Julia Barsi

Ms. Julia Barsi


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
JBJulia Barsi
Julia Barsi
JSJohn R. Schott
John R. Schott
SHSimon J. Hook
Simon J. Hook
NRNina G. Raqueno
Nina G. Raqueno
BMBrian Markham
Brian Markham
RRRobert G. Radocinski
Robert G. Radocinski
Launched in February 2013, the Landsat-8 carries on-board the Thermal Infrared Sensor (TIRS), a two-band thermal pushbroom imager, to maintain the thermal imaging capability of the Landsat program. The TIRS bands are centered at roughly 10.9 and 12 μm (Bands 10 and 11 respectively). They have 100 m spatial resolution and image coincidently with the Operational Land Imager (OLI), also on-board Landsat-8. The TIRS instrument has an internal calibration system consisting of a variable temperature blackbody and a special viewport with which it can see deep space; a two point calibration can be performed twice an orbit. Immediately after launch, a rigorous vicarious calibration program was started to validate the absolute calibration of the system. The two vicarious calibration teams, NASA/Jet Propulsion Laboratory (JPL) and the Rochester Institute of Technology (RIT), both make use of buoys deployed on large water bodies as the primary monitoring technique. RIT took advantage of cross-calibration opportunity soon after launch when Landsat-8 and Landsat-7 were imaging the same targets within a few minutes of each other to perform a validation of the absolute calibration. Terra MODIS is also being used for regular monitoring of the TIRS absolute calibration. The buoy initial results showed a large error in both bands, 0.29 and 0.51 W/m2·sr·μm or −2.1 K and −4.4 K at 300 K in Band 10 and 11 respectively, where TIRS data was too hot. A calibration update was recommended for both bands to correct for a bias error and was implemented on 3 February 2014 in the USGS/EROS processing system, but the residual variability is still larger than desired for both bands (0.12 and 0.2 W/m2·sr·μm or 0.87 and 1.67 K at 300 K). Additional work has uncovered the source of the calibration error: out-of-field stray light. While analysis continues to characterize the stray light contribution, the vicarious calibration work proceeds. The additional data have not changed the statistical assessment but indicate that the correction (particularly in band 11) is probably only valid for a subset of data. While the stray light effect is small enough in Band 10 to make the data useful across a wide array of applications, the effect in Band 11 is larger and the vicarious results suggest that Band 11 data should not be used where absolute calibration is required.

23 October 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
JBJulia Barsi
Julia Barsi
KLKenton Lee
Kenton Lee
GKGeir Kvaran
Geir Kvaran
BMBrian Markham
Brian Markham
JPJeffrey A. Pedelty
Jeffrey A. Pedelty
This paper discusses the pre-launch spectral characterization of the Operational Land Imager (OLI) at the component, assembly and instrument levels and relates results of those measurements to artifacts observed in the on-orbit imagery. It concludes that the types of artifacts observed and their magnitudes are consistent with the results of the pre-launch characterizations. The OLI in-band response was characterized both at the integrated instrument level for a sampling of detectors and by an analytical stack-up of component measurements. The out-of-band response was characterized using a combination of Focal Plane Module (FPM) level measurements and optical component level measurements due to better sensitivity. One of the challenges of a pushbroom design is to match the spectral responses for all detectors so that images can be flat-fielded regardless of the spectral nature of the targets in the imagery. Spectral variability can induce striping (detector-to-detector variation), banding (FPM-to-FPM variation) and other artifacts in the final data products. Analyses of the measured spectral response showed that the maximum discontinuity between FPMs due to spectral filter differences is 0.35% for selected targets for all bands except for Cirrus, where there is almost no signal. The average discontinuity between FPMs is 0.12% for the same targets. These results were expected and are in accordance with the OLI requirements. Pre-launch testing identified low levels (within requirements) of spectral crosstalk amongst the three HgCdTe (Cirrus, SWIR1 and SWIR2) bands of the OLI and on-orbit data confirms this crosstalk in the imagery. Further post-launch analyses and simulations revealed that the strongest crosstalk effect is from the SWIR1 band to the Cirrus band; about 0.2% of SWIR1 signal leaks into the Cirrus. Though the total crosstalk signal is only a few counts, it is evident in some scenes when the in-band cirrus signal is very weak. In moist cirrus-free atmospheres and over typical land surfaces, at least 30% of the cirrus signal was due to the SWIR1 band. In the SWIR1 and SWIR2 bands, crosstalk accounts for no more than 0.15% of the total signal.

