Fahad Hussain AlHamoudi

Dr. Fahad Hussain AlHamoudi

King Khalid University, Abhā, ‘Asīr, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
LRLingala Reddy
Lingala Reddy
PMPallavi Madithati
Pallavi Madithati
BNBayapa Reddy Narapureddy
Bayapa Reddy Narapureddy
SRSahithya Ravali Ravula
Sahithya Ravali Ravula
SVSunil Vaddamanu
Sunil Vaddamanu
SCsaurabh chaturvedi
saurabh chaturvedi
Background: The use of health applications (apps) in smartphones increased exponentially during COVID-19. This study was conducted the with the aim to understand the factors that determine the consumer’s perception of health apps in smartphones towards telemedicine during COVID-19 and to test any relation between these factors and consumers towards Telemedicine in India. Methods: This questionnaire-based cross-sectional study was conducted from July 2021 to December 2021 in India. Out of 600 selected participants, 594 responded and in that 535 valid questionnaires were measured. The questionnaire consists of close-ended responses, with the first part consisting of demographic information, the second part consisting of questions associated with consumers’ perceptions and the third part kept for suggestions and complaints. The questionnaire was distributed using digital platforms via WhatsApp or email. A 5-point Likert scale, ranging from strongly agree’ (5) to strongly disagree (1) was used to record responses. Results: Results revealed a high response rate of 90%. The highest score was obtained for the question assessing the satisfaction of the users towards health apps [1175 = 500 (agree-4) + 675 (Strongly agree-5)]. The interface of the app scored very low, showing disagreement (514) with app functionality, and was the most common disadvantage as perceived by patients. The mean scores of reliabilities and vicinity of health services; efficacy and comprehensive health information; development and improvement of health apps and telemedicine (3.24, 3.18, 3.62, 3.49), respectively, show the difference in attraction existing between groups. There is a strong positive correlation between the variables except for efficacy and comprehensive information about health and Telemedicine (−0.249), development and improvement of health apps, and reliability and vicinity of health services (−0.344) which have a negative correlation. Conclusions: The findings of this survey reveal a positive outlook of health apps toward telemedicine. This research also found a strong forecaster of the consumer’s perception of health apps in smartphones towards telemedicine. In the broad spectrum, the future of health app affiliates for telemedicine is better affected by the consumer’s perception of health app efficacy. This study suggests that health app marketers develop more innovative apps to increase usage and help consumers.

1 February 2023 in Children
Verified
Journal Article
Open access
PDF file
KKKANWALPREET KAUR
KANWALPREET KAUR
BSBharat Suneja
Bharat Suneja
SJSunaina Jodhka
Sunaina Jodhka
RSRavinder S Singh
Ravinder S Singh
SCsaurabh chaturvedi
saurabh chaturvedi
Giuseppe MinerviniGiuseppe Minervini
Giuseppe Minervini
Aim: To evaluate and compare the clinical outcomes of Cention-N (CN) and stainless steel crowns (SSCs) as restorations for pulpotomised primary molars, and to study clinical and radiographic outcomes of pulpotomies restored with these materials. Methods: The study was conducted on 60 pulpotomised molars with occlusoproximal caries. These were randomly divided into two groups and restored with either stainless steel crowns or Cention-N. Clinical performance of restorations and clinical and radiographic success of pulpotomy was examined at 6, 9 and 12 months. Results: The mean scores for marginal integrity deteriorated significantly at 6, 9 and 12 months in both groups but in comparison were insignificant. The mean for proximal contact deteriorated significantly for the Cention-N group, whereas the mean for gingival health deteriorated remarkably for the stainless steel crown group at successive evaluations. No tooth in either group showed secondary caries or discomfort on biting, except for one tooth in Cention-N group which presented with secondary caries. The clinical success rate for pulpotomised molars was 100% for both groups until nine months, although this had reduced by the end of 12 months. Radiographically, the success rate was 79.3% for Cention-N, while it was 86.6% for stainless steel crowns at 12 months. There was no significant difference in clinical and radiographic success between either group. Conclusion: Cention-N and stainless steel crowns are comparable for marginal integrity. However, crowns maintain significantly better proximal contacts while Cention-N was notably better for gingival health of the restored tooth. Both materials do not show secondary caries and discomfort on biting and are comparable in clinical and radiographic success of pulpotomy at the end of one year.

