Sorin Stefan Popescu

Dr. Sorin Stefan Popescu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
Christian-H HeegerChristian-H Heeger
Christian-H Heeger
MSMakoto Sano
Makoto Sano
SPSorin Stefan Popescu
Sorin Stefan Popescu
BSBehnam Subin
Behnam Subin
MFMarcel Feher
Marcel Feher
RTRoland Richard Tilz
Roland Richard Tilz
The very high-power short-duration (vHP-SD) radiofrequency (RF) ablation concept of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective, and faster procedures. Utilizing conventional ablation, the ‘close protocol’ has been verified. Since lesion formation of vHP-SD ablation creates wider but shallower lesions we adapted the close protocol to an individualized and tighter ‘very-close protocol’ of 3–4 mm of inter-lesion distance (ILD) at the anterior and 5–6 mm at the posterior aspect of the left atrium using vHP-SD only. Here, we evaluated the safety and efficacy of vHP-SD ablation for PVI utilizing a very-close protocol in comparison with standard ablation. A total of 50 consecutive patients with symptomatic AF were treated with a very-close protocol utilizing vHP-SD (vHP-SD group). The data were compared with 50 consecutive patients treated by the ablation-index-guided strategy (control group). The mean RF time was 352 ± 81 s (vHP-SD) and 1657 ± 570 s (control, P < 0.0001), and the mean procedure duration was 59 ± 13 (vHP-SD) and 101 ± 38 (control, P < 0.0001). The first-pass isolation rate was 74% (vHP-SD) and 76% (control, P = 0.817). Severe adverse events were reported in 1 (2%, vHP-SD) and 3 (6%, control) patients (P = 0.307). A 12-month recurrence-free survival was 78% (vHP-SD) and 64% (control, P = 0.142). PVI durability assessed during redo-procedures was 75% (vHP-SD) vs. 33% (control, P < 0.001). PVI solely utilizing vHP-SD via a very-close protocol provides safe and effective procedures with a high rate of first-pass isolations. The procedure duration and ablation time were remarkably low. A 12-month follow-up and PVI durability are promising.

22 April 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
RTRoland Richard Tilz
Roland Richard Tilz
MFMarcel Feher
Marcel Feher
JVJulia Vogler
Julia Vogler
KBKerstin Bode
Kerstin Bode
ADAlexandru Ionut Duta
Alexandru Ionut Duta
SPSorin Stefan Popescu
Sorin Stefan Popescu
Aims: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients’ comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. Methods and results: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. Conclusion: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.

2 August 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
Christian-H HeegerChristian-H Heeger
Christian-H Heeger
SPSorin Stefan Popescu
Sorin Stefan Popescu
TITim Inderhees
Tim Inderhees
NNNoemi Nussbickel
Noemi Nussbickel
CECharlotte Eitel
Charlotte Eitel
RTRoland Richard Tilz
Roland Richard Tilz
Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (−56.1 ± 8.3°C) and AF-CB4 (−46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.

