Background: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. Methods: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (7 days) major adverse events. Results: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA 2 DS 2 -VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289–421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%–80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P =0.001). Acute major adverse events occurred in 1.9% of patients. Conclusions: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.
Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0–60) days and 21 (15, 29.5; range: 2–63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0–42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high. Summary of the POTTER-AF study results. CI, confidence interval; OR, odds ratio.
1 January 2022 in Circulation: Arrhythmia and Electrophysiology
Background: Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce. Methods: The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible. Results: A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was −49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months. Conclusions: The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03645577. Graphic A graphic abstract is available for this article.
Aims: Initial clinical studies of pulsed field ablation (PFA) to treat atrial fibrillation (AF) indicated a >90% durability rate of pulmonary vein isolation (PVI). However, these studies were largely conducted in single centres and involved a limited number of operators. We aimed to describe the electrophysiological findings and outcomes in patients undergoing repeat ablation after an initial PF ablation for AF. Methods and results: In the MANIFEST-REDO study, we investigated patients who underwent repeat ablation due to clinical recurrence—AF or atrial tachycardia (AT)—following first-ever PVI with a pentaspline PFA catheter (Farawave, Boston Scientific Inc.). At 22 centres, 427 patients (age 64 ± 11 years; 37% female) were included. Of note, the recurrent arrhythmia leading to the repeat ablation was paroxysmal AF (51%), persistent AF (30%), or AT (19%). At the repeat procedure, the PV reconnection rates were 30% (left superior pulmonary vein), 28% (left inferior pulmonary vein), 33% (right superior pulmonary vein), and 32% (right inferior pulmonary vein). In 45% of patients, all PVs were durably isolated at the beginning of the repeat procedure, with the previous use of any imaging or mapping modality being univariately associated with durable PVI. After a post-redo follow-up period of 284 (90–366) days, the primary effectiveness endpoint (freedom from documented AF/AT lasting ≥30 s after 3-month blanking without class I/III antiarrhythmic drugs or symptoms) was achieved in 65% of patients, with significant differences between groups (PAF 65% vs. PersAF 56% vs. AT 76%; P = 0.04). Persistent AF as recurrent arrhythmia after the initial PFA ablation predicted AT/AF recurrence after repeat ablation [hazard ratio 1.241 (95% confidence interval 1.534–1.005); P = 0.045]. The procedural complication rate was 2.8%. Conclusion: In repeat procedures for AF/AT performed after an index procedure with PFA for AF, PV reconnections are not uncommon. Repeat procedures can be performed safely and with an acceptable subsequent success rate.
Second-generation cryoballoon (CB2)-based pulmonary vein isolation (PVI) has demonstrated encouraging clinical results in the treatment of paroxysmal (PAF) and persistent atrial fibrillation (PersAF). However, the CB2 features a maximal diameter of 28 mm, and its adaptability to anatomic variations of the pulmonary veins (PVs) might be challenging. The purpose of this study was to assess the acute efficacy, safety, and long-term clinical results of CB2-based PVI in patients with a left common pulmonary vein (LCPV). Six hundred seventy consecutive patients underwent CB2-based PVI in 3 electrophysiology centers. In 74 patients (11%), an LCPV was identified (LCPV group). The data were compared to those from matched patients (n = 74) with normal PV anatomy and comparable baseline characteristics (control group). An antral occlusion of the complete LCPV ostium was feasible in 50% of patients in the LCPV group. If an antral occlusion could not be obtained, a sequential isolation of the first superior and inferior branches was applied. All 74 LCPVs were successfully isolated. A total of 64% patients (LCPV group) and 66% patients (control group) remained in sinus rhythm after mean follow-up of 1.9 ± 0.9 years (P = .820). In 18 of 26 patients (69%) with atrial tachyarrhythmia recurrence, a repeat procedure using radiofrequency energy was performed, and a total of 56% LCPVs were found to be persistently isolated (control group: 61% of left-sided PVs, P = .801). Patients with an LCPV undergoing CB2-based PVI demonstrate a high acute success rate. Comparable results with regard to clinical success and durability of PVI were shown when comparing patients of the LCPV group and the control group.
The very high-power short-duration (vHP-SD) radiofrequency (RF) ablation concept of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective, and faster procedures. Utilizing conventional ablation, the ‘close protocol’ has been verified. Since lesion formation of vHP-SD ablation creates wider but shallower lesions we adapted the close protocol to an individualized and tighter ‘very-close protocol’ of 3–4 mm of inter-lesion distance (ILD) at the anterior and 5–6 mm at the posterior aspect of the left atrium using vHP-SD only. Here, we evaluated the safety and efficacy of vHP-SD ablation for PVI utilizing a very-close protocol in comparison with standard ablation. A total of 50 consecutive patients with symptomatic AF were treated with a very-close protocol utilizing vHP-SD (vHP-SD group). The data were compared with 50 consecutive patients treated by the ablation-index-guided strategy (control group). The mean RF time was 352 ± 81 s (vHP-SD) and 1657 ± 570 s (control, P < 0.0001), and the mean procedure duration was 59 ± 13 (vHP-SD) and 101 ± 38 (control, P < 0.0001). The first-pass isolation rate was 74% (vHP-SD) and 76% (control, P = 0.817). Severe adverse events were reported in 1 (2%, vHP-SD) and 3 (6%, control) patients (P = 0.307). A 12-month recurrence-free survival was 78% (vHP-SD) and 64% (control, P = 0.142). PVI durability assessed during redo-procedures was 75% (vHP-SD) vs. 33% (control, P < 0.001). PVI solely utilizing vHP-SD via a very-close protocol provides safe and effective procedures with a high rate of first-pass isolations. The procedure duration and ablation time were remarkably low. A 12-month follow-up and PVI durability are promising.