James Bull

Mr. James Bull


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
JBJames Bull
James Bull
James M. BuickJames M. Buick
James M. Buick
JRJovana Radulovic
Jovana Radulovic
Approximately 45% of power generated by conventional power systems is wasted due to power conversion process limitations. Waste heat recovery can be achieved in an Organic Rankine Cycle (ORC) by converting low temperature waste heat into useful energy, at relatively low-pressure operating conditions. The ORC system considered in this study utilises R-1234yf as the working fluid; the work output and thermal efficiency were evaluated for several operational pressures. Plate and shell and tube heat exchangers were analysed for the three sections: preheater, evaporator and superheater for the hot side; and precooler and condenser for the cold side. Each heat exchanger section was sized using the appropriate correlation equations for single-phase and two-phase fluid models. The overall heat exchanger size was evaluated for optimal operational conditions. It was found that the plate heat exchanger out-performed the shell and tube in regard to the overall heat transfer coefficient and area.

5 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
CCCameron Campbell-Stanway
Cameron Campbell-Stanway
Victor BecerraVictor Becerra
Victor Becerra
SPShanker Prabhu
Shanker Prabhu
JBJames Bull
James Bull
Water electrolysis for hydrogen production with renewable electricity is regularly studied as an option for decarbonised future energy scenarios. The inclusion of byproduct electrolytic oxygen capture and sale is of interest for parallel decarbonisation efforts elsewhere in the industry and could contribute to reducing green hydrogen costs. A deterministic hydrogen electrolysis system model is constructed to compare oxygen inclusion/exclusion scenarios. This uses wind and solar-PV electricity generation timeseries, a power-dependent electrolysis model to determine the energy efficiency of gas yield, and power allocation for gas post-processing energy within each hourly timestep. This maintains a fully renewable (and therefore low/zero carbon) electricity source for electrolysis and gas post-processing. The model is validated (excluding oxygen) against an existing low-cost GW-scale solar-hydrogen production scenario and an existing hydrogen production costs study with offshore wind generation at the multi-MW scale. For both comparisons, oxygen inclusion is then evaluated to demonstrate both the benefits and drawbacks of capture and utilisation, for different scenario conditions, and high parameter sensitivity can be seen regarding the price of renewable electricity. This work subsequently proposes that the option for the potential utilisation of byproduct oxygen should be included in future research to exemplify otherwise missed benefits.

4 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
JBJames Bull
James Bull
JPJed Pound
Jed Pound
JRJovana Radulovic
Jovana Radulovic
James M. BuickJames M. Buick
James M. Buick
The International Energy Agency states that geothermal energy technologies could meet 15% of the global electricity demand growth, provided cost reductions continue. Organic Rankine Cycle (ORC) systems are expected to play a key role in achieving this ambitious target. Recognized for their effectiveness in converting low-to-moderate temperature heat, ORC systems are already in use in numerous installations. The performance of ORC systems is primarily influenced by operational conditions and the choice of working fluid. A key system design challenge arises from the operational conditions of ORC systems, which are closely tied to the design and sizing of heat exchange components. This study examines the effect of the pinch point temperature difference, and the approach point temperature on the thermodynamic performance of a low-temperature ORC, with cycle efficiency and the total heat transfer area of the evaporator serving as the main performance indicators. The analysis uses a parametric approach to assess ORC performance by varying pinch point and approach point temperatures for a range of suitable working fluids. An optimal design region is identified, where the trade-off between thermal efficiency and heat exchanger size is most advantageous. These results offer valuable theoretical insights for low-temperature ORC design, highlighting the importance of selecting pinch point and approach point temperatures that strike a balance between thermal and economic goals.

8 July 2025 in Machines
Verified
Journal Article
Open access
PDF file
JDJordan Dickenson
Jordan Dickenson
James M. BuickJames M. Buick
James M. Buick
JRJovana Radulovic
Jovana Radulovic
JBJames Bull
James Bull
Model validation is an essential part of CFD-based projects. Despite being successfully employed for decades, the level and extent of CFD model validation details vary significantly in the published literature, which, in turn, adversely affects the repeatability and usefulness of published models and data. This study explores the various challenges associated with validating CFD models of thermodynamic components, namely, the compressors and their performance evaluation. The methodology involves blade generation through TurboGrid and BladeGen, mesh generation to ensure computational efficiency, and pre-processing with CFX to define boundary conditions and turbulence models, all within ANSYS 2024 R1. Three case studies are discussed, each assessing different compressor configurations and common challenges encountered during the model validation stage. Based on the case studies, a number of recommendations are presented relating to best practices in terms of both the use of published materials to validate new models and the level of detail required for experimental or simulation publication to ensure they can be replicated or used to validate a new model.

