Soojung Claire Hur

Prof. Soojung Claire Hur

Department of Mechanical Engineering and Oncology, Johns Hopkins University 3400 N Charles St, Latrobe 221, Baltimore, MD 21211
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2010 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
DGDaniel R. Gossett
Daniel R. Gossett
WWWestbrook M. Weaver
Westbrook M. Weaver
AMAlbert J. Mach
Albert J. Mach
SHSoojung Claire Hur
Soojung Claire Hur
HTHenry Tat Kwong Tse
Henry Tat Kwong Tse
DCDino Di Carlo
Dino Di Carlo
Cell separation and sorting are essential steps in cell biology research and in many diagnostic and therapeutic methods. Recently, there has been interest in methods which avoid the use of biochemical labels; numerous intrinsic biomarkers have been explored to identify cells including size, electrical polarizability, and hydrodynamic properties. This review highlights microfluidic techniques used for label-free discrimination and fractionation of cell populations. Microfluidic systems have been adopted to precisely handle single cells and interface with other tools for biochemical analysis. We analyzed many of these techniques, detailing their mode of separation, while concentrating on recent developments and evaluating their prospects for application. Furthermore, this was done from a perspective where inertial effects are considered important and general performance metrics were proposed which would ease comparison of reported technologies. Lastly, we assess the current state of these technologies and suggest directions which may make them more accessible. A wide range of microfluidic technologies have been developed to separate and sort cells by taking advantage of differences in their intrinsic biophysical properties

27 January 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SHSoojung Claire Hur
Soojung Claire Hur
NHNicole K. Henderson-MacLennan
Nicole K. Henderson-MacLennan
EMEdward R. B. McCabe
Edward R. B. McCabe
DCDino Di Carlo
Dino Di Carlo
The ability to detect and isolate rare target cells from heterogeneous samples is in high demand in cell biology research, immunology, tissue engineering and medicine. Techniques allowing label-free cell enrichment or detection are especially important to reduce the complexity and costs towards clinical applications. Single-cell deformability has recently been recognized as a unique label-free biomarker for cell phenotype with implications for assessment of cancer invasiveness. Using a unique combination of fluid dynamic effects in a microfluidic system, we demonstrate high-throughput continuous label-free cell classification and enrichment based on cell size and deformability. The system takes advantage of a balance between deformability-induced and inertial lift forces as cells travel in a microchannel flow. Particles and droplets with varied elasticity and viscosity were found to have separate lateral dynamic equilibrium positions due to this balance of forces. We applied this system to successfully classify various cell types using cell size and deformability as distinguishing markers. Furthermore, using differences in dynamic equilibrium positions, we adapted the system to conduct passive, label-free and continuous cell enrichment based on these markers, enabling off-chip sample collection without significant gene expression changes. The presented method has practical potential for high-throughput deformability measurements and cost-effective cell separation to obtain viable target cells of interest in cancer research, immunology, and regenerative medicine.

2 July 2012 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
KGKeisuke Goda
Keisuke Goda
AAAli Ayazi
Ali Ayazi
DGDaniel R. Gossett
Daniel R. Gossett
JSJagannath Sadasivam
Jagannath Sadasivam
CLCejo K. Lonappan
Cejo K. Lonappan
BJBahram Jalali
Bahram Jalali
Optical microscopy is one of the most widely used diagnostic methods in scientific, industrial, and biomedical applications. However, while useful for detailed examination of a small number (< 10,000) of microscopic entities, conventional optical microscopy is incapable of statistically relevant screening of large populations (> 100,000,000) with high precision due to its low throughput and limited digital memory size. We present an automated flow-through single-particle optical microscope that overcomes this limitation by performing sensitive blur-free image acquisition and nonstop real-time image-recording and classification of microparticles during high-speed flow. This is made possible by integrating ultrafast optical imaging technology, self-focusing microfluidic technology, optoelectronic communication technology, and information technology. To show the system’s utility, we demonstrate high-throughput image-based screening of budding yeast and rare breast cancer cells in blood with an unprecedented throughput of 100,000 particles/s and a record false positive rate of one in a million.

18 December 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SHSoojung Claire Hur
Soojung Claire Hur
HTHenry Tat Kwong Tse
Henry Tat Kwong Tse
DCDino Di Carlo
Dino Di Carlo
Rapid and accurate differentiation of cell types within a heterogeneous solution is a challenging but important task for various applications in biological research and medicine. Flow cytometry is the gold standard in cell analysis and is regularly used for blood analysis (i.e., complete blood counts). Flow cytometry, however, lacks sufficient throughput to analyze rare cells in blood or other dilute solutions in a reasonable time period because it is an inherently serial process. In this study, we exploit inertial effects for label- and sheath-free parallel flow cytometry with extreme throughput. We demonstrate a microfluidic device that consists of 256 high-aspect (W = 16 µm, H = 37 µm) parallel channels yielding a sample rate up to 1 million cells s−1, only limited by the field-of-view of our high-speed optical interrogation method. The particles or cells flowing through the channels are focused to one uniform z-position (SD = ±1.81 µm) with uniform downstream velocity (Uave = 0.208 ± 0.004 m s−1) to reduce the probability of overlap and out-of-focus blur and provide similar cell signature images for accurate detection and analysis. To demonstrate a proof-of-concept application of our system operating at these throughputs, we conducted automated RBC and leukocyte counts on diluted whole blood and achieved high counting sensitivity and specificity (86–97%) compared to visual inspection of raw images. As no additional external forces are required to create ordered streams of cells, this approach has the potential for future applications in cost-effective hematology or rare-cell analysis platforms with extreme throughput capabilities when integrated with suitable large field-of view imaging or interrogation methods.

1 June 2011 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
SHSoojung Claire Hur
Soojung Claire Hur
AMAlbert J. Mach
Albert J. Mach
DCDino Di Carlo
Dino Di Carlo
Cell isolation in designated regions or from heterogeneous samples is often required for many microfluidic cell-based assays. However, current techniques have either limited throughput or are incapable of viable off-chip collection. We present an innovative approach, allowing high-throughput and label-free cell isolation and enrichment from heterogeneous solution using cell size as a biomarker. The approach utilizes the irreversible migration of particles into microscale vortices, developed in parallel expansion-contraction trapping reservoirs, as the cell isolation mechanism. We empirically determined the critical particle/cell diameter Dcrt and the operational flow rate above which trapping of cells/particles in microvortices is initiated. Using this approach we successfully separated larger cancer cells spiked in blood from the smaller blood cells with processing rates as high as 7.5×106 cells/s . Viable long-term culture was established using cells collected off-chip, suggesting that the proposed technique would be useful for clinical and research applications in which in vitro culture is often desired. The presented technology improves on current technology by enriching cells based on size without clogging mechanical filters, employing only a simple single-layered microfluidic device and processing cell solutions at the ml/min scale.

29 July 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
AMAlbert J. Mach
Albert J. Mach
JKJae Hyun Kim
Jae Hyun Kim
AAArmin Arshi
Armin Arshi
SHSoojung Claire Hur
Soojung Claire Hur
DCDino Di Carlo
Dino Di Carlo
The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min−1 scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.