Mohamed Khaled Addas

Prof. Mohamed Khaled Addas

King Khalid University, Abhā, ‘Asīr, Saudi Arabia
+1
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2023 in Polymers
Verified
Journal Article
Open access
PDF file
SVSunil Vaddamanu
Sunil Vaddamanu
FAFahad Hussain AlHamoudi
Fahad Hussain AlHamoudi
SCsaurabh chaturvedi
saurabh chaturvedi
NANasser M. Alqahtani
Nasser M. Alqahtani
MAMohamed Khaled Addas
Mohamed Khaled Addas
AEAsim Elsir Elmahdi
Asim Elsir Elmahdi
Background: Polyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability, especially towards the retentive forces and deformation of the clasp. This study aimed to examine the retentive forces and the fitting surface (inner surface) deformation of clasps made from PEEK and compare it with cobalt–chromium (Co-Cr) clasp. Methods: Forty-two circumferential clasps (14 Co-Cr and 28 PEEK) were fabricated and divided into two groups with clasp undercuts (0.25 mm and 0.5 mm) with thicknesses of 1 mm and 1.5 mm. Each was examined for retentive forces after cycle test on its abutment for 360 cycles. Initial and final retentive forces were recorded. The fitting surface deformation was determined using 3-Matic research analysis software. Results: The results revealed that highest mean initial retentive force was of Co-Cr clasps with 0.50 mm undercut 22.26 N (±10.15 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 3.35 N (±0.72 N) and highest mean final retentive force was the Co-Cr clasps with 0.50 mm undercut 21.40 N (±9.66 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 2.71 N (±0.47 N). PEEK clasps had a lower retentive force than Co-Cr clasps with 0.50 undercut. PEEK clasps (1.5 mm) at 0.25 mm undercut had the least deformation (35.3 µm). PEEK showed significantly less deformation (p ≤ 0.014) than Co-Cr. Conclusion: The deformation of PEEK clasps fitting surface was lower than Co-Cr clasps and retentive forces were close to the Co-Cr clasps, suggesting the use of PEEK as an aesthetic clasp option for RPD framework.

29 August 2017 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
SCsaurabh chaturvedi
saurabh chaturvedi
MAMohamed Khaled Addas
Mohamed Khaled Addas
AHAbdullah Saad Ali Al Humaidi
Abdullah Saad Ali Al Humaidi
AQAbdulrazaq Mohammed Al Qahtani
Abdulrazaq Mohammed Al Qahtani
MQMubarak Daghash Al Qahtani
Mubarak Daghash Al Qahtani
Aim. To determine the prevalence of type of soft palate in targeted population. Materials and Methods. Using computer technology in dentistry, intraoral digital scanner, and 3D analysis software tool, study was conducted. 100 patients selected from the outpatient clinics were divided into two groups based on the ages of 20–40 years and 41–60 years with equal ratio of males and females. Each selected patient’s maxillary arch was scanned with intraoral scanner; images so obtained were sectioned in anteroposterior cross section and with the 3D analysis software; the angulation between hard and soft palate was determined. Results. The prevalence of type II soft palate (angulation between hard and soft palate is between 10 and 45 degrees) was highest, 60% in group 1 and 44% in group 2. The difference between genders was statistically significant with p value <0.05 in both the groups, although females had higher angulation compared to the males in all classes of both groups. Conclusions. In targeted population of Aseer Province, Saudi Arabia, the prevalence of type II soft palate was more common, with higher soft palate angulation among females. The advanced age had no effect in the type of soft palate in the region.

1 February 2023 in Polymers
Verified
Journal Article
Open access
PDF file
SMSwati Mishra
Swati Mishra
SCsaurabh chaturvedi
saurabh chaturvedi
MAMariyam Ali
Mariyam Ali
KPKaushik Kumar Pandey
Kaushik Kumar Pandey
NANasser M. Alqahtani
Nasser M. Alqahtani
WAWaleed M S Alqahtani
Waleed M S Alqahtani
An accurate and dimensionally stable trial denture base is required for a successful denture. The aim of this in vitro study was to assess the dimensional stability of a light-activated urethane dimethacrylate (UDMA) visible light cure (VLC) denture base with three fabrication techniques and different curing cycles. Forty-five VLC denture base samples were divided evenly into three groups. Group A used a conventional fabrication technique with a curing cycle of 5 min. Group B used a modified fabrication technique with two 4-min curing cycles. Group C used a multi-step fabrication technique with three curing cycles (4 min, plus 4 min, plus 2 min). The samples were sectioned and observed under a stereomicroscope to measure the discrepancy between the sample and the master cast. The mean dimensional discrepancy (mm) at the molar region at mid-palate, after 24 h in Group A, B and C was 0.790 mm, 0.741 mm and 0.379 mm, respectively; at the right ridge crest, it was 0.567, 0.408 and 0.185, while at the left ridge crest it was 0.475, 0.331 and 0.125, respectively. Statistical analysis showed significantly different dimensional discrepancies among the groups at all three sites; right ridge crest (F = 93.54, p < 0.001), left ridge crest (F = 105.96, p < 0.001) and mid-palate (F = 125.53, p < 0.001). Within the limitations of this laboratory study, it can be concluded that the denture base using a multi-step fabrication technique with three curing cycles provides better adaptation than the conventional technique. The significance of the study is that clinicians should consider performing denture base fabrication using a multi-step technique to enhance adaptation and hence the stability of the dentures for patients.