9 December 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
BMBrian Markham
Brian Markham
JBJulia Barsi
Julia Barsi
GKGeir Kvaran
Geir Kvaran
LOLawrence Ong
Lawrence Ong
EKEdward Kaita
Edward Kaita
DHDennis Helder
Dennis Helder
The Landsat-8 Operational Land Imager (OLI) was radiometrically calibrated prior to launch in terms of spectral radiance, using an integrating sphere source traceable to National Institute of Standards and Technology (NIST) standards of spectral irradiance. It was calibrated on-orbit in terms of reflectance using diffusers characterized prior to launch using NIST traceable standards. The radiance calibration was performed with an uncertainty of ~3%; the reflectance calibration to an uncertainty of ~2%. On-orbit, multiple calibration techniques indicate that the sensor has been stable to better than 0.3% to date, with the exception of the shortest wavelength band, which has degraded about 1.0%. A transfer to orbit experiment conducted using the OLI’s heliostat-illuminated diffuser suggests that some bands increased in sensitivity on transition to orbit by as much as 5%, with an uncertainty of ~2.5%. On-orbit comparisons to other instruments and vicarious calibration techniques show the radiance (without a transfer to orbit adjustment), and reflectance calibrations generally agree with other instruments and ground measurements to within the uncertainties. Calibration coefficients are provided with the data products to convert to either radiance or reflectance units.

17 February 2015 in Remote Sensing
Verified
Journal Article
Open access
PDF file
RMRon Morfitt
Ron Morfitt
JBJulia Barsi
Julia Barsi
RLRaviv Levy
Raviv Levy
BMBrian Markham
Brian Markham
EMEsad Micijevic
Esad Micijevic
KVKelly Vanderwerff
Kelly Vanderwerff
Expectations of the Operational Land Imager (OLI) radiometric performance onboard Landsat-8 have been met or exceeded. The calibration activities that occurred prior to launch provided calibration parameters that enabled ground processing to produce imagery that met most requirements when data were transmitted to the ground. Since launch, calibration updates have improved the image quality even more, so that all requirements are met. These updates range from detector gain coefficients to reduce striping and banding to alignment parameters to improve the geometric accuracy. This paper concentrates on the on-orbit radiometric performance of the OLI, excepting the radiometric calibration performance. Topics discussed in this paper include: signal-to-noise ratios that are an order of magnitude higher than previous Landsat missions; radiometric uniformity that shows little residual banding and striping, and continues to improve; a dynamic range that limits saturation to extremely high radiance levels; extremely stable detectors; slight nonlinearity that is corrected in ground processing; detectors that are stable and 100% operable; and few image artifacts.

1 January 2018 in European Journal of Remote Sensing
Verified
Journal Article
Open access
JBJulia Barsi
Julia Barsi
Bahjat AlhammoudBahjat Alhammoud
Bahjat Alhammoud
JCJeffrey Czapla-Myers
Jeffrey Czapla-Myers
FGFerran Gascon
Ferran Gascon
OHObaidul Haque
Obaidul Haque
BMBrian L. Markham
Brian L. Markham
The Sentinel-2A and Landsat-8 satellites carry on-board moderate resolution multispectral imagers for the purpose of documenting the Earth’s changing surface. Though they are independently built and managed, users will certainly take advantage of the opportunity to have higher temporal coverage by combining the datasets. Thus it is important for the radiometric and geometric calibration of the MultiSpectral Instrument (MSI) and the Operational Land Imager (OLI) to be compatible. Cross-calibration of MSI to OLI has been accomplished using multiple techniques involving the use of pseudo-invariant calibration sites (PICS) using direct comparisons as well as through use of PICS models predicting top-of-atmosphere reflectance. A team from the University of Arizona is acquiring field data under both instruments for vicarious calibration of the sensors. This paper shows that the work done to date by the Landsat and Sentinel-2 calibration teams has resulted in stable radiometric calibration for each instrument and consistency to ~2.5% between the instruments for all the spectral bands that the instruments have in common.

22 August 2018 in Remote Sensing
Verified
Journal Article
Open access
PDF file
DHDennis Helder
Dennis Helder
BMBrian Markham
Brian Markham
RMRon Morfitt
Ron Morfitt
JSJames Storey
James Storey
JBJulia Barsi
Julia Barsi
NPNima Pahlevan
Nima Pahlevan
Combining data from multiple sensors into a single seamless time series, also known as data interoperability, has the potential for unlocking new understanding of how the Earth functions as a system. However, our ability to produce these advanced data sets is hampered by the differences in design and function of the various optical remote-sensing satellite systems. A key factor is the impact that calibration of these instruments has on data interoperability. To address this issue, a workshop with a panel of experts was convened in conjunction with the Pecora 20 conference to focus on data interoperability between Landsat and the Sentinel 2 sensors. Four major areas of recommendation were the outcome of the workshop. The first was to improve communications between satellite agencies and the remote-sensing community. The second was to adopt a collections-based approach to processing the data. As expected, a third recommendation was to improve calibration methodologies in several specific areas. Lastly, and the most ambitious of the four, was to develop a comprehensive process for validating surface reflectance products produced from the data sets. Collectively, these recommendations have significant potential for improving satellite sensor calibration in a focused manner that can directly catalyze efforts to develop data that are closer to being seamlessly interoperable.