Verified
Journal Article
Open access
PDF file
MKMohammad Jamal Khan
Mohammad Jamal Khan
LRLingala Reddy
Lingala Reddy
JKJaved Khan
Javed Khan
BNBayapa Reddy Narapureddy
Bayapa Reddy Narapureddy
SVSunil Vaddamanu
Sunil Vaddamanu
SCsaurabh chaturvedi
saurabh chaturvedi
The COVID-19 crisis demanded that all educational activities should be performed virtually to follow social distancing guidelines. Therefore, there was a need to perform a research study to assess the effects of external factors on the perceived usefulness, ease of use of e-learning, and the further effect of these perceptions on attitude and intent to use e-learning by using the technology acceptance model (TAM) among academicians at higher education institutions in the Kingdom of Saudi Arabia. Methods: A cross-sectional study was conducted, and data were collected from 263 academicians across Saudi Arabia through an online survey questionnaire using a non-probability purposive sampling technique and analyzed and tested using the SPSS and Smart PLS software. Results: This study found that self-efficacy was positively associated with perceived usefulness at β = 0.143 and p < 0.05, but it had no association with perceived ease of use at β = 0.057 at p > 0.05. System accessibility had a significant and positive relationship with perceived usefulness and perceived ease of use at β = 0.283, β = 0.247, and p < 0.01, respectively. Self-efficacy had a positive effect on perceived usefulness, whereas the subjective norm had no relationship with perceived usefulness and perceived ease of use at β = −0.065 and β = −0.012 at p > 0.05, respectively. Perceived ease of use and perceived usefulness were positively related to attitude towards use, which has a significant influence on intention to use e-learning. Conclusion: Perceived ease of application is the most significant factor (β = 0.556) in developing the attitude among academicians to practice e-learning, followed by perceived usefulness (β = 0.262). Moreover, it can be concluded that system accessibility has a stronger influence on developing perception among academicians about the expediency and ease of application of e-learning than self-efficacy.

3 April 2024 in Heliyon
Verified
Journal Article
Open access
HAHafsah Akhtar
Hafsah Akhtar
FAFahad Hussain AlHamoudi
Fahad Hussain AlHamoudi
JMJulie Marshall
Julie Marshall
TAThomas Ashton
Thomas Ashton
JDJawwad A. Darr
Jawwad A. Darr
Gwendolen ReillyGwendolen Reilly
Gwendolen Reilly
A novel eco-friendly high throughput continuous hydrothermal flow system was used to synthesise phase pure ZnO and doped ZnO in order to explore their properties for tissue engineering applications. Cerium, zirconium, and copper were introduced as dopants during flow synthesis of ZnO nanoparticles, Zirconium doped ZnO were successfully synthesised, however secondary phases of CeO and CuO were detected in X-ray diffraction (XRD). The nanoparticles were characterised using X-ray diffraction, Brunauer-Emmett-Teller (BET), Dynamic Light scattering Measurements, Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR) and RAMAN spectroscopy was used to evaluate physical, chemical, and structural properties. The change in BET surface area was also significant, the surface area increased from 11.35 (ZnO_2) to 26.18 (ZrZnO_5). However. In case of CeZnO_5 and CuZnO_5 was not significant 13.68 (CeZnO_5) and 12.16 (CuZnO_5) respectively. Cell metabolic activity analysis using osteoblast-like cells (MG63) and human embryonic derived mesenchymal stem cells (hES-MP) demonstrated that doped ZnO nanoparticles supported higher cell metabolic activity compared to cells grown in standard media with no nanoparticles added, or pure zinc oxide nanoparticles. The ZrZnO_5 demonstrated the highest cell metabolic activity and non-cytotoxicity over the duration of 28 days as compared to un doped or Ce or Cu incorporated nanoparticles. The current data suggests that Zirconium doping positively enhances the properties of ZnO nanoparticles by increasing the surface area and cell proliferation. Therefore, are potential additives within biomaterials or for tissue engineering applications.

15 February 2023 in Polymers
Verified
Journal Article
Open access
PDF file
SVSunil Vaddamanu
Sunil Vaddamanu
FAFahad Hussain AlHamoudi
Fahad Hussain AlHamoudi
SCsaurabh chaturvedi
saurabh chaturvedi
NANasser M. Alqahtani
Nasser M. Alqahtani
MAMohamed Khaled Addas
Mohamed Khaled Addas
AEAsim Elsir Elmahdi
Asim Elsir Elmahdi
Background: Polyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability, especially towards the retentive forces and deformation of the clasp. This study aimed to examine the retentive forces and the fitting surface (inner surface) deformation of clasps made from PEEK and compare it with cobalt–chromium (Co-Cr) clasp. Methods: Forty-two circumferential clasps (14 Co-Cr and 28 PEEK) were fabricated and divided into two groups with clasp undercuts (0.25 mm and 0.5 mm) with thicknesses of 1 mm and 1.5 mm. Each was examined for retentive forces after cycle test on its abutment for 360 cycles. Initial and final retentive forces were recorded. The fitting surface deformation was determined using 3-Matic research analysis software. Results: The results revealed that highest mean initial retentive force was of Co-Cr clasps with 0.50 mm undercut 22.26 N (±10.15 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 3.35 N (±0.72 N) and highest mean final retentive force was the Co-Cr clasps with 0.50 mm undercut 21.40 N (±9.66 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 2.71 N (±0.47 N). PEEK clasps had a lower retentive force than Co-Cr clasps with 0.50 undercut. PEEK clasps (1.5 mm) at 0.25 mm undercut had the least deformation (35.3 µm). PEEK showed significantly less deformation (p ≤ 0.014) than Co-Cr. Conclusion: The deformation of PEEK clasps fitting surface was lower than Co-Cr clasps and retentive forces were close to the Co-Cr clasps, suggesting the use of PEEK as an aesthetic clasp option for RPD framework.

Verified
Journal Article
Open access
PDF file
FAFahad Hussain AlHamoudi
Fahad Hussain AlHamoudi
HRHamza U Rehman
Hamza U Rehman
YAYasser Ali Almoshawah
Yasser Ali Almoshawah
ATAbdullah C. S. Talari
Abdullah C. S. Talari
ACAqif Anwar Chaudhry
Aqif Anwar Chaudhry
Ihtesham RehmanIhtesham Rehman
Ihtesham Rehman
In the maxillofacial area, specifically the orbital floor, injuries can cause bone deformities in the head and face that are difficult to repair or regenerate. Treatment methodologies include use of polymers, metal, ceramics on their own and in combinations mainly for repair purposes, but little attention has been paid to identify suitable materials for orbital floor regeneration. Polyurethane (PU) and hydroxyapatite (HA) micro- or nano- sized with different percentages (25%, 40% & 60%) were used to fabricate bioactive tissue engineering (TE) scaffolds using solvent casting and particulate leaching methods. Mechanical and physical characterisation of TE scaffolds was investigated by tensile tests and SEM respectively. Chemical and structural properties of PU and PU/HA scaffolds were evaluated by infrared (IR) spectroscopy and Surface properties of the bioactive scaffold were analysed using attenuated total reflectance (ATR) sampling accessory coupled with IR. Cell viability, collagen formed, VEGF protein amount and vascularisation of bioactive TE scaffold were studied. IR characterisation confirmed the integration of HA in composite scaffolds, while ATR confirmed the significant amount of HA present at the top surface of the scaffold, which was a primary objective. The SEM images confirmed the pores’ interconnectivity. Increasing the content of HA up to 40% led to an improvement in mechanical properties, and the incorporation of nano-HA was more promising than that of micro-HA. Cell viability assays (using MG63) confirmed biocompatibility and CAM assays confirmed vascularization, demonstrating that HA enhances vascularization. These properties make the resulting biomaterials very useful for orbital floor repair and regeneration.
1