16 September 2022 in Medicine
Verified
Journal Article
Open access
MAMohammed Alobaid
Mohammed Alobaid
EAEbtihal M. Bds Alshahrani
Ebtihal M. Bds Alshahrani
EAEbtsam M. Bds Alshehri
Ebtsam M. Bds Alshehri
ASAmal S Shaiban
Amal S Shaiban
SHSatheesh Haralur
Satheesh Haralur
MAMohamed Khaled Addas
Mohamed Khaled Addas
Lack of basic knowledge about the external and internal anatomies of the root canal system and common variations in teeth may lead to various procedural errors or treatment failure. In this study, the root canal configurations of mandibular incisors and the symmetry of the contralateral incisors of Saudi Arabian subpopulations were analyzed and determined using cone beam computed tomography (CBCT). A retrospective evaluation of 700 patients was conducted, and 1260 fully developed permanent mandibular central incisors were assessed. The number of root canals was determined, and the internal root canal anatomies were categorized based on Ahmed et al.’s criteria. The CBCT images were independently evaluated by 2 trained dentists and an endodontist. The data were assessed using the chi-square and one-way analysis of variance tests. All the mandibular central incisors included in the study were single-rooted. According to Ahmed et al’s classification system, the most common classification (82.6%) was 1ManA1 (Vertucci type I), followed by 1ManA1-2-1 (Vertucci type III; 13%). Second canals were more frequently recorded in the male participants than in the female participants. The root canal configuration between contralateral incisors was largely symmetrical. Most of the mandibular incisors in the examined Saudi Arabian population had a single canal. Nevertheless, a substantial number of patients had a complex root morphology. Hence, CBCT can be utilized as a potential supplementary tool during root canal treatment.

27 June 2022 in Polymers
Verified
Journal Article
Open access
PDF file
AMAmina
Amina
GRGeeta Rajput
Geeta Rajput
SASaad Ahmed
Saad Ahmed
SCsaurabh chaturvedi
saurabh chaturvedi
MAMohamed Khaled Addas
Mohamed Khaled Addas
KGKanishk Gupta
Kanishk Gupta
Microleakage is a persistent problem despite advancement in materials and techniques in fixed prosthodontics. This leads to the importance of sound crown foundation material and luting agents used to maintain the marginal seal. The literature is deficient with studies, comparing microleakage under various crown foundation materials and luting agents, especially with CAD-CAM (computer-aided design and computer-aided manufacturing) metal crowns. This study was aimed to compare microleakage in a nanocomposite/dentinal bonding agent and amalgam/cavity varnish as crown foundation materials luted with two different luting cements: resin-reinforced glass ionomer cement and self-adhesive resin cement, under both dry and contaminated conditions. A hundred intact, caries-free human molars were prepared to receive crown foundation material and extra coronal restorations. Amalgams with cavity varnish and nanocomposites with dentinal bonding agent in both ideal and contaminated conditions were used as crown foundation materials. After restoration, each sample was cemented with a CAD-CAM milled metal crown using two different luting agents—resin-reinforced glass ionomer cement and self-adhesive resin cements both in ideal and contaminated conditions. Cementation was followed by thermocycling of samples, immersion in erythrosine B dye, embedding in clear auto polymerizing acrylic resin and sectioning to evaluate microleakage using stereomicroscope. The mean microleakage between different luting cements on the experimental side of the facial surface was 137.64 μm and 211.01 μm for resin-reinforced GIC and for self-adhesive resin cement was 119.78 μm and 150.42 μm, under ideal and contaminated condition, respectively. There was a significant difference in mean micro-leakage between different crown foundation material and cement groups used in the study. The composites and amalgam, both when used as crown foundation material and luted with use of technically advanced CAD-CAM metal crown with self-adhesive resin cement (in both ideal or contaminated condition), showed less microleakage than in resin-reinforced glass ionomer cement. Overall, the self-adhesive resin cement showed comparatively reduced microleakage in all combinations with different crown foundations. Thus, this combination can be used in daily clinical practice to provide better protection from further decay.

1 June 2014
Verified
Journal Article
Closed access
SHSatheesh Haralur
Satheesh Haralur
MAMohamed Khaled Addas
Mohamed Khaled Addas
HOHesham I Othman
Hesham I Othman
FSFarhan K Shah
Farhan K Shah
AEAbdullah Idrees El-Malki
Abdullah Idrees El-Malki
MAMohammed Abdullah Al-Qahtani
Mohammed Abdullah Al-Qahtani