The present paper considers some technical issues related to the energy blockchain paradigm applied to microgrids. In particular, what appears from the study is that the superposition of energy transactions in a microgrid creates a variation of the power losses in all the branches of the microgrid. Traditional power losses allocation in distribution systems takes into account only generators while, in this work, a real-time attribution of power losses to each transaction involving one generator and one load node is done by defining some suitable indices. Besides, the presence of P-V nodes increases the level of reactive flows and provides a more complex technical perspective. For this reason, reactive power generation for voltage support at P-V nodes poses a further problem of reactive power flow exchange, that is worth of investigation in future works in order to define a possible way of remuneration. The experimental section of the paper considers a Medium Voltage microgrid and two different operational scenarios.
4 April 2019 in IEEE Transactions on Industry Applications
The energy blockchain is a distributed Internet protocol for energy transactions between nodes of a power system. Recent applications of the energy blockchain in microgrids only consider the energy transactions between peers without considering the technical issues that can arise, especially when the system is islanded. One contribution of the paper is, thus, to depict a comprehensive framework of the technical and economic management of microgrids in the blockchain era, considering, for the first time, the provision of ancillary services and, in particular, of the voltage regulation service. When more PV nodes are operating in the grid, large reactive power flows may appear in the branches. In order to limit such flows, a reactive optimal power flow (R-OPF) is solved, setting the voltage at the PV buses as variables within prescribed limits. Each PV generator will thus contribute to voltage regulation, receiving a remuneration included in the transaction and certified by the blockchain technology. For showing how this system can work, a test microgrid, where some energy transactions take place, has been considered. For each transaction, the R-OPF assigns the reactive power to the PV buses. The R-OPF is solved by a Glow-worm Swarm Optimizer. Finally, the paper proposes a method for remuneration of reactive power provision; this method, integrated into the blockchain, allows evaluating the contribution to voltage regulation and increases the transparency and cost traceability in the transactions. The application section shows the implementation of a Tendermint-based Energy transaction platform integrating R-OPF and the above cited technical assessments.
The occurrence of system separations in the power system of Continental Europe has been observed in recent decades as a critical event which might cause power imbalances higher than the reference incident specified per system design, representing an actual challenge for the stability and safe operation of the system. This work presents an analysis and simulations of the primary frequency control in the Continental Europe synchronous area in conditions of system separation. The adopted approach is based on fundamental aspects of the frequency-containment reserve process. The analysis takes an actual event into consideration, which determined the separation of the system in January 2021. The main purpose of the work is the development of specific models and simulations able to reproduce the actual split event. Due to specific arrangements discussed in detail, it is possible to obtain a substantial match between the simulations and the frequencies registered after the system split. The work also provides insight into the importance of the temporal sequence of power imbalances and defensive actions in the primary frequency control process. The models developed in the work are finally used to investigate the separation event under different operating conditions, such as missing defensive actions and low inertia scenarios.
The operation of a power system with 100% converter-interfaced generation poses several questions and challenges regarding various aspects of the design and the control of the system. Existing literature on the integration of renewable energy sources in isolated systems mainly focuses on energy aspects or steady-state issues, and only a few studies examine the dynamic issues of autonomous networks operated with fully non-synchronous generation. A lack of research can be found in particular in the determination of the required amount of grid-forming power, the selection of the number and rated power of the units which should implement the grid-forming controls, and the relative locations of the grid-forming converters. The paper aims to address those research gaps starting from a theoretical point of view and then by examining the actual electrical network of an existing island as a case study. The results obtained from the investigations indicate specific observations and design opportunities, which are essential for securing the synchronization and the stability of the grid. Possible solutions for a fully non-synchronous operation of autonomous systems, in terms of dynamic characteristics and frequency stability, are presented and discussed.
The present paper deals with the new opportunities deriving from the interconnections of the European and North African transmission systems. In order to achieve a single international market for electricity exchanges, interconnections between networks in different countries are becoming increasingly important and Sicily, for its geographical position in the middle of the Mediterranean Sea, will undoubtedly play an important role as an electrical bridge between Europe and the North Africa in the near future. The paper, presenting the actual electro-energetic context of Tunisia, reports the new important interconnection already realized in South Italy (in particular in Sicily) and describe the planned interventions of the near future. In the second part of the paper, using the Neplan software package (10.7.4, NEPLAN AG, CH-8700 Küsnacht (ZH), Switzerland) for simulating the grid, some load flows are carried out to check some operating scenarios (2020 and 2025) considering energy flows from north to south, avoiding system violations.
This article addresses the question if it is cost-effective to use medium-scale battery storage systems for time-of-use (TMO) energy cost applications at a consumer level, assuming flexible electricity tariffs in the Italian electricity market. TMO application allows customers to reduce their electricity bill charging the storage when off-peak time periods are applied and discharge it during on-peak periods, when electricity energy prices are high. The analysis is carried out taking into account three different electrochemical storage technologies. The economical comparison shows that, at the current costs of storage technologies and at the electricity tariffs currently offered in Italy, the use of battery systems for TMO energy cost applications is not economically advantageous for a medium-scale public institution facility. However, the aggregation of different benefits for the same storage technology, such as voltage support, deferral of investment in T&D network upgrades, reducing T&D losses and so on could modify this assumption.