Lawrence Ong

Dr. Lawrence Ong

Science Systems and Applications, Inc., NASA, Greenbelt, MD 20771, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
BMBrian Markham
Brian Markham
JBJulia Barsi
Julia Barsi
GKGeir Kvaran
Geir Kvaran
LOLawrence Ong
Lawrence Ong
EKEdward Kaita
Edward Kaita
DHDennis Helder
Dennis Helder
The Landsat-8 Operational Land Imager (OLI) was radiometrically calibrated prior to launch in terms of spectral radiance, using an integrating sphere source traceable to National Institute of Standards and Technology (NIST) standards of spectral irradiance. It was calibrated on-orbit in terms of reflectance using diffusers characterized prior to launch using NIST traceable standards. The radiance calibration was performed with an uncertainty of ~3%; the reflectance calibration to an uncertainty of ~2%. On-orbit, multiple calibration techniques indicate that the sensor has been stable to better than 0.3% to date, with the exception of the shortest wavelength band, which has degraded about 1.0%. A transfer to orbit experiment conducted using the OLI’s heliostat-illuminated diffuser suggests that some bands increased in sensitivity on transition to orbit by as much as 5%, with an uncertainty of ~2.5%. On-orbit comparisons to other instruments and vicarious calibration techniques show the radiance (without a transfer to orbit adjustment), and reflectance calibrations generally agree with other instruments and ground measurements to within the uncertainties. Calibration coefficients are provided with the data products to convert to either radiance or reflectance units.

17 February 2015 in Remote Sensing
Verified
Journal Article
Open access
PDF file
RMRon Morfitt
Ron Morfitt
JBJulia Barsi
Julia Barsi
RLRaviv Levy
Raviv Levy
BMBrian Markham
Brian Markham
EMEsad Micijevic
Esad Micijevic
KVKelly Vanderwerff
Kelly Vanderwerff
Expectations of the Operational Land Imager (OLI) radiometric performance onboard Landsat-8 have been met or exceeded. The calibration activities that occurred prior to launch provided calibration parameters that enabled ground processing to produce imagery that met most requirements when data were transmitted to the ground. Since launch, calibration updates have improved the image quality even more, so that all requirements are met. These updates range from detector gain coefficients to reduce striping and banding to alignment parameters to improve the geometric accuracy. This paper concentrates on the on-orbit radiometric performance of the OLI, excepting the radiometric calibration performance. Topics discussed in this paper include: signal-to-noise ratios that are an order of magnitude higher than previous Landsat missions; radiometric uniformity that shows little residual banding and striping, and continues to improve; a dynamic range that limits saturation to extremely high radiance levels; extremely stable detectors; slight nonlinearity that is corrected in ground processing; detectors that are stable and 100% operable; and few image artifacts.

1 July 2024 in Aerospace
Verified
Journal Article
Open access
PDF file
DHDavid W. Hughes
David W. Hughes
GCGiuseppe Cataldo
Giuseppe Cataldo
FPFernando A. Pellerano
Fernando A. Pellerano
THTerra C. Hardwick
Terra C. Hardwick
FMFrankie Micalizzi
Frankie Micalizzi
HYHonam Yum
Honam Yum
This paper presents a number of lessons learned while designing a proposed sterilization system for Mars Sample Return. This sterilization system is needed to inactivate any potentially hazardous Mars material on the exterior surface of the vessel containing sealed sample tubes filled with Mars rock cores, regolith and atmosphere. These returned samples would provide information on the geologic history of Mars, the evolution of its climate and the potential for ancient life. Mars Sample Return is categorized at Planetary Protection Category V Restricted Earth Return, so it is required to protect the Earth–Moon system from the biological impact of returning samples from Mars to Earth. This article reviews lessons learned in the development of a particular engineering implementation to support the protection of the Earth–Moon biosphere: the use of in situ ultraviolet LED illumination. The details of the biological efficacy of this approach or the policy-related impacts are outside of the scope of this manuscript. The lessons learned presented here include establishing design requirements for the system, the selection of a light source, optical design options, contamination control and approaches to thermal and power management.

19 August 2010
Verified
Conference Paper
Closed access
PDF file
BJB. Carol Johnson
B. Carol Johnson
RSRobert D. Saunders
Robert D. Saunders
ZLZhigang Li
Zhigang Li
AFAbra Fein
Abra Fein
LOLawrence Ong
Lawrence Ong
BMBrian Markham
Brian Markham
The Landsat Data Continuity Mission (LDCM) project at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) is supervising the manufacture and calibration of the Operational Land Imager (OLI) satellite instrument by Ball Aerospace in Boulder, Colorado. As part of that oversight function, the project is preparing a set of radiometers to monitor long-term changes (if any) in the radiance from the integrating sphere used for the radiance calibration of the OLI instrument. That sphere, calibrated at the National Institute of Standards and Technology (NIST), serves as an artifact for establishing traceability of the OLI radiance calibration to SI units, that is, to the radiance scale at NIST. This paper addresses the characterization of two Analytic Spectral Devices (ASD) Fieldspec spectrometers that are part of the NASA/NIST program to validate radiometric reference standards in the LDCM project. In particular, we report on a series of measurements at NIST to determine the ASD spectrometers' long-term stability. Along with other radiometers, the ASDs will be used in the monitoring of changes in the OLI reference sphere from its calibration at NIST to its use in the calibration of the OLI satellite instrument. The ASD stability measurements will continue through the conclusion of the calibration of OLI.