yidong Chen

Mr. yidong Chen

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2023 in Materials
Verified
Journal Article
Open access
PDF file
YWYujing Wang
Yujing Wang
JXJunwu Xia
Junwu Xia
PLPengxu Li
Pengxu Li
LYLinli Yu
Linli Yu
HYHan Yang
Han Yang
YCyidong Chen
yidong Chen
To assess the freeze–thaw (F-T) durability of coal gangue pervious concrete (CGPC) in different F-T cycle media (water, 3.5 wt% NaCl solution), experimental studies on 36 groups of cube specimens and 6 groups of prismatic specimens were carried out, with designed porosity, F-T cycling media, and F-T failure times as variables. The changes in apparent morphology, mass, compressive behavior, relative dynamic elastic modulus, and permeability coefficient have been analyzed in detail. To predict the compressive strength after F-T cycles, a GM (1,1) model based on the grey system theory was developed and further improved into a more accurate grey residual–Markov model. The results reported that the cement slurry and coal gangue aggregates (CGAs) on the specimen surface continued to fall off as F-T cycles increased, and, finally, the weak point was fractured. Meanwhile, the decrease in compressive behavior and relative dynamic elastic modulus was gentle in the early phase of F-T cycles, and they gradually became faster in the later stage, showing a parabolic downward trend. The permeability coefficient increased gradually. When F-T failure occurred, specimen mass dropped precipitously. The F-T failure of CGPC was more likely to occur in 3.5 wt% NaCl solution, and the F-T failure times of samples were 25 times earlier than that of water. This study lays the foundation for an engineering application and provides a basis for the large-scale utilization of CGPC.

8 September 2024 in Forests
Verified
Journal Article
Open access
PDF file
YCyidong Chen
yidong Chen
LXLinrong Xie
Linrong Xie
XLXinyu Liu
Xinyu Liu
YQYI QI
YI QI
XJXiang Ji
Xiang Ji
This research proposes an optimized method for identifying high-quality vegetation areas, with a focus on forest ecosystems, using an improved Vegetation Health Index (VHI). The study introduces the Land Cover Vegetation Health Index (LCVHI), which integrates the Vegetation Condition Index (VCI) and the Temperature Condition Index (TCI) with land cover data. Utilizing MODIS (Moderate Resolution Imaging Spectroradiometer) satellite imagery and Google Earth Engine (GEE), the study assesses the impact of land cover changes on vegetation health, with particular attention to forested areas. The application of the LCVHI demonstrates that forests exhibit a VHI approximately 25% higher than that of croplands, and wetlands show an 18% higher index compared to grasslands. Analysis of data from 2012 to 2022 in Hubei Province, China, reveals an overall upward trend in vegetation health, highlighting the effectiveness of environmental protection and forest management measures. Different land cover types, including forests, wetlands, and grasslands, significantly impact vegetation health, with forests and wetlands contributing most positively. These findings provide important scientific evidence for regional and global ecological management strategies, supporting the development of forest conservation policies and sustainable land use practices. The research results offer valuable insights into the effective management of regional ecological dynamics.

2 June 2025 in Buildings
Verified
Journal Article
Open access
PDF file
XLXinyu Liu
Xinyu Liu
BSBo Sun
Bo Sun
XJXiang Ji
Xiang Ji
CHChen Hua
Chen Hua
YCyidong Chen
yidong Chen
HZhong Zhang
hong Zhang
The rapid development of urban subway network is prompting higher requirements for daylighting in subway stations. The skylight daylighting space of shallow buried subway stations not only improves the quality of light environment but also brings challenges for the optimization of light and thermal performance, especially in areas with hot summers and cold winters. In this paper, key parameters such as illumination, air temperature, and the black sphere temperature of skylight and artificial lighting areas at stations A and B in Shanghai were tested with a field test system. The results show that the light environment in the skylight areas was significantly improved, but the need for regulation and control of the thermal environment increased. Combined with response surface analysis, 10 sample models for two types of daylighting space (partitioned and open atrium styles) were studied and constructed, including 254 simulated working conditions. The results reveal that design parameters such as the number, aspect ratio, depth of light openings, and skylight angle have significant effects on combined energy consumption. The decentralized double slope roof daylighting space has the best performance in partitioned and open atrium-style public areas, and combined energy consumption can be reduced to 385.14 kWh/m2. The optimization strategies proposed in this study can provide a quantitative basis for the skylight design of shallow buried subway stations and an important reference for the design of low-carbon and energy-saving underground spaces.

12 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
XLXinyu Liu
Xinyu Liu
BSBo Sun
Bo Sun
XJXiang Ji
Xiang Ji
CHChen Hua
Chen Hua
YCyidong Chen
yidong Chen
HZhong Zhang
hong Zhang
The rapid development of urban subway network puts forward higher requirements for daylighting in subway stations. The skylight daylighting space of shallow buried subway stations not only improves the quality of light environment, but also brings challenges for the optimization of light and thermal performance especially in areas with hot summer and cold winter. In this paper, key parameters such as illumination, air temperature and black sphere temperature of skylight and artificial lighting areas at stations A and B in Shanghai were tested with a field test system. The results show that the light environment in the skylight areas was significantly improved, but the need for the regulation and control of thermal environment was increased. Combined with response surface analysis, 10 sample models for two types of daylighting space (partitioned and through-atrium types) were studied and constructed, including 254 simulated working conditions. The results reveal that design parameters such as the number, aspect ratio, and depth of light openings, and skylight angle have significant effects on combined energy consumption. The decentralized double slope roof daylighting space has the best performance in the partitioned and through-atrium public areas, and combined energy consumption can be reduced to 385.14 kWh/㎡. The optimization strategies proposed in this study can provide a quantitative basis for the skylight design of shallow buried subway stations and an important reference for the design of low-carbon and energy-saving underground space.