiting user time commitment and bias through automation. Using this approach we rapidly assay the deformability of native populations of leukocytes and malignant cells in pleural effusions and accurately predict disease state in patients with cancer and immune activation with a sensitivity of 91% and a specificity of 86%. As a tool for biological research, we show the deformability we measure is an early biomarker for pluripotent stem cell differentiation and is likely linked to nuclear structural changes. Microfluidic deformability cytometry brings the statistical accuracy of traditional flow cytometric techniques to label-free biophysical biomarkers, enabling applications in clinical diagnostics, stem cell characterization, and single-cell biophysics.

28 May 2014 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
HAHamed Amini
Hamed Amini
WLWonhee Lee
Wonhee Lee
DCDino Di Carlo
Dino Di Carlo
Microfluidics has experienced massive growth in the past two decades, and especially with advances in rapid prototyping researchers have explored a multitude of channel structures, fluid and particle mixtures, and integration with electrical and optical systems towards solving problems in healthcare, biological and chemical analysis, materials synthesis, and other emerging areas that can benefit from the scale, automation, or the unique physics of these systems. Inertial microfluidics, which relies on the unconventional use of fluid inertia in microfluidic platforms, is one of the emerging fields that make use of unique physical phenomena that are accessible in microscale patterned channels. Channel shapes that focus, concentrate, order, separate, transfer, and mix particles and fluids have been demonstrated, however physical underpinnings guiding these channel designs have been limited and much of the development has been based on experimentally-derived intuition. Here we aim to provide a deeper understanding of mechanisms and underlying physics in these systems which can lead to more effective and reliable designs with less iteration. To place the inertial effects into context we also discuss related fluid-induced forces present in particulate flows including forces due to non-Newtonian fluids, particle asymmetry, and particle deformability. We then highlight the inverse situation and describe the effect of the suspended particles acting on the fluid in a channel flow. Finally, we discuss the importance of structured channels, i.e. channels with boundary conditions that vary in the streamwise direction, and their potential as a means to achieve unprecedented three-dimensional control over fluid and particles in microchannels. Ultimately, we hope that an improved fundamental and quantitative understanding of inertial fluid dynamic effects can lead to unprecedented capabilities to program fluid and particle flow towards automation of biomedicine, materials synthesis, and chemical process control.

3 March 2009 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
DCDino Di Carlo
Dino Di Carlo
JFJon F.
Jon F.
KHKatherine J. Humphry
Katherine J. Humphry
HSHoward A. Stone
Howard A. Stone
MTMehmet Toner
Mehmet Toner
Nonlinearity in finite-Reynolds-number flow results in particle migration transverse to fluid streamlines, producing the well-known “tubular pinch effect” in cylindrical pipes. Here we investigate these nonlinear effects in highly confined systems where the particle size approaches the channel dimensions. Experimental and numerical results reveal distinctive dynamics, including complex scaling of lift forces with channel and particle geometry. The unique behavior described in this Letter has broad implications for confined particulate flows.