7 November 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
Christian-H HeegerChristian-H Heeger
Christian-H Heeger
AAAlexandre Almorad
Alexandre Almorad
USUniv.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Univ.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
NSNándor Szegedi
Nándor Szegedi
SSSebastian Seidl
Sebastian Seidl
RTRoland Richard Tilz
Roland Richard Tilz
Aims: Temperature-controlled high-power short-duration (HPSD) radiofrequency catheter ablation for pulmonary vein isolation (PVI) utilizing a novel ablation catheter (QDOT Micro) with real-time assessment of catheter tip temperature aims for safer, more effective, and faster procedures. Methods and results: The peQasus study is a large European multicentre study set up to assess safety, acute efficacy, and outcomes of temperature-controlled HPSD-based PVI. The primary endpoints were safety, efficacy, and 12-month freedom from atrial tachyarrhythmias. Additionally, two strategies namely very HPSD (90 W for 4 s) only and a hybrid approach (HPSD with maximum of 50 W and vHPSD) were compared. A total of 1023 AF patients in 15 centres from nine European countries received PVI with the QDOT. Complete PVI was successfully achieved in all patients. In 699/1023 (68.3%), the vHPSD-only approach (vHPSD group) and in 324/ (31.7%) patients, the hybrid approach (hybrid group) was utilized. The mean procedure duration was 98.4 ± 37.4 min (vHPSD: 88.2 ± 34.9 min, hybrid: 117.4 ± 32.7 min, P < 0.001). The first-pass isolation rate of all PVs was 64% (vHPSD: 62.6%, hybrid: 67.1%, P = 0.187). Severe adverse events were observed in 1.7% (vHPSD: 1.6%, hybrid: 1.9%, P = 0.746). Twelve-month arrhythmia-recurrence-free survival was 77.1% (vHPSD: 76.8%, hybrid: 77.8%, P = 0.241). Conclusion: In this large multicentre study, temperature-controlled HPSD and vHPSD ablation via a novel ablation catheter provides safe and effective PVI with a relatively short procedure duration. Despite a shorter procedure time, no differences in terms of safety and freedom from arrhythmia recurrence were found irrespective of utilizing vHPSD or the hybrid approach.

23 November 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
Christian-H HeegerChristian-H Heeger
Christian-H Heeger
SPSorin Stefan Popescu
Sorin Stefan Popescu
CSChristian Sohns
Christian Sohns
APAlexander Pott
Alexander Pott
AMAndreas Metzner
Andreas Metzner
RTRoland Richard Tilz
Roland Richard Tilz
Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.

29 September 2024 in Heart Rhythm
Verified
Journal Article
Open access
RTRoland Richard Tilz
Roland Richard Tilz
HPHelmut Pürerfellner
Helmut Pürerfellner
KKKarl-H. Kuck
Karl-H. Kuck
JMJosé L. Merino
José L. Merino
VSVanessa Schmidt
Vanessa Schmidt
SPSorin Stefan Popescu
Sorin Stefan Popescu
The Manufacturer and User Facility Device Experience (MAUDE) database houses medical device reports of adverse events involving medical devices marketed in the United States submitted to the U.S. Food and Drug Administration (FDA) by mandatory and voluntary reporters. The MAUDE database is frequently used in clinical studies to report on device-related complications. Data about its efficacy are scarce. We aimed to compare the mandatory MAUDE database (MAUDE group) with the invitation-based POTTER-AF study (POTTER-AF 1 group) regarding data quality, procedural characteristics, diagnosis, treatment, and survival. The reports of esophageal fistula esophageal fistula following atrial fibrillation (AF) ablation in the MAUDE database were compared with those in the POTTER-AF study between August 1, 2009, and August 31, 2019. Esophageal fistulas were reported in 47 patients in the MAUDE group and in 81 in the POTTER-AF 1 group. Procedures were performed with radiofrequency, cryoenergy, or laser energy in 66.0%, 31.9%, and 2.1% (MAUDE group) and in 96.3%, 2.5%, and 1.2% (POTTER-AF 1 group). The median time to symptoms was 21 (14, 32.5) days (MAUDE group) and 18.0 (6.8, 22.3) days (POTTER-AF 1 group; P = .031). The diagnostic method was reported in 38.3% of patients in the MAUDE group and in 98.8% in the POTTER-AF 1 group, the treatment in 57.4% and 100%, and the outcome in all patients. In the MAUDE group, treatment was surgical (51.9%), endoscopic (37.0%), combined (3.7%), or conservative (7.4%), compared with 43.2%, 19.8%, 7.4%, and 29.6% in the POTTER-AF 1 group. Overall mortality was 76.6% in the MAUDE group and 61.7% in the POTTER-AF 1 group (P = .118). In the mandatory MAUDE database, fewer esophageal fistula cases were reported compared with an invitation-based study. The data quality in the MAUDE database was significantly poorer.