27 July 2026 in Processes
Verified
Journal Article
Open access
PDF file
JDJordan Dickenson
Jordan Dickenson
JBJames Bull
James Bull
JRJovana Radulovic
Jovana Radulovic
James M. BuickJames M. Buick
James M. Buick
The phasing out of high-GWP refrigerants and the growing diversity of working fluids used across heat pumps, refrigeration systems, and closed-cycle power applications have made drop-in fluid replacement a question of significant practical interest. Centrifugal compressors are designed around the thermophysical properties of a specific fluid, and the performance penalty is incurred when working fluid is replaced without redesigning the impeller. This study presents a CFD comparison of direct drop-in fluid replacement in a fixed geometry centrifugal compression system. Eight working fluids that span the property range relevant to current drop-in substitutions are evaluated: air, nitrogen, argon, carbon dioxide, R22, R134a, R1234yf, and R1234ze(E). A reference centrifugal impeller was reconstructed in ANSYS BladeGen, meshed in ANSYS TurboGrid using the Automatic Topology and Meshing method, and simulated in ANSYS CFX (2024 R2) as a single periodic passage with Frozen Rotor interfaces and Spalart–Allmaras turbulence closure. Performance maps were generated for each fluid across a range of rotational speeds and mass flow rates, with a common inlet reference condition applied across all cases to isolate the influence of fluid properties from an inlet state. The resulting dataset enables a like-for-like comparison of pressure ratio, efficiency, and shaft power requirement, providing a basis for assessing the aerodynamic implications of drop-in fluid substitution in centrifugal compression systems. Air, nitrogen, argon and carbon dioxide achieved similar peak efficiencies (~88%) and comparable pressure ratios (PR), indicating they can be used as drop-in substitutes without performance loss. Refrigerants R1234yf and R1234ze(E) matched R134a in efficiency (peak ~90%) while offering higher pressure ratios and significantly lower power requirements at peak efficiency. At 20,000 RPM and a mass flow rate of 2 kg/s, compared to a PR of 1.45 for air, nitrogen, carbon dioxide and argon achieved PRs of 1.4, 1.9 and 2.4, respectively. At the same settings, R134a and R1234 refrigerants reached PRs of 5 and 6, respectively. The power requirement was ~8 × 104 W for air and similar fluids, and ~11 × 104 W for refrigerants.

2 July 2022 in Applied Mechanics
Verified
Journal Article
Open access
PDF file
JBJames Bull
James Bull
James M. BuickJames M. Buick
James M. Buick
JRJovana Radulovic
Jovana Radulovic
Commonly, researchers have investigated many factors that impact the performance of air conditioning and refrigeration systems, such as varied cooling configurations, operating conditions and optimization of specific system components. Although there is an abundance of research detailing the importance of working fluid selection, very few studies focus on how the working fluid selection influences the performance of the individual components of the system, such as the compressor. In this paper, the performances of a selection of working fluids are compared through a centrifugal compressor using CFD. The working fluids considered are R1234ze, R1234yf, R152a, R444a, R445a, R290 and R600a and were selected due to suitability as replacements to R134a. Each fluid, including R134a, was compared based on the performance of a centrifugal compressor with fixed inlet conditions across two operational speeds. The results indicate that R1234ze and R1234yf demonstrated the best performance as replacements to R134a, achieving the highest overall pressure ratios. Additionally, R1234ze also displayed similar power required through the compressor to R134a indicating greater suitability as a drop-in replacement. The working fluids R444a and R445a both displayed performance similar to that of R134a across both operational speeds, indicating reasonable suitability as a replacement to R134a. Alternatively, R152a, R290 and R600a displayed reduced performance compared to R134a and subsequently, are not suitable replacements based on the compression system considered in this study. As well as considering the observed differences in the performance from the selected working fluids, the implications of the results for industrial applications are also considered, along with avenues